Model | YS6080(Pulsed xenon lamp) |
Optical Geometry | Reflectance: d/8 (SCI⪰ Include UV/Exclude UV) Transmittance: d/0 (SCI⪰ Include UV/Exclude UV); Haze(ASTM
D1003) Conforms to CIE No.15, GB/T 3978, GB 2893, GB/T 18833, ISO7724/1,
ASTM E1164, DIN5033 Teil7 |
|
|
Integrating Sphere Size | Φ 154mm |
Light Source Device | 360nm-780nm Xenon Lamp, 400nm cut-off Xenon Lamp,420nm cut-off
Xenon Lamp,460nm cut-off Xenon Lamp |
Spectrophotometric Mode | Concave Grating |
Sensor | 256 Image Element Double Array CMOS Image Sensor |
Wavelength Range | 360-780nm |
Wavelength Pitch | 10nm |
Semiband Width | 5nm |
Reflectance Range | 0~200% |
Measuring Aperture | Reflective : Φ30mm/Φ25.4mm, Φ18mm/Φ15mm, Φ10mm/Φ8mm, Φ6mm/Φ4mm; Transmissive : Φ30mm/Φ25mm;Remark: 1. Automatic identification of
switch caliber 2. Customized Configuration caliber and lens position |
|
Specular Component | Reflectance: SCI&SCE Transmittance: SCI&SCE |
|
Color Space | CIE Lab, XYZ, Yxy, LCh, CIE LUV, Hunter LAB, Munsell, s-RGB,
HunterLab, DIN, βxy |
Color Difference Formula | ΔE*ab, ΔE*uv, ΔE*94, ΔE*cmc(2:1), ΔE*cmc(1:1), ΔE*00v, ΔE(Hunter),
DIN ΔE99 |
Colorimetric Index | WI (ASTM E313, CIE/ISO, AATCC, Hunter), YI (ASTM D1925, ASTM 313), TI (ASTM E313, CIE/ISO), MI (Metamerism Index), Staining Fastness, Color Fastness, Color Strength, Opacity, Gardner Index, Pt-Co Index, 555 Index, Haze(ASTM D1003) |
|
|
|
|
Observer Angle | 2° & 10° |
Illuminants | D65, A, C, UV, D50, D55, D75, F1, F2, F3, F4, F5, F6, F7, F8, F9,
F10, F11, F12 |
Displayed Data | Spectrogram/Values, Chromaticity Values, Color Difference
Values/Graph, Pass/Fail Result, Color Offset |
Measuring Time | About 2.4s (Measure SCI & SCE about 5s) |
Repeatability | Spectral reflectance: Φ25.4mm/SCI, Standard deviation within 0.06%
(400 nm to 700 nm: within 0.05%) Chromaticity value: Φ25.4mm/SCI, Standard deviation within ΔE*ab
0.012 (When a white calibration plate is measured 30 times at 5 second intervals after white calibration) Spectral Transmittance: Φ25.4mm/SCI, Standard deviation within
0.06% (400 nm to 700 nm: within 0.06%) Chromaticity value: Φ25.4mm/SCI, Standard deviation within ΔE*ab
0.015 (When a white calibration plate is measured 30 times at 5 second intervals after white calibration) |
|
|
|
Inter-instrument Error | Φ25.4mm/SCI, Within ΔE*ab 0.12 (Average for 12 BCRA Series II color tiles) |
|
Size | 370×300×200mm |
Weight | About 9.6kg |
Power Supply | DC 24V, 3A Power Adapter |
Light Source Device Life | 5 years, more than 3 million times measurements. |
Display | 7" TFT Capacitive Screen-touch Display |
Data Port | USB & Bluetooth & Print serial port |
Data Storage | Standard 5000 Pcs, Sample 40000 Pcs |
Language | Simplified Chinese, Traditional Chinese, English, (Optional
Customized German, French and Spanish) |
Working Environment | Temperature: 0~40℃; Humidity: 0~85% (No Condensation) |
Storage Environment | Temperature: -20~50℃; Humidity: 0~85% (No Condensation) |
Standard Accessory | Power Adapter, User Guide, CD Disk(PC Software), USB cable,
Standard Calibration Board, Black Calibration Cavity, Transmission black baffle, Sample holder, 25.4 caliber, 15 caliber, 8 caliber, 4
caliber,Transmissive Test Component |
Optional Accessory | Micro-printer, Micro Aperture(4mm) transmission test clamp
component, Instrument inversion components |
Notes: The specifications are subject to change without notice. |