High-Performance Standard Vector Control Inverter Environment Temperature -10 ℃ To 50 ℃


Product introduction

PI500 series high-performance vector control inverter is based on the company's many years of design, production, sales experience, suitable for all kinds of industrial machinery, fan& water pump drive control and heavy industry such as medium frequency grinding. Products in duct design, hardware configuration, software functions, installation design has greatly improved the customer ease of use and environmental adaptability, function optimization, application is more flexible, more stable performance, greatly improve the product reliability.


Technical data

ItemsFunctionsSpecifications
Power InputRated voltage

AC 3PH 380V(-15%)~440V(+10%)

AC 1PH 220V(-15%)~240V(+10%)

AC 3PH 220V(-15%)~240V(+10%)

Input frequency50Hz/60Hz
Allowing fluctuations

Voltage continued volatility:±10% ;

Input frequency fluctuation:±5%;

Less than 3% of voltage unbalance rate 3%;

Distortion satisfy IEC61800-2 standard

Control systemControl systemHigh performance vector control inverter based on DSP
Control methodV/F control, vector control W/O PG, vector control W/ PG
Automatic torque boost functionRealize low frequency (1Hz) and large output torque control under the V/F control mode.
Acceleration/deceleration controlStraight or S-curve mode. Four times available and time range is 0.0 to 6500.0s.
V/F curve modeLinear, square root/m-th power, custom V/F curve
Over load capabilityG type:rated current 150% - 1 minute, rated current 180% - 2 seconds F type:rated current 120% - 1 minute, rated current 150% - 2 seconds
G type:rated current 150% - 1 minute, rated current 180% - 2 seconds F type:rated current 120% - 1 minute, rated current 150% - 2 seconds
Maximum frequency1,Vector control:0 to 300Hz; 2,V/F control:0 to 3200Hz
Carrier Frequency0.5 to 16kHz; automatically adjust carrier frequency according to the load characteristics.
Input frequency resolutionDigital setting: 0.01Hz Analog setting: maximum frequency×0.1%
Start torqueG type: 0.5Hz/150% (vector control W/O PG) F type: 0.5Hz/100% (vector control W/O PG)
Speed range1:100 (vector control W/O PG) 1:1000 (vector control W/ PG)
Steady-speed precisionVector control W/O PG: ≤ ± 0.5% (rated synchronous speed) Vector control W/ PG: ≤ ± 0.02% (rated synchronous speed)
Torque response≤ 40ms (vector control W/O PG)
Torque boostAutomatic torque boost; manual torque boost(0.1% to 30.0%)
DC brakingDC braking frequency: 0.0Hz to max. frequency, braking time: 0.0 to 100.0 seconds, braking current value: 0.0% to 100.0%
Jogging controlJog Frequency Range: 0.00Hz to max. frequency; Jog Ac/deceleration time: 0.0s to 6500.0s
Multi-speed operationAchieve up to 16-speed operation through the control terminal
Built-in PIDEasy to realize closed-loop control system for the process control.
Automatic voltage regulation(AVR)Automatically maintain a constant output voltage when the voltage of electricity grid changes
Torque limit and control"Excavator" feature - torque is automatically limited during the operation to prevent frequent overcurrent trip; the closed-loop vector mode is used to control torque.
Personalization functionSelf-inspection of peripherals after power-onAfter powering on, peripheral equipment will perform safety testing, such as ground, short circuit, etc.
Common DC bus functionMultiple inverter can use a common DC bus.
Quick current limitingThe current limiting algorithm is used to reduce the inverter over current probability, and improve whole unit anti-interference capability.
Timing controlTiming control function: time setting range(0m to 6500m)

Running


Input signal


Running methodKeyboard/terminal/communication
Frequency setting10 frequency settings available, including adjustable DC(0 to 10V), adjustable DC(0 to 20mA), panel potentiometer, etc.
Start signalRotate forward/reverse
Multi-speedAt most 16-speed can be set(run by using the multi-function terminals or program)
Emergency stopInterrupt controller output
Wobbulate runProcess control run
Fault resetWhen the protection function is active, you can automatically or manually reset the fault condition
PID feedback signalIncluding DC(0 to 10V), DC(0 to 20mA)

Output Signal


Running statusMotor status display, stop, ac/deceleration, constant speed, program running status.
Fault outputContact capacity :normally closed contact 3A/AC 250V,normally open contact5A/AC 250V,1A/DC 30V.
Analog outputTwo-way analog output, 16 signals can be selected such as frequency, current, voltage and other, output signal range (0 to 10V / 0 to 20mA).
Output signalAt most 4-way output, there are 40 signals each way
Run functionLimit frequency, jump frequency, frequency compensation, auto-tuning, PID control
DC current brakingBuilt-in PID regulates braking current to ensure sufficient braking torque under no overcurrent condition.
Running command channelThree channels: operation panel, control terminals and serial communication port. They can be switched through a variety of ways.
Frequency sourceTotal 10 frequency sources: digital, analog voltage, analog current, multi-speed and serial port. They can be switched through a variety of ways.
Input terminals8 digital input terminals, compatible with active PNP or NPN input mode, one of them can be for high-speed pulse input(0 to 100 kHz square wave); 3 analog input terminals for voltage or current input.
Output terminals2 digital output terminals, one of them can be for high-speed pulse output(0 to 100kHz square wave); one relay output terminal; 2 analog output terminals respectively for optional range (0 to 20mA or 0 to 10V), they can be used to set frequency, output frequency, speed and other physical parameters.

Protection function


Inverter protectionOvervoltage protection, undervoltage protection, overcurrent protection, overload protection, overheat protection, overcurrent stall protection, overvoltage stall protection, losting-phase protection (optional), communication error, PID feedback signal abnormalities, PG failure and short circuit to ground protection.
IGBT temperature displayDisplays current temperature IGBT
Inverter fan controlCan be set
Instantaneous power-down restartLess than 15 milliseconds: continuous operation. More than 15 milliseconds: automatic detection of motor speed, instantaneous power-down restart.
Speed start tracking methodThe inverter automatically tracks motor speed after it starts
Parameter protection functionProtect inverter parameters by setting administrator Password and decoding

Display


LED/OLED display keyboard


Running informationMonitoring objects including: running frequency, set frequency, bus voltage, output voltage, output current, output power, output torque, input terminal status, output terminal status, analog AI1 value, analog AI2 value, motor Actual running speed,PID set value percentage, PID feedback value percentage.
Error messageAt most save three error message, and the time, type, voltage, current, frequency and work status can be queried when the failure is occurred.
LED displayDisplay parameters
OLED displayOptional, prompts operation content in Chinese/English text.
Copy parameterCan upload and download function code information of frequency converter, rapid replication parameters.
Key lock and function selectionLock part or all of keys, define the function scope of some keys to prevent misuse.
CommunicationRS485The optional completely isolated RS485 communication module can communicate with the host computer.

Environment Product standard


Environment temperature-10℃to 40℃ (temperature at 40 ℃to 50℃, please derating for use)
Storage temperature-20 ℃ to 65 ℃
Environment humidityLess than 90% R.H, no condensation.
VibrationBelow 5.9m/s² (= 0.6g)
Application sitesIndoor where no sunlight or corrosive, explosive gas and water vapor, dust, flammable gas,oil mist, water vapor, drip or salt, etc.
AltitudeBelow 1000m
Pollution degree2
Protection levelIP20
Product standardProduct adopts safety standards.IEC61800-5-1:2007
Product adopts EMC standards.IEC61800-3:2005
Cooling methodForced air cooling

Operating environment

1)Environment temperature -10 ℃ to 50 ℃, temperature at 40 ℃, please derating for use, derating at 3% per 1°C drop. It is not recommended to use the inverter in the environment above 50°C.

2)Prevent electromagnetic interference and keep away from sources of interference.

3)Prevent intrusion of the water droplets, steam, dust, dust, cotton wool, and metal fines.

4)Prevent intrusion of the oil, salt, and corrosive gases.

5)Avoid vibrations. The maximum amplitude can’t exceed 5.9m/s (0.6g).

6)Avoid high temperature and humidity and no rain. Relative humidity is less than 90%RH. Do not allow condensation. In spaces where corrosive gases are present, the maximum relative humidity can’t exceed 60%.

7)Altitude
8)The use of flammable, flammable, explosive gas, liquid or solid hazardous environments is prohibited.




FAQ
1. Are the elevator wire ropes durable?
The elevator wire rope has special provisions and requirements. Configuration is not only for wire rope and rated load, but also considered the size of the traction, as a result, the tensile strength of wire rope is greater than the weight of the lift. The safety factor is equipped with more than four wire rope. So it won’t break at the same time.
2. Is it dangerous for power failure suddenly during the elevator running?
If it occurs, the elevator will automatically stop due to the electrical and mechanical safety device. In case of power failure,elevator brakes will automatically taken. In addition, the power supply departments such as planned outage, prior notice are also operating.
3. Will us be hurt when it closed suddenly?
In the closing process, if people touch the hall door, the door of elevator will automatically restart without any danger. With anti clamping switch, once the gate touched, this switching action make the elevator unable to be closed and even reopened. In addition, closing force is also available here.
4. How the elevator running?
Elevators are operated with a counterweight wire rope through the (tractor) traction drive, making ups and downs on the guide rail.
5. Is the escalator installation complicated?
We believe the functions of an escalator are not necessarily proportional to the operation complexity. Therefore, escalators designed by us apply an integrated structure, so that the equipment is more precise and more efficient and allows easier and more convenient commissioning.
6. Do you have any cerifications?
Yes, we do with ISO9001 / CCC / CE Certificates for u.