

Add to Cart
Speed 1~2.5m/s Safe And Stable High Speed Elevator / Low Noice Hospital Elevator
Warm Concern,a Beautiful Humanity World
SUNNY-Elevator.pdf
SUNNY hospital elevators are not just used in delivering
passengers. Because of its use particularity, it has special and
strict requirements to the elevator use properties. SUNNY hospital
elevator can accurately control the elevators' running speed. It
brings about the smooth and comfortable travel.
SUNNY hospital elevator lays special importance upon the humane
design. It fully optimizes the car structure. It satisfies the
clients' use requirements to the greatest extent. It creates a
peaceful and graceful space for vast passengers.
SUNNY hospital elevator satisfies the needs of emergency patients'
delivery. It applies humanization design and is equipped with a
full set of top equipments. It is smooth and comfortable in
running.
Ceiling: SN-CC-525 style stainless steel frame,
Acrylic top panel and lighting decoration
Ventilation: Axial fan
Car wall : Hairline stainless steel
Handrail: SN-CH-711
Floor: SN-CF-606
Standard
Load DL(KG) | Speed V(m/s) | Car Dimension | Hositway Dimension | Max No.of Stops | Max Travel (m) | Min Span Between Various Floors | Power KW | Distance of Bracket Guide Rail(mm) | |||||
CW(mm) | CD(mm) | OP(mm) | Min HW (mm) | Min HD (mm) | Min S (mm) | Min K (mm) | |||||||
1600 | 1 | 1400 | 2400 | 1100 (center- opening) | 2500 | 2850 | 1500 | 4300 | 20 | 60 | 2.7 | 11 | 2000 |
1.5 | 1600 | 4400 | 24 | 72 | 16.4 | ||||||||
1.75 | 1600 | 4500 | 30 | 90 | 19.2 | ||||||||
2.0 | 1700 | 4700 | 30 | 90 | 22 | ||||||||
2.5 | 2000 | 5100 | 38 | 150 | 27.5 |
Optional
Load DL(KG) | Speed V(m/s) | Car Dimension | Hositway Dimension | Max No.of Stops | Max Travel (m) | Min Span Between Various Floors | Power KW | Distance of Bracket Guide Rail(mm) | |||||
CW(mm) | CD(mm) | OP(mm) | Min HW (mm) | Min HD (mm) | Min S (mm) | Min K (mm) | |||||||
1600 | 1 | 1400 | 2400 | 1200 (side- opening) | 2400 | 2850 | 1500 | 4300 | 20 | 60 | 2.7 | 11 | 2000 |
1.5 | 1600 | 4400 | 24 | 72 | 16.4 | ||||||||
1.75 | 1600 | 4500 | 30 | 90 | 19.2 | ||||||||
2.0 | 1700 | 4700 | 30 | 90 | 22 | ||||||||
2.5 | 2000 | 5100 | 38 | 150 | 27.5 |
Note: Reference only, for detail information, please contact SUNNY
elevator.
Optional
FAQ
1. Are the elevator wire ropes durable?
The elevator wire rope has special provisions and requirements.
Configuration is not only for wire rope and rated load, but also
considered the size of the traction, as a result, the tensile
strength of wire rope is greater than the weight of the lift. The
safety factor is equipped with more than four wire rope. So it
won’t break at the same time.
2. Is it dangerous for power failure suddenly during the elevator
running?
If it occurs, the elevator will automatically stop due to the
electrical and mechanical safety device. In case of power
failure,elevator brakes will automatically taken. In addition, the
power supply departments such as planned outage, prior notice are
also operating.
3. Will us be hurt when it closed suddenly?
In the closing process, if people touch the hall door, the door of
elevator will automatically restart without any danger. With anti
clamping switch, once the gate touched, this switching action make
the elevator unable to be closed and even reopened. In addition,
closing force is also available here.
4. How the elevator running?
Elevators are operated with a counterweight wire rope through the
(tractor) traction drive, making ups and downs on the guide rail.
5. Is the escalator installation complicated?
We believe the functions of an escalator are not necessarily
proportional to the operation complexity. Therefore, escalators
designed by us apply an integrated structure, so that the equipment
is more precise and more efficient and allows easier and more
convenient commissioning.
6. Do you have any cerifications?
Yes, we do with ISO9001 / CCC / CE Certificates for u.