Add to Cart
Industrial Servopack Yaskawa Input 10.0AMPS AC Servo Drive 50/60hz
SGDB-15AN
Drive Type SGDB AC Servo Drive
Applicable motor series SGMG
Option Specification None
Modification None Rated
Output 1.5kW
Supply Voltage 200V
The SGDB Sigma Series Servopacks are Amplifiers for the Sigma
Series of AC Servos. Designed for applications requiring
multi-drives, the SGDB can be used for speed control, torque
control, and position control. A digital operator can be used to
set parameters for a Servopack.
Features
230VAC Three-Phase Input Power
Accepts an Analog Voltage Speed Reference
Three Internally Set Speeds
Compact Design
Easy Operation
Estimated Shipping Size
Dimensions: 3" x 6" x 7" (8 cm x 15 cm x 18 cm)
Weight: 1 lbs 9 oz (0.71 kg)
Application motor:
SGMAH- 02AAA41
SGMAH- 02A1A41
SGMAH- 02AAA4C
SGMAH- 02A1A4C
We are specialized in providing technical solutions and consultancy for these products.
Service, repair, replace built, rebuild, regrind, recondition, refurbish, re-manufacture, retrofit and overhaul all servo drive and motor.
Most of our standard Items are available Ex-Stock
We can provide third party services all over world.
For any other related information feel free to contact us.
SGDA-A5VS |
SGDB-02ADB |
SGDB-02ADG |
SGDB-03ADB |
SGDB-03ADG |
SGDB-03ADM |
SGDB-05AD |
SGDB-05ADG |
SGDB-07ADM |
SGDB-07ADM +SGMG-06A2BBB |
SGDB-10AD |
SGDB-10ADG |
SGDB-10ADG SGMG-09A2A |
SGDB-10ADM |
SGDB-10ADM SGDB-15AN |
SGDB-10ADS |
SGDB-15AD |
SGDB-15ADG |
SGDB-15ADG-P |
SGDB-15ADGY8 |
SGDB-15ADM |
SGDB-15ADP |
SGDB-15ADP +SGMG-13A2AB |
SGDB-15ADP+SGMP-15A314 |
SGDB-15ADS |
SGDB-15ADSY18 |
SGDB-15AN |
SGDB-15AN-P |
SGDB-15VDY104 |
SGDB-1AAD |
SGDB-1AADG |
SGDB-1AADG 1 |
SGDB-1AADGY68 |
SGDB-1EADG |
SGDB-20AD |
SGDB-20ADG |
SGDB-20ADM |
SGDB-20ADP |
SGDB-20ADS |
SGDB-20ADS /G/M+SGMS-20ACA2C/SGMS-20ACA21 |
SGDB-20ADS G |
SGDB-20ADS M |
An AC reactor or DC link choke can be used for the following:
• to suppress harmonic current.
• to smooth peak current that results from capacitor switching.
• when the power supply is above 600 kVA.
• when the drive is running from a power supply system with
thyristor converters.
Note: A DC link choke is built in to 200 V and 400 V class models
with a capacity of 22 kW and higher (HD rating).
n Drive Capacity
Make sure that the motor rated current is less than the rated
nameplate output current of the drive. When running more than
one motor in parallel from a single drive, the drive rated current
should 1.1 times larger than the total motor rated current for
all connected motors or nuisance drive faults may occur.
n Starting Torque
The overload rating of the drive determines the starting and
accelerating characteristics of the motor. Expect lower running
torque than when running the motor from line power. To get more
starting torque, use a larger drive or increase both the motor
and drive capacity.
n Emergency/Fast Stop
During a drive fault condition, a protective circuit is activated
and drive output is shut off. The motor may coast to a stop or
attempt to decelerate depending on parameter settings. If the
emergency/fast stop cannot stop the load as fast as desired, a
customer-supplied mechanical brake may be required. Test emergency
stop circuitry before putting drive into operation.
n Options
The B1, B2, +1, +2, and +3 terminals are used to connect optional
power devices. Connect only devices compatible with the
drive.
n Repetitive Starting/Stopping
Applications with frequent starts and stops often exceed 150% of
their rated current values. Heat stress generated from
repetitive high current can shorten the life span of the IGBTs. The
expected lifetime for the IGBTs is about 8 million start and
stop cycles with a 4 kHz carrier frequency and a 150% peak current.
Yaskawa recommends lowering the carrier frequency, particularly
when audible noise is not a concern. The user can also
choose to reduce the load, increase the acceleration and
deceleration times, or switch to a larger drive. This will help
keep
peak current levels under 150%. Be sure to check the peak current
levels when starting and stopping repeatedly during the
initial test run, and make adjustments accordingly
OTHER SUPERIOR PRODUCTS