Residential Inline Water Flow Meter LCD Irrigation Mass Flow Measurement

Brand Name:Iflow
Certification:ISO9001, CE
Model Number:2000F
Minimum Order Quantity:negotiable
Delivery Time:1-2 weeks
Payment Terms:T/T, L/C, Western Union
Contact Now

Add to Cart

Active Member
Location: Shanghai Shanghai China
Address: Room 811-Building 143, No. 1399 Husong Road, Shanghai, China
Supplier`s last login times: within 32 hours
Product Details Company Profile
Product Details

Fixed Inline ultrasonic flowmeters by transit time multi-liquid velocity determine for slurry | effluent | sewage


General of ultrasonic flow meters

The UFM Ultrasonic flowmeters can determine the velocity of a fluid flowing in a pipe by sound waves. When it's in no flow conditions, an ultrasonic wave's frequencies are transmitted into a pipe and its reflections from the fluid are the same. When it's under flowing conditions, the frequency of the reflected wave is different due to the Doppler effect. When liquid media moves faster, the frequency shift increases linearly. The transmitter processes signals from the transmitted wave and its reflections to determine the flow rate.

The transit time type ultrasonic flowmeters can give and receive ultrasonic waves between the transducers in both the upstream and downstream in the pipe. While it's under no flow conditions, it takes the same time to travel upstream and downstream between the transducers. While it's under flowing conditions, the upstream wave will travel slower and take more time than the (faster) downstream wave. When the fluid moves faster, the difference between the upstream and downstream times increases. The transmitter processes upstream and downstream times to determine the flow rate.


Data sheet

Accuracy <1%

Flow rate 0 - 10m/s, bi-direction

Pipe diameter DN32 - DN6000 mm

Liquid temperature -30℃ - 160℃

Liquid type water, sea water, sewage, effluent, oil, alcohol, any single liquid that can

transmit ulstrasonic wave

Pipe material stainless steel, cast iron, copper, PVC, aluminum, fiber glass steel

Output one way 4-20mA, one way OCT pulse, one way replay

Input three way 4-20mA, PT1000 platinum resistor for heat measurement

Communication RS485, MODBUS

Data storage SD card

Power supply DC8-36V / AC85-264V

Protection IP65 (main body), IP68 (transducer)

Humidity <85% RH

Ambient temperature -20℃ - 60℃


Description:

The ultrasonic flowmeter is available with pipe type, clamp on and other options, it's designed for linear and bi-directional volumetric flow measurement of liquid. The measured flow datas can be output by standard analog or pulse or frequency. Through HMI user friendly operator interface, the unit can be set up for a wide range of applications. Next to actual volumetric flow measurement, the unit can be configured to perform flow totalization ( plus, minus, or sum). Measurement and output of the liquid sonic velocity can be configured too.


Optionally the unit can be set to perform one of the following additional functions:

  • Calculate and output corrected standard volumetric or mass flow using external pressure & temperature inputs
  • Batch function
  • Heat function, combining T1, T2 and volume

Metering Diagram

Flow measurement Heat measurement

Reference chart

TypeModelPipe dia (mm)TemperatureDimension (mm)
Clamp onTS-2DN15-100-30-90℃45x25x32
TM-1DN50-700-30-90℃64x39x44
TL-1DN300-6000-30-90℃97x54x53
Clamp on (high temperature)TS-2-HTDN15-100-30-90℃45x25x32
TM-1-HTDN50-700-30-90℃64x39x44
TL-1-HTDN300-6000-30-90℃97x54x53
Insertion typeTC-1DN80-6000-30-90℃190x80x55
TC-2(lengthen)DN80-6000-30-90℃335x80x55
Pipe typeG3 (π type)DN15-25-30-160℃
G2DN32/DN40-30-160℃
G3DN50-6000-30-160℃

Optional temperature transducer

SpecificationModelDiaTemp.Water cutAccuracy
Clamp-on temp. transducer Pt100CT-1>DN50-40-160℃No100+ 0.8℃
Insertion temp. Transducer Pt100TCT-1Yes
Insertion temp. Pt100 with pressurePCT-1No
Insertion temp.Pt100 for small pipe DSCT-1<DN50Yes

Industries

  • Chemicals
  • Petrochemicals
  • Oil & Gas
  • Heating, Ventilation & Air Conditioning (HVAC)
  • Power Plants
  • Water treatment

Liquid type

  • Metering of cooling water
  • Demineralisedwater
  • Control of batching and blending operations
  • Mass flow measurement
  • Allocation measurement
  • District heating
  • Irrigation
  • Energy measurement

Model Selection

IModel
YFElectromagnetic flowmeter
TFTurbine
VFVotex
LXVane wheel
TUltrasonic
E/F display modeE: compact/local display, F: remote display
Pipe DiaType (mm)
xxxx

10, 15, 20, 25, 32, 40, 50, 65, 80, 100, 125, 150, 200, 250, 300,

400, 500, 600, 800, 1000

CodeAccuracy
1+ 0.5% FS
2+ 1.0% FS
3+ 0.2% FS
CodeType
NConverter: 12 / 24 VDC, pulse output
ATransmitter: 24VDC, 4-20mA outpt
BIntelligent, Lion battery, no local display
GSmart, local display, 4-20mA output
C1Smart, local display, RS485
C2Smart, local display, HART
CodeType
SCarbon steel housing
LStainless steel housing
GHigh pressure housing
HL316L electrode
HTiTitanium electrode
HTaTantlum electrode
HCHastelloy-C electrode
L1Liquid media
L2Gas media
PPressure compensation
TTemperature compensation
PTPressure&Temp. Compensation
FPTFE liner
XRubber liner

Sample: IYF-E-0100-1-C1-S-HL-L1-F,

Magmeter, local display, Dia: 100mm, + 0.5%FS, carbon steel housing, smart, 4-20mA outpt,

RS485, 316L electrode, liquid media meter, PTFE liner


Competitive Advantage:

  • Compliance to international standards: ISO9001-2008 / GB/T19001 / MC00000-044/507
  • CE approval
  • Strict process control
  • Advanced calibration equipment
  • Engineer team
China Residential Inline Water Flow Meter LCD Irrigation Mass Flow Measurement supplier

Residential Inline Water Flow Meter LCD Irrigation Mass Flow Measurement

Inquiry Cart 0