Main dimensions of guide rail | ||||||||||||||
L | b1 | c | f | h1 | h2 | k | n | L2 | L3 | d | r1 | a | Standard | |
Tolerance (mm) | JG/T 5072.3-1996 | |||||||||||||
Model | ±3 | ±0.4 | ||||||||||||
TK3 | 5000 | 87±1 | ≥1.8 | 2 | 60 | 16.4 | 25 | 180 | 20 | 14 | 3 | 90° | ||
TK5 | 3 | |||||||||||||
TK8 | 100±2 | ≥4 | 4.5 | 80 | 22 | 30 | 200 | 25 | 6 | 90° | ||||
TK3A | ≥1.8 | 2.2 | 60 | 10±0.1 | 16.4 | 25 | 180 | 25 | 3 | 90° | ||||
TK5A | 3.2 | |||||||||||||
The top surface and the guide surface within 5mm at both ends of
the guide rail are allowed to have a uniform contraction slope of
not more than 0.5mm. The straightness of the top surface of the guide rail along the length of the guide rail should not be greater than 2.0mm. (See Figure 3 for details) | ||||||||||||||
Tolerance (mm) | GB/T 30977-2014 | |||||||||||||
Model | ±3 | ±0.4 | ±0.5 | ±0.3 | ||||||||||
TK3 | 5000 | 87±1 | ≥1.8 | 2 | 60 | 16.4 | 25 | 180 | 20 | 14 | 3 | 90° | ||
TK5 | 3 | |||||||||||||
TK8 | 100±2 | ≥4 | 4.5 | 80 | 22 | 30 | 200 | 25 | 6 | 90° | ||||
TK3A | 78±1 | ≥1.8 | 2.2 | 60 | 10 | 16.4 | 25 | 75 | 25 | 11.5 | 3 | 90° | ||
TK5A-1 | 3 | |||||||||||||
TK5A | 3.2 | |||||||||||||
The top surface and the guide surface within 5mm of the two ends of
the guide rail should have a slope of not more than 1:10. Technical requirements: The twist along the length of the guide rail within 5m of the top surface of the guide rail and the guide surface should not be greater than 2.0mm on the guide surfaces on both sides, and should not be greater than 2.0mm on the top guide surface. (See Figure 3 for details) |
FAQ
1. Are the elevator wire ropes durable?
The elevator wire rope has special provisions and requirements.
Configuration is not only for wire rope and rated load, but also
considered the size of the traction, as a result, the tensile
strength of wire rope is greater than the weight of the lift. The
safety factor is equipped with more than four wire rope. So it
won’t break at the same time.
2. Is it dangerous for power failure suddenly during the elevator
running?
If it occurs, the elevator will automatically stop due to the
electrical and mechanical safety device. In case of power
failure,elevator brakes will automatically taken. In addition, the
power supply departments such as planned outage, prior notice are
also operating.
3. Will us be hurt when it closed suddenly?
In the closing process, if people touch the hall door, the door of
elevator will automatically restart without any danger. With anti
clamping switch, once the gate touched, this switching action make
the elevator unable to be closed and even reopened. In addition,
closing force is also available here.
4. How the elevator running?
Elevators are operated with a counterweight wire rope through the
(tractor) traction drive, making ups and downs on the guide rail.
5. Is the escalator installation complicated?
We believe the functions of an escalator are not necessarily
proportional to the operation complexity. Therefore, escalators
designed by us apply an integrated structure, so that the equipment
is more precise and more efficient and allows easier and more
convenient commissioning.
6. Do you have any cerifications?
Yes, we do with ISO9001 / CCC / CE Certificates for u.