AC 220V Elevator Integrated Control With Parallel System For Elevator Parts
IP54 Escalator Safety Device With Travelator Control System
K-ESC2 Escalator Safety Protection Device
Features
· Micro-processor based escalator or moving walk control system
· Design for PESSRAE compliance
· Simple installation, no adjustments required and support various
brands of sensors
· Protection class: IP54
· Safety integrity level 2: SIL2
· Compliances: Lift Type Examination 2012, GB16899-2011,
GB/T20438-2006,
· IEC62061:2005, ISO22201:2009,EN115-1:2008+ A1:2010.
· Over speed protection, reversal protection, missing step
protection, handrail speed monitoring, brake operation monitoring,
inspection cover interlock, stopping distance monitoring, step
speed monitoring
K-MC2000 Escalator/Travelator Control System
· Supports VVVF or Y/△control
· Clear fault display to easily identify problems.
· Compliance: GB16899-2011, GB/T20438-2006, IEC62061:2005,
ISO22201:2009
· Supports LAN based monitoring
· Robust system noise isolation design
· Safety features: Over speed protection, Reversal protection,
Missing step protection,
· Handrail speed monitoring, Brake operation monitoring, Inspection
cover interlock,
· Stopping distance monitoring and Step speed monitoring
FAQ
1. Are the elevator wire ropes durable?
The elevator wire rope has special provisions and requirements.
Configuration is not only for wire rope and rated load, but also
considered the size of the traction, as a result, the tensile
strength of wire rope is greater than the weight of the lift. The
safety factor is equipped with more than four wire rope. So it
won’t break at the same time.
2. Is it dangerous for power failure suddenly during the elevator
running?
If it occurs, the elevator will automatically stop due to the
electrical and mechanical safety device. In case of power
failure,elevator brakes will automatically taken. In addition, the
power supply departments such as planned outage, prior notice are
also operating.
3. Will us be hurt when it closed suddenly?
In the closing process, if people touch the hall door, the door of
elevator will automatically restart without any danger. With anti
clamping switch, once the gate touched, this switching action make
the elevator unable to be closed and even reopened. In addition,
closing force is also available here.
4. How the elevator running?
Elevators are operated with a counterweight wire rope through the
(tractor) traction drive, making ups and downs on the guide rail.
5. Is the escalator installation complicated?
We believe the functions of an escalator are not necessarily
proportional to the operation complexity. Therefore, escalators
designed by us apply an integrated structure, so that the equipment
is more precise and more efficient and allows easier and more
convenient commissioning.
6. Do you have any cerifications?
Yes, we do with ISO9001 / CCC / CE Certificates for u.