12-24VDC Inductive Proximity Sensor Waterproof Proximity Sensor


Inside surge protection, reverse polarity protection

Long use-life cycle and high reliability, easy install,

enconomic price

Red LED status indication, easy to confifirm work situation

Protection structure IP67(IEC standard)

Replaceable for limit switches

Appearance and Dimension


ItemCodeDescription
1 Company codeCCompany code
2 Product nameJInductive proximity sensor
3 Shape of shellYCylinder-shaped
4 Dimension code1818=M18
5 Product typeWithoutWithout = High-end type( Light green head)
EE =Standard type(Orange head)
6 Detection distance0808=8mm

7 Output mode

KAC 2wires
LDC 2wires
PPNP 3wires
NNPN 3wires

8 Output state

ANO
BNC
CNO+NC

9 Connection

WithoutWithout: Lead wire
TPlug-in
RWiring leads Plug-in

Proper Usage


Mutual-interference

When several proximity sensors are mounted close to one another a malfunction of the sensor may be caused due to mutual interference.

Therefore, be sure to provide a minimum distance

between the two

sensors as below chart indicates.

Inflfluence by surrounding metals

When sensors are mounted on metallic panel, you must prevent the

sensors from being affected by any metallic object except target.

Therefore, be sure to provide a minimum distance as below chart

indicates.



Model


High-end type

CJY12-02NAT CJY12-02NBT CJY12-02NCT CJY12-02PAT CJY12-02PBT CJY12-02PCTCJY12-04NAT CJY12-04NBT CJY12-04NCT CJY12-04PAT CJY12-04PBT CJY12-04PCTCJY18-05NAT CJY18-05NBT CJY18-05NCT CJY18-05PAT CJY18-05PBT CJY18-05PCTCJY18-08NAT CJY18-08NBT CJY18-08NCT CJY18-08PAT CJY18-08PBT CJY18-08PCTCJY30-10NAT CJY30-10NBT CJY30-10NCT CJY30-10PAT CJY30-10PBT CJY30-10PCTCJY30-15NAT CJY30-15NBT CJY30-15NCT CJY30-15PAT CJY30-15PBT CJY30-15PCT

Standard type

CJY12E-02NAT CJY12E-02NBT CJY12E-02NCT CJY12E-02PAT CJY12E-02PBT CJY12E-02PCTCJY12E-04NAT CJY12E-04NBT CJY12E-04NCT CJY12E-04PAT CJY12E-04PBT CJY12E-04PCTCJY18E-05NAT CJY18E-05NBT CJY18E-05NCT CJY18E-05PAT CJY18E-05PBT CJY18E-05PCTCJY18E-08NAT CJY18E-08NBT CJY18E-08NCT CJY18E-08PAT CJY18E-08PBT CJY18E-08PCTCJY30E-10NAT CJY30E-10NBT CJY30E-10NCT CJY30E-10PAT CJY30E-10PBT CJY30E-10PCTCJY30E-15NAT CJY30E-15NBT CJY30E-15NCT CJY30E-15PAT CJY30E-15PBT CJY30E-15PCT
Sensing distance2mm4mm5mm8mm10mm15mm
HysteresisMax. 10% of sensing distance
Standard sensing target12×12×1mm
(Iron)
18×18×1mm
( Iron)
25×25×1mm
(Iron)
30×30×1mm
(Iron)
45×45×1mm
( Iron)
Setting distance0~1.4mm0~2.8mm0~3.5mm0~5.6mm0~7mm0~10.5mm
Power supply (Operating voltage)12-24VDC (10-30VDC)
Leakage currentMax.10mA
Response frequency (※1)1000Hz500Hz500Hz350Hz350Hz( 高端 )200Hz
400Hz( 标准 )
Residual voltage1.0V 以下 Max. 1.0V
Affection by Temp.Max. ±10% for sensing distance at ambient temperature 20℃
Control outputMax. 200mA
Insulation resistanceMin. 50MΩ(at 500VDC megger)
Dielectric strength1500VAC 50/60Hz for 1minute
Vibration1mm amplitude at frequency of 10 to 55Hz(for 1 min.) in each of X, Y, Z directions for 2 hours
Shock500m/s2(approx. 50G) X, Y, Z directions for 3 times
IndicatorOperation indicator(red LED)
Ambient temperature-25~+70℃ ( No icing)
Storage temperature-30~+80℃ (No icing)
Ambient humidity35~95%RH ( No condensation)
Protection circuitSurge protection circuit, Reverse polarity protection circuit, Overcurrent protection circuit
MaterialCase/Nut: Nickel plated Brass, Washer: Nickel plated Iron, Sensing surface: PBT
ProtectionIP65



FAQ
1. Are the elevator wire ropes durable?
The elevator wire rope has special provisions and requirements. Configuration is not only for wire rope and rated load, but also considered the size of the traction, as a result, the tensile strength of wire rope is greater than the weight of the lift. The safety factor is equipped with more than four wire rope. So it won’t break at the same time.
2. Is it dangerous for power failure suddenly during the elevator running?
If it occurs, the elevator will automatically stop due to the electrical and mechanical safety device. In case of power failure,elevator brakes will automatically taken. In addition, the power supply departments such as planned outage, prior notice are also operating.
3. Will us be hurt when it closed suddenly?
In the closing process, if people touch the hall door, the door of elevator will automatically restart without any danger. With anti clamping switch, once the gate touched, this switching action make the elevator unable to be closed and even reopened. In addition, closing force is also available here.
4. How the elevator running?
Elevators are operated with a counterweight wire rope through the (tractor) traction drive, making ups and downs on the guide rail.
5. Is the escalator installation complicated?
We believe the functions of an escalator are not necessarily proportional to the operation complexity. Therefore, escalators designed by us apply an integrated structure, so that the equipment is more precise and more efficient and allows easier and more convenient commissioning.
6. Do you have any cerifications?
Yes, we do with ISO9001 / CCC / CE Certificates for u.

China 12 - 24VDC Elevator Electrical Parts Inductive Waterproof Proximity Sensor supplier

12 - 24VDC Elevator Electrical Parts Inductive Waterproof Proximity Sensor

Inquiry Cart 0