Specifications:
Model | Indoor unit | EKCK030A | EKCK050A | |||
Outdoor unit | EKAA030AK | EKAA030ARK | EKAA050AK | EKAA050ARK | ||
Nominal cooling capacity | W | 7800 | 7800 | 12500 | 12500 | |
Nominal heating capacity | W | -- | 8000 | -- | 15000 | |
Rated input power | Cooling | W | 2550 | 2600 | 4300 | 4300 |
Heating | W | -- | 2500 | -- | 5100 | |
Rated current | Cooling | A | 12 | 12 | 7.6 | 7.6 |
Heating | A | -- | 11.5 | -- | 9.1 | |
EER | W/W | 2.82 | 2.77 | 2.79 | 2.79 | |
Energy Efficiency Rating | 3 | 4 | 4 | 4 | ||
Indoor unit | Air flow | m3/h | 1200 | 1200 | 1700 | 1700 |
Power | W | 127 | 186 | |||
Current | A | 0.58 | 0.86 | |||
Noise | dB(A) | 40 | 44 | |||
Main unit (length x width x height) | mm | 705×705×290 | 832×832×290 | |||
Panel (length x width x height) | mm | 830×830×30 | 980×980×30 | |||
Weight | kg | 31 | 41 | |||
Outdoor unit | Noise | dB(A) | 59 | 61 | ||
Weight | kg | 55 | 56 | 105 | 112 | |
Length x width x height | mm | 840×311×697 | 970×345×1255 | |||
Power supply | 220V~/50Hz | 380V/3N~/50Hz | ||||
Connector size | External diameter of liquid tube | φmm(in.) | 9.52(3/8) | 9.52(3/8) | 9.52(3/8) | 9.52(3/8) |
External diameter of air tube | φmm(in.) | 15.88(5/8) | 15.88(5/8) | 19.05(3/4) | 19.05(3/4) | |
Pipe Connecting Mode | The copper tube tulip opening is connected to the threading connector. | |||||
Water drainage pipe | φ27mm |
Note:
■ The GB 19576-2004 EER standard is applied.
■ The nominal cooling capacity is measured under the following
conditions: The indoor dry/wet bulb reads 27/19 °C and the outdoor
dry/wet
bulb reads 35/24 °C.
■ The nominal heating capacity is measured under the following
conditions: The indoor dry/wet bulb reads 20/15 °C and the outdoor
dry/wet
bulb reads 7/6 °C.
■ The sound pressure level noise is measured through test in a
semi-anechoic room. Due to environment noise and other factors in
actual
operation, the actual noise may be different from those listed in
the preceding table.
■ The preceding data shows parameters when the horizontal length of
connecting pipes between indoor and outdoor units is 5 m.
■ For details about on-site power distribution and wiring for unit
installation, see the nameplate or installation manual of the unit.
Description:
Indoor unit
1. Elegant Design
The unit features graceful panel designs to improve the aesthetic
feeling of indoor decorations
2. Flexible Design
All models use decorating panels with same dimensions, facilitating
deployment of indoor lighting systems and achieving a clean and
enjoyable indoor decoration style.
3. Super-slim Unit Body
The front panel is designed to be super slim and streamlined for
easy installation.
4. Condensed water drainage pump
A fully automatic high pressure head condensed water drainage pump
is built in. The lift can reach 750 mm, greatly facilitating
configuration of the drainage pipe.
5. Super-silent Operation
The advanced three-dimensional spiral blade design from aviation
technology is adopted to optimize the vent structure and realize
super-silent operation.
6. Washable Anti-mildew Filter with Long Effective Period
Folded filters with a long effective period can be easily washed to
keep indoor air clean.
7. Wide-Angle Circular Air Supply
The unit provides wide-angle circular air with a strong and even
current. For rooms with high ceilings, the unit can also quickly
supply air to all corners, making air in the room immediately feel
comfortable.
8. Micro-computer Control
Two control modes, including delicate wireless LCD remote
controller and wired LCD remote controller, are available. A
standard unit supports both control modes. Both controllers can
realize multiple functions, including function setting, fan speed
regulation, and on/off time setting, achieve achieving accurate
control and saving energy. In addition, multiple centralized
control systems are available.
Outdoor unit
1. The unit uses a brand efficient volute compressor, which consumes less electricity while providing the same cooling/heating capacity. The compressor features a small volume and stable running.
2. The outdoor unit produces a low noise. The system is optimized to suppress vibration and noise during operation, achieving quiet and stable unit running.
3. The unit steadily runs in cooling and heating modes in summer or winter. Cooling operation range: 18°C to 48°C. Heating operation range: -10°C to 27°C.
4. The unit normally runs within ±10% of the rated voltage.
5. The unit provides high/low voltage protection, air exhaust temperature protection, overload protection, protection against phase loss or inversion, minimum downtime protection, minimum running time protection, and so on, minimizing damage to the unit. Faults are alarmed and displayed at the first moment, facilitating troubleshooting.
6. During operation, if the power fails, the unit can automatically start once the power resumes no matter how long the power failure lasts. After starting from an exceptional power failure, the unit automatically resumes the running status before the power failure. This function is not enabled upon factory delivery. It needs to be set through DIP switches on site.
7. In case that the power supply encounters phase loss or inversion, the protection device protects the running unit. Protection against phase inversion is designed for volute compressors
8. The shell of the outdoor unit is sprayed with anti-UV and pure polyester mineral highlighter on dual sides, effectively prolonging the lifecycle of the unit.
Competitive Advantage:
The ceiling-mounted EKCK series central air conditioners use
artistic panels and have uniform dimensional design at four sides.
The installation layout is convenient and flexible. The air
conditioners supply strong and even circular air through wideangle
air outlets from four sides, quickly providing a comfortable indoor
environment. In addition, advanced air circulation design
continuously introduces fresh air from outside to build a natural
and healthy living environment. This series is ideal for office
buildings
and malls, meeting requirements for comfortable environment in
modern apartments and office buildings.