Add to Cart
Industrial Servo Motor YASKAWA AC SERVO MOTOR SGM-04A312B 400W 2.6A Ins B
SGM-04A3MA31 |
SGM-04A3NT11 |
SGM-04A3NT12 |
SGM-04A3NT21 |
SGM-04A3S011 |
SGM-04A3SB22 |
SGM-04A3SU11 |
SGM-04AFFI11 |
SGM-04AGSU11 |
SGM-04AGSU22 |
SGM-04AW12 |
SGM-04AWG36B |
SGM-04AWNS12 |
SGM-04B312 |
SGM-04U314 |
SGM-04U3G22 |
SGM-04UW12 |
SGM-04UWB4L |
SGM-04V314 |
SGM-04V314C |
SGM-08A2FJ12 |
SGM-08A2FJ34 |
SGM-08A312 |
SGM-08A312B |
In this step the V1000 is set up for use with the motor. Make sure all protective covers have been re-attached then apply power to the V1000.
DO NOT RUN THE MOTOR.
The procedure indicated here applies for Open Loop Vector (OLV) control (A1-02 = 2). For V/f control Auto- ning, only the parameters with a ― ‖will appear. For more detail, please refer to Quick Start Guide TOEPC71060614 Section 4.7, Auto uning.
Press once until the Digital Operator shows the Auto-Tuning menu (A.Tun) then press The display will show when the Auto-Tuning procedure has been successfully completed. Please reference the V1000 Quick Start Guide or repeat the Auto-Tuning procedure again if the display shows an error message. Motor HP to kW = HP x 0.746 Example: 10HP = 10 x 0.746 = 7.46 kW .
For standard AC motors use the default setting for motor base frequency (60Hz), motor poles (4) and motor rated speed.
Motor Rated Voltage (e.g. 230 V, 460 V)
Motor Rated current (e.g. 11.0 A, 22.0 A)
Motor Base Frequency (e.g. 60.0 Hz)
Motor Poles (e.g. 4 Poles)
Motor Rated Speed (e.g. 1750 rpm)
Warning! Sudden movement hazard. The V1000 and motor may start unexpectedly during Auto-Tuning. Warning! Electric Shock Hazard. High voltage will be supplied to the motor when stationary Auto-Tuning is performed. Do not touch the motor during auto-tuning. Notice: Auto-Tuning will not function properly when a brake is engaged on the load. Ensure the motor shaft can freely rotate. Never perform an Auto- Tune with motor connected to a load.
The display will show END when the Auto-Tuning procedure has been successfully completed. Please reference the V1000 Quick Start Guide or repeat the Auto-Tuning procedure again if the display shows an error message.
This step shows how to setup up the sequence and reference method of the V1000. The sequence method determines how the V1000 drive receives its start and stop command and the reference method determines how the speed of the motor is controlled. Make sure all protective covers have been re-attached and power is turned on.
DO NOT RUN THE MOTOR.
This section may require you to change one or more V1000 parameters. Please refer to Step 5 for a detailed explanation on how to change parameters
OTHER SUPERIOR PRODUCTS
Yasakawa Motor, Driver SG- | Mitsubishi Motor HC-,HA- |
Westinghouse Modules 1C-,5X- | Emerson VE-,KJ- |
Honeywell TC-,TK- | GE Modules IC - |
Fanuc motor A0- | Yokogawa transmitter EJA- |