CE Certificated Programmable Aging Accelerated Weather Test Instrument
UV Accelerated Weathering Tester.pdf
Function: Meet Specifications * Meet customer requirements * Stay ahead of government regulations Prevent Field Failures * Improve quality and durability * Enhance reputation * Assure product performance Gain a Competitive Edge * Save on material costs * Expand product lines * Enter new markets * Outrun the competition |
How it Works: |
About Product:
UV Weathering Test Chamber can simulate the sun, rain spray and condensation resulting damage to testthe materials by exposure to sunlight with moisture and temperature.
This test machine can get the results of damage after several days or weeks which is equal to expose to outside for a few months. The damages include fading, discoloration, brightness down, powder, crack, blur,brittle,strength decreases and oxidation. It provides the reference with testing data for improvement of existing materials, or to assess the impact of changes in product durability and other aspects.
Designing Standard:
IEC61215, ASTM D4329,D499,D4587,D5208,G154,G53;ISO 4892-3,ISO 11507;EN 534;prEN 1062-4, BS 2782;JIS D0205;SAE J2020,ect.
Brief Introduction:
UV Accelerated Aging Chamber can provide reliable aging test data to make the exact prediction
of products’ weathering fastness(ageing resistance)., which is
conducive to sift and optimize the formula. It is used in many
industries, such as: paint, inks, resin, plastics, printing and
packaging, adhesives, auto and motorcycle industry, cosmetics,
metal, electronic, electroplating, medicine,etc.
Product specification:
Inner chamber Size | 40W×114D×38Hcm | Customized |
Outside dimension | 50W×130D×146Hcm | |
Materials | SUS#304 stainless steel ( Internal and external) | |
Temperature range | RT+10~70℃ | |
Temperature uniformity | ±1℃ | |
Temperature fluctuation | ±0.5℃ | |
Temperature control | PID SSR control | |
Humidity range: | ≥90%RH | |
Controller | Korean TEMI 880 programmable controller | |
Control mode | Balance temperature humidity control (BTHC) | |
Test cycle setting | Illumination, condensation and water spray test cycle is programmable | |
Lamp power | 40W/Piece | |
Distance from sample to lamp | 50±3mm (adjustable) | |
Centre distance between the lamp | 70mm | |
Irradiance | 1.0W/cm2 | |
Wavelength ultraviolet light | UV-A: 315-400nm | |
UV-B: 280-315nm | ||
Lamp lifetime | 1600hrs | |
Effective irradiation areas | 640×1140mm | |
Illumination temperature range | 50℃~70℃ | |
Condensation temperature range | 40℃~60℃ | |
Black panel temperature | 30℃~80℃ | |
Standard Specimen Size | 75×290mm (24pcs) or 75x150mm (48pcs), or can be customized | |
Testing time | 0~999H, adjustable | |
Power | AC220V±10%, 50/60Hz, single phase, 5KW | |
Protection system | Overload short circuit protection, over temperature protection, water lacking protection |
Methods for maintenance:
1, UV accelerated aging test equipment during operation, please
remember to be sure to keep plenty of water.
2, in the pilot phase should be to minimize the time to open the
door.
3, the working indoor sensing means, do not suffer from a strong
hitting.
4, after a long time to stop using, for re-use shall be carefully
examined water, power and the parts, and then determine the correct
boot device.
5, due to ultraviolet radiation on the staff (especially the eyes)
have a strong hazards, so the operator should minimize exposure to
ultraviolet light time (contact time should be less than 1min). The
proposed operating personnel equipped with anti-goggles and jacket.
6, the device in non-working condition, should keep it dry, the
water will run out after discharge, dry and studio housing.
7, after use, the plastic housing cover, to avoid dust intrusion.
If dust, it should be removed.
TEMI 880 Controller |
Programmable LCD controller, can do cyclic test with temp, humid, water spray and condensation. |
UV lamps |
UV-A and UV-B lamps for option |
Sample Holder |
Test specimens are mounted on both the front and back side of the UV Tester, providing a large sample capacity. Sample holder can be customized. |
Experimental method
Method 1: 8 hours of ultraviolet light, a test temperature of 60
degrees, 4 hours condensation, the test temperature of 50 degrees
Method 2: 4 hours of ultraviolet light, a test temperature of 60
degrees, 4 hours condensation, the test temperature of 50 degrees
Method 3: 8 hours of ultraviolet light, a test temperature of 50
degrees, 4 hours condensation, the test temperature of 45 degrees
Method 4: four hours of ultraviolet light, the test temperature is
50 degrees, condensing 4 hours, the test temperature of 45 degrees
Method 5: 1000 hours of ultraviolet light, the test temperature of
60 degrees
Method 6: UV light 300 hours, the test temperature of 80 degrees