Switch Amplifier KFU8-UFC-Ex1.D Frequency Converter With Trip Values

Brand Name:WTL
Certification:CE
Model Number:KFU8-UFC-Ex1.D
Minimum Order Quantity:1
Delivery Time:5-8 work days
Payment Terms:T/T, Western Union,Paypal
Contact Now

Add to Cart

Verified Supplier
Location: Shenzhen Guangdong China
Address: 23E BlockB,Lushan Building,Chunfeng Road,Luohu District,Shenzhen,518001,China
Supplier`s last login times: within 25 hours
Product Details Company Profile
Product Details
Switch Amplifier KFU8-UFC-Ex1.D Frequency Converter with Trip Values

Frequency Converter with Trip Values

1-channel isolated barrier, Universal usage at different power supplies, Input for NAMUR sensors or dry contacts, Input frequency 1 mHz ... 5 kHz, Current output 0/4 mA ... 20 mA, Relay contact and transistor output, Start-up override, Line fault detection (LFD), Up to SIL2 acc. to IEC 61508/IEC 61511


Feature:

1-channel isolated barrier
Universal usage at different power supplies
Input for NAMUR sensors or dry contacts
Input frequency 1mHz ... 5 kHz
Current output 0/4 mA ... 20mA
Relay contact and transistor output
Start-up override
Line fault detection (LFD)
Up to SIL 2 acc. to IEC 61508 /IEC 61511

Specifions:
48 V AC ... 253 V AC/20 V DC ... 90 V DC
General specifications
Signal typeDigital Input
Functional safety related parameters
Safety Integrity Level (SIL)SIL 2
Supply
Connectionterminals 23, 24
Rated voltage20 ... 90 V DC / 48 ... 253 V AC 50 ... 60 Hz
Power dissipation/power consumption≤ 2 W ; 2.5 VA / 2.2 W ; 3 VA
Interface
Programming interfaceprogramming socket
Input
Connection sidefield side
ConnectionInput I: intrinsically safe: terminals 1+, 3-
Input II: non-intrinsically safe: terminals 13+, 14-
Input Isensor acc. to EN 60947-5-6 (NAMUR) or mechanical contact
Pulse duration> 50 µs
Input frequency0.001 ... 5000 Hz
Line fault detectionbreakage I ≤ 0.15 mA; short-circuit I > 6.5 mA
Input IIstartup override: 1 ... 1000 s, adjustable in steps of 1 s
Active/PassiveI > 4 mA (for min. 100 ms) / I < 1.5 mA
Open circuit voltage/short-circuit current18 V / 5 mA
Output
Connection sidecontrol side
Connectionoutput I: terminals 10, 11, 12
output II: terminals 16, 17, 18
outout III: terminasl 19+, 20-
output IV: terminals 8+, 7-
Output I, IIsignal, relay
Contact loading250 V AC / 2 A / cos φ ≥ 0.7 ; 40 V DC / 2 A
Mechanical life5 x 107 switching cycles
Energized/De-energized delayapprox. 20 ms / approx. 20 ms
Output IIIelectronic output, passive
Contact loading40 V DC
Signal level1-signal: (L+) - 2.5 V (50 mA, short-circuit/overload proof)
0-signal: switched off (off-state current ≤ 10 µA)
Output IVanalog
Current range0 ... 20 mA or 4 ... 20 mA
Open loop voltagemax. 24 V DC
Loadmax. 650 Ω
Fault signaldownscale I ≤ 3.6 mA , upscale ≥ 21.5 mA (acc. NAMUR NE43)



Similar Models:


KFD2-UFC-Ex1.D

KFU8-UFC-Ex1.D

KFA6-DWB-Ex1.D

KFD2-DWB-Ex1.D

KFU8-UFT-Ex2.D

KFA5-DWB-Ex1.D

KFD2-SR2-Ex2.W.SM

KFD2-UFT-Ex2.D


Order Process:

Send Inquiry---Peovide Quotation---Make PI---Arrange Payment---Prepare order and goods after received the payment.

We respect every customer as our friend and we sincerely do business and make friends with them, no matter where they come from.

Scan "The QR Code" , then you can find me !!!


China Switch Amplifier KFU8-UFC-Ex1.D Frequency Converter With Trip Values supplier

Switch Amplifier KFU8-UFC-Ex1.D Frequency Converter With Trip Values

Inquiry Cart 0