R407C Air Cooled Screw Chiller Heat Recovery Units 85 - 235 Tons

Brand Name:EuroKlimat
Certification:ISO9001, ISO14001, OHSAS18001, CRAA, CQC
Model Number:EKAS
Minimum Order Quantity:1 pcs
Delivery Time:10 working days after received your payment
Payment Terms:T/T or L/C
Contact Now

Add to Cart

Active Member
Location: Dongguan Guangdong China
Address: Euroklimat Industrial Park, Huangjiang Dongguan Guangdong China 523766
Supplier`s last login times: within 2 hours
Product Details Company Profile
Product Details

Screw air cooled water chiller total heat recovery unit 85 - 235 tons


Specifications


Model EKAS 085EKAS 095EKAS 115EKAS 125EKAS 140EKAS 150EKAS 165EKAS 180EKAS 190EKAS 200EKAS 210EKAS 225EKAS 235
Nominal cooling capacitykW284.1328.3388.0410.3473.7509.4557.3601.0636.4683.3728.2797.2819.9
USRT80.893.3110.3116.7134.7144.8158.5170.9180.9194.3207.1226.7233.1

×104

kcal/h

24.428.233.435.340.743.847.951.754.758.862.668.670.5
Nominal heating capacity*kW322.7354.7426.9431.3491.6528.6578.4623.7660.5709.1749.9813.3838.6
USRT91.8100.9121.4122.6139.8150.3164.5177.3187.8201.6213.2231.2238.4

×104

kcal/h

27.830.536.737.142.345.549.753.656.861.064.569.972.1
Total heat recovery capacitykW389.9431.7518.7540.9616.0651.4725.9779.8825.8901.6933.01007.71020.7
USRT110.9122.8147.5153.8175.2185.2206.4221.7234.8256.4265.3286.5290.2

×104

kcal/h

33.537.144.646.553.056.062.467.171.077.580.286.787.8
Cooling compressor powerkW93.1101.3123.9128.6146.1157.0171.4182.0192.8206.9207.8219.7227.4
Heating compressor powerkW95.8104.1124.1135.1153.4164.8179.9189.6200.8215.1214.2226.6232.4
Heat recovery powerkW101.0109.9131.3135.9154.5166.0181.3192.5203.8218.8219.8234.2240.6
Capacity modulation 25% ~ 100% stepless modulation
Startup type Y-Δ
Power supply 380V/3~/50Hz
RefrigerantType R22
Circuit Qty. 1111111111111
Control mode Electronic expansion valve
CompressorType Semi-closed double screw type
Qty. 1111111111111
LubricantCode EK02
Filling 13x113x113x113x119x119x123x123x123x123x123x123x123x1
FanType Spiral axial fan
Qty.No.6888101012121214141616
CapacitykW10.814.414.414.4181821.621.621.625.225.228.828.8
Air flow

×104

m3/h

12161616202024242428283232
Air side heat exchangerType Fins
Density

piece

/inch

16FPI
Heat exchanger at water side of air conditionerType Dry shell-tube type
Water flow for
cooling
m3/h48.956.566.770.681.587.695.9103.4109.5117.5125.3137.1141.0
Pressure drop of cooling waterkPa58627364666151564351567344
Water flow for
heating*
3
m /h
55.561.073.474.284.690.999.5107.3113.6122.0129.0139.9144.2
Pipe diameterinch4555588888888
Heat exchanger at the heat
recovery side
Type Plate heat exchanger    
Water flowm3/h67.174.389.293.0106.0112.0124.9134.1142.0155.1160.5173.3175.6
Pipe diameterinch3333355555555
Rated currentA153165201209237255279296313413415446457
Startup currentA250278326338388413455480505548549590594
Max. startup currentA357357478478660660749749882882882882882
DimensionsLengthmm3200410041004100500050005900590059006800680077007700
Widthmm2260226022602260226022602260226022602260226022602260
Heightmm2525252525252525252525252525252525252525252525252525
Weight of a single indoor unitTransportationkg4270450046505400570057006280640065206570682068706900
Operationkg4420465048005550585658566440656066806730700070507080


Note:
■ Rated cooling work conditions: outdoor dry bulb: 35°C; outlet water temperature: 7°C; water flow 0.172m3/(h·kW).
■ Rated heating work conditions: outdoor dry/wet bulb: 7°C/6°C; outlet water temperature: 45°C; water flow 0.172m3/(h·kW).
■ Rated working conditions for total heat recovery units: inlet/outlet water temperature of chilled water: 12°C/7°C; inlet/outlet temperature of
hot water 40°C/45°C.
■ For on-site electric wiring, see the name plate or installation menu of the unit.


More Energy Saving


The heat recovery technology improves cooling efficiency, reduces power consumption, and extends the service life of a unit. The total heat recovery technology recovers all condensate heat, saves power consumed by the fan of the heat exchanger at the air side, and reduces energy consumption by more than 15%.


One Unit for Three Purposes


One unit can be used for three purposes: cooling, heating, and free hot water. The unit can provide hot water with a temperature up to 65°C to meet guest house showering, kitchen cleaning, and factory hot water consumption requirements, thus saving investment in hot water equipment.


Less CO2 and More Environment Friendly


EK air conditioners feature a leading-edge total heat recovery technology to use waste heat, greatly save energy, and effectively mitigate the heat island effect in cities due to waste heat dissipation.


Easy Installation


The unit can be easily installed outside and requires no dedicated equipment room or operator. Free hot water is available as long as you connect the hot water pipes.

China R407C Air Cooled Screw Chiller Heat Recovery  Units 85 - 235 Tons supplier