

Add to Cart
12-24VDC Inductive Proximity Sensor Waterproof Proximity Sensor
Inside surge protection, reverse polarity protection
Long use-life cycle and high reliability, easy install,
enconomic price
Red LED status indication, easy to confifirm work situation
Protection structure IP67(IEC standard)
Replaceable for limit switches
Appearance and Dimension
Item | Code | Description |
1 Company code | C | Company code |
2 Product name | J | Inductive proximity sensor |
3 Shape of shell | Y | Cylinder-shaped |
4 Dimension code | 18 | 18=M18 |
5 Product type | Without | Without = High-end type( Light green head) |
E | E =Standard type(Orange head) | |
6 Detection distance | 08 | 08=8mm |
7 Output mode | K | AC 2wires |
L | DC 2wires | |
P | PNP 3wires | |
N | NPN 3wires | |
8 Output state | A | NO |
B | NC | |
C | NO+NC | |
9 Connection | Without | Without: Lead wire |
T | Plug-in | |
R | Wiring leads Plug-in |
Proper Usage
Mutual-interference
When several proximity sensors are mounted close to one another a malfunction of the sensor may be caused due to mutual interference.
Therefore, be sure to provide a minimum distance
between the two
sensors as below chart indicates.
Inflfluence by surrounding metals
When sensors are mounted on metallic panel, you must prevent the
sensors from being affected by any metallic object except target.
Therefore, be sure to provide a minimum distance as below chart
indicates.
Model | High-end type | CJY12-02NAT CJY12-02NBT CJY12-02NCT CJY12-02PAT CJY12-02PBT CJY12-02PCT | CJY12-04NAT CJY12-04NBT CJY12-04NCT CJY12-04PAT CJY12-04PBT CJY12-04PCT | CJY18-05NAT CJY18-05NBT CJY18-05NCT CJY18-05PAT CJY18-05PBT CJY18-05PCT | CJY18-08NAT CJY18-08NBT CJY18-08NCT CJY18-08PAT CJY18-08PBT CJY18-08PCT | CJY30-10NAT CJY30-10NBT CJY30-10NCT CJY30-10PAT CJY30-10PBT CJY30-10PCT | CJY30-15NAT CJY30-15NBT CJY30-15NCT CJY30-15PAT CJY30-15PBT CJY30-15PCT |
Standard type | CJY12E-02NAT CJY12E-02NBT CJY12E-02NCT CJY12E-02PAT CJY12E-02PBT CJY12E-02PCT | CJY12E-04NAT CJY12E-04NBT CJY12E-04NCT CJY12E-04PAT CJY12E-04PBT CJY12E-04PCT | CJY18E-05NAT CJY18E-05NBT CJY18E-05NCT CJY18E-05PAT CJY18E-05PBT CJY18E-05PCT | CJY18E-08NAT CJY18E-08NBT CJY18E-08NCT CJY18E-08PAT CJY18E-08PBT CJY18E-08PCT | CJY30E-10NAT CJY30E-10NBT CJY30E-10NCT CJY30E-10PAT CJY30E-10PBT CJY30E-10PCT | CJY30E-15NAT CJY30E-15NBT CJY30E-15NCT CJY30E-15PAT CJY30E-15PBT CJY30E-15PCT | |
Sensing distance | 2mm | 4mm | 5mm | 8mm | 10mm | 15mm | |
Hysteresis | Max. 10% of sensing distance | ||||||
Standard sensing target | 12×12×1mm (Iron) | 18×18×1mm ( Iron) | 25×25×1mm (Iron) | 30×30×1mm (Iron) | 45×45×1mm ( Iron) | ||
Setting distance | 0~1.4mm | 0~2.8mm | 0~3.5mm | 0~5.6mm | 0~7mm | 0~10.5mm | |
Power supply (Operating voltage) | 12-24VDC (10-30VDC) | ||||||
Leakage current | Max.10mA | ||||||
Response frequency (※1) | 1000Hz | 500Hz | 500Hz | 350Hz | 350Hz( 高端 ) | 200Hz | |
400Hz( 标准 ) | |||||||
Residual voltage | 1.0V 以下 Max. 1.0V | ||||||
Affection by Temp. | Max. ±10% for sensing distance at ambient temperature 20℃ | ||||||
Control output | Max. 200mA | ||||||
Insulation resistance | Min. 50MΩ(at 500VDC megger) | ||||||
Dielectric strength | 1500VAC 50/60Hz for 1minute | ||||||
Vibration | 1mm amplitude at frequency of 10 to 55Hz(for 1 min.) in each of X, Y, Z directions for 2 hours | ||||||
Shock | 500m/s2(approx. 50G) X, Y, Z directions for 3 times | ||||||
Indicator | Operation indicator(red LED) | ||||||
Ambient temperature | -25~+70℃ ( No icing) | ||||||
Storage temperature | -30~+80℃ (No icing) | ||||||
Ambient humidity | 35~95%RH ( No condensation) | ||||||
Protection circuit | Surge protection circuit, Reverse polarity protection circuit, Overcurrent protection circuit | ||||||
Material | Case/Nut: Nickel plated Brass, Washer: Nickel plated Iron, Sensing surface: PBT | ||||||
Protection | IP65 |
FAQ
1. Are the elevator wire ropes durable?
The elevator wire rope has special provisions and requirements.
Configuration is not only for wire rope and rated load, but also
considered the size of the traction, as a result, the tensile
strength of wire rope is greater than the weight of the lift. The
safety factor is equipped with more than four wire rope. So it
won’t break at the same time.
2. Is it dangerous for power failure suddenly during the elevator
running?
If it occurs, the elevator will automatically stop due to the
electrical and mechanical safety device. In case of power
failure,elevator brakes will automatically taken. In addition, the
power supply departments such as planned outage, prior notice are
also operating.
3. Will us be hurt when it closed suddenly?
In the closing process, if people touch the hall door, the door of
elevator will automatically restart without any danger. With anti
clamping switch, once the gate touched, this switching action make
the elevator unable to be closed and even reopened. In addition,
closing force is also available here.
4. How the elevator running?
Elevators are operated with a counterweight wire rope through the
(tractor) traction drive, making ups and downs on the guide rail.
5. Is the escalator installation complicated?
We believe the functions of an escalator are not necessarily
proportional to the operation complexity. Therefore, escalators
designed by us apply an integrated structure, so that the equipment
is more precise and more efficient and allows easier and more
convenient commissioning.
6. Do you have any cerifications?
Yes, we do with ISO9001 / CCC / CE Certificates for u.