Three Phase Elevator Inverter Control Adjust Asynchronous Motors Speed

Brand Name:SUNNY
Certification:ISO9001
Model Number:ME280
Minimum Order Quantity:1 Pcs
Delivery Time:7 working days
Payment Terms:Western Union, T/T, L/C,Paypal
Contact Now

Add to Cart

Verified Supplier
Location: Shanghai Shanghai China
Address: 5 Floor, Building 26, No. 1555 West Jinshajiang Road, Jiading District, Shanghai
Supplier`s last login times: within 1 hours
Product Details Company Profile
Product Details

Three Phase Elevator Inverter Used To Control And Adjust The Speed Of Asynchronous Motors


ME280 Series Elevator Special Inverter

ME280 series frequency converter is a dedicated frequency converter for elevators, mainly used to control and adjust the speed of asynchronous motors. ME280 has user-programmable functions, background software monitoring, communication bus functions, rich and powerful combined functions, and stable performance


Long-life design: rich and powerful combined functions Long-life design

Rich and powerful functions: with user programmable functions and background software monitoring, communication bus functions


Specification parameter

ProjectDescription
power rangethree phase:380:3.7~90kw(P type)
frequency commanddigital setting:0.01Hz;simulation setting:highest frequencyX0.025%
control methodV/F control
torque boostAutomatic Torque Boostmanual torque boost0.1%~30.0%
V/F curveLinear, multi-point, square V/F, complete V/F separation, incomplete V/F separation
Acceleration and deceleration curveLinear or S-curve acceleration and deceleration methods; four acceleration and deceleration times, acceleration and deceleration time range 0.0~6500.0s
DC brakingDC braking start frequency:0.00Hz~maximum frequencybraking time:0.0s~36.0s,Braking action current value:0.0%~100.0%
jog controlJog frequency range:0.00Hz~50.00Hz;Jog acceleration and deceleration time range 0.0s~6500.0s
simplePLC,multi-speed operationRealize up to 16-stage speed operation through built-in PLC or control terminals
built-inPIDIt is convenient to realize the process control closed-loop control system
automatic voltage adjustment(AVR)When the grid voltage changes, it can automatically keep the output voltage stable
Overvoltage and overflow stall controlIndependent limitation of current and voltage during operation to prevent frequent overcurrent and overvoltage faults
Fast current limiting functionMinimize the overcurrent fault and protect the normal operation of the inverter
Current Limit and ControlAutomatically limit the current during operation to prevent frequent overcurrent faults
Momentary stopIn the case of instantaneous power failure, the voltage drop is compensated by the load feedback energy to keep the inverter running in a short time
fast current limitingAvoid frequent inverter overcurrent faults


FAQ
1. Are the elevator wire ropes durable?
The elevator wire rope has special provisions and requirements. Configuration is not only for wire rope and rated load, but also considered the size of the traction, as a result, the tensile strength of wire rope is greater than the weight of the lift. The safety factor is equipped with more than four wire rope. So it won’t break at the same time.
2. Is it dangerous for power failure suddenly during the elevator running?
If it occurs, the elevator will automatically stop due to the electrical and mechanical safety device. In case of power failure,elevator brakes will automatically taken. In addition, the power supply departments such as planned outage, prior notice are also operating.
3. Will us be hurt when it closed suddenly?
In the closing process, if people touch the hall door, the door of elevator will automatically restart without any danger. With anti clamping switch, once the gate touched, this switching action make the elevator unable to be closed and even reopened. In addition, closing force is also available here.
4. How the elevator running?
Elevators are operated with a counterweight wire rope through the (tractor) traction drive, making ups and downs on the guide rail.
5. Is the escalator installation complicated?
We believe the functions of an escalator are not necessarily proportional to the operation complexity. Therefore, escalators designed by us apply an integrated structure, so that the equipment is more precise and more efficient and allows easier and more convenient commissioning.
6. Do you have any cerifications?
Yes, we do with ISO9001 / CCC / CE Certificates for u.

China Three Phase Elevator Inverter Control Adjust Asynchronous Motors Speed supplier

Three Phase Elevator Inverter Control Adjust Asynchronous Motors Speed

Inquiry Cart 0