Low Noise 36 Patch Sineimage Resolution Test Chart

Brand Name:3nh - SineImage
Certification:CE
Model Number:ITLDR36 50DB / ITWDR36 100DB / ITUHDR36 150DB
Minimum Order Quantity:1 Pcs
Delivery Time:1-4 Days
Payment Terms:T/T
Contact Now

Add to Cart

Active Member
Location: Shenzhen Guangdong China
Address: F/6, Block 5B, Skyworth Inno Valley, Tangtou 1st Road, Shiyan, Baoan District, Shenzhen, China.
Supplier`s last login times: within 32 hours
Product Details Company Profile
Product Details

3NH High Dynamic Range (HDR) 36 Level Test Card Transparent Test Chart


Product Description

Certificates: ISO9001:2008; CE; FCC; ROHS; TUV.


ModelITWDR36
TypeTransparent
FormatCustom Designs
Ratio16:9

Brief Introduction

1. We, 3nh-Sine Image, now is the biggest and best manufacturer of Camera Test Charts in China.

2. We can make all kinds of test charts, such as ISO12233 Resolution Charts, Distortion Charts, Greyscale Charts, 18% Netral Grey Cards, SFR Charts, Dynamic Range Charts, and so on.

3. Both transmissive and reflective are OK.

4. Any customised charts are no problem, either.

5. Our test charts definitely can match with the charts of ESSER(IE) and Imatest, no matter in accuracy or in quality.
6. Compared with ESSER(IE) and Imatest, our advantages exist on not only the much better prices but also much better delivery time.

7. More and more world famous companies have already trusted us as their long-term supplier for camera test charts.
8. These companies include HUAWEI, Apple, OPPO, vivo, O-film, DJI, GoPro, Lenovo, Samsung, LG, Suny Optics, ZTE.

9. We can make some small samples for you to check and confirm first.


This Sineimage 36-Patch Dynamic Range Test Chart Transparent has 36 low-noise density patches with density steps of approximately 0.1, for a density range of at least 3.2 (density from base to base + 3.1 minimum). A nearly circular patch arrangement ensures that vignetting has minimal effect on results. A CSV reference file with actual densities will be supplied. The chart has an active area of 197x235 mm (7.75x9.25 inches) on 203x254 mm (8x10 inch) film.

It also contains slanted edges in the center and corners with 4:1 contrast for measuring MTF. The edges have an MTF50 >= 16 cycles/mm, which is about 3 times better than the best inkjet charts. Registration marks make the regions easy to select. A neutral gray background helps ensure that the chart will be well-exposed in auto exposure cameras (compared to charts with black backgrounds, which are sometimes strongly overexposed).

It is supported by Stepchart, Multicharts, Multitest and can be used with the Dynamic Range postprocessor if several manual exposures are available. Dmax >= 3.4 is sufficient for camera phones and digital cameras with small pixel sizes, but high-end DSLRs generally have higher dynamic ranges (and also manual exposure), which makes them well suited for Dynamic Range.

This chart is produced with a high-precision LVT film recording process for the best possible density range, low noise, and fine detail.


Related Products:


1. ISO Camera Test Chart


The following is a complete product line:


ModelSpecificationSizeMaterial
NQ-10-50A0.5X10x17.8 cmphotographic paper
NQ-10-100A1X20x35.6 cmphotographic paper
NQ-10-200A2X40x71.1 cmphotographic paper
NQ-10-400A4X80x142.2 cmphotographic paper
NQ-10-800A8X160x284.4 cmphotographic paper


ENHANCED ISO 12233 RESOLUTION TEST CHART


Specification Active Area Material

1 X - 20 cm x 35.6 cm Photographic Paper

2 X - 40 cm x 71.1 cm Photographic Paper

4 X - 80 cm x 142.2 cm Photographic Paper

8 X - 160 cm x 284.4 cm Photographic Paper

0.5X - 10cm x 17.8 cm Photographic Paper



Remark: We support Any customized test charts only if you have high resolution image and size.


3. TE248 A Distortion Grid Reflectance



4. Distortion Grid Test Chart To Measure Disortion of Digital Cameras



5.ITE Grayscale Chart / Grey Scale with 11 Patched(Y=0.45)



This iso camera test chart is used to measure sharpness from slanted-edge patterns (as Spatial Frequency Response = SFR) using the Imatest SFR module. It can also measure resolution from the hyperbolic wedges using the Imatest Wedge module (a part of Rescharts).


Company Information

Shenzhen 3nh Technology Co., Ltd. is a high-tech company who specializes in researching and developping, designing and manufacturing testing and measuring instruments and equipment. We have owned a 19 years accumulation of technology and experience in color and gloss management field, since founded in 1998.

FAQ

FAQ

1. Are you the manufacturer ?

Yes, we are the manufacturer of the camera testing equipments,we also can sell the chart from other brand.

2. Could you can make OEM test chart?

Yes, according to your requirements, we can make any OEM test charts with different size.

3. Could you can make any chart from other brand?

Yes, just give us the model No. or picture about the chart.

4. Is it expensive?

Of course not. You will be surprise about the price we give you.

5.Delivery Time?

Talior-made chart: 1-2 weeks after payment; Normally Chart: 2-5 working days after apyment.

6.Why choose us?

Professional company, professional team, professional technician,professional machine, high quality low price.


China Low Noise 36 Patch Sineimage Resolution Test Chart supplier

Low Noise 36 Patch Sineimage Resolution Test Chart

Inquiry Cart 0