Single Phase Secondary Current Injection Test Phantom Load Power Source 40 - 65 Hz

Brand Name:GFUVE
Certification:ISO
Model Number:GF101
Minimum Order Quantity:1 Set
Delivery Time:3 - 7 Days
Payment Terms:T/T,, Western Union,Paypal
Contact Now

Add to Cart

Verified Supplier
Location: Beijing Beijing China
Address: Oriental HuaRui A, No. 150 Guanzhuang Road, Chaoyang District, Beijing, 100024, China
Supplier`s last login times: within 37 hours
Product Details Company Profile
Product Details

Program-controlled Single Phase Phantom Load Power Source


It is suitable for power department, measuring department, quality control department, research units, institution of higher learning, electric energy meter, power distribution terminals, power supply management, load control, power quality, reactive power compensation device and production of the enterprise and so on. It can be as single phase voltage source, current source and phantom load.


Parameters


Electrical parameters 
Accuracy class0.05%, 0.1%
Power supplySingle phase AC 85-265V, 50/60 Hz
AC Voltage output 
Range57.7V / 100 V / 220V / 380V, Switch automatically (max 500V)
Adjustment resolution0.01%, 0.1%, 1%, 10%,
Accuracy0.05% RG
StabilityBetter than 0.01% RG / 1 min
Distortion degreeBetter than 0.1% (not capacitive load)
Load capacity40VA
Full load regulation rateLess than 0.01% RG
Full load regulation timeLess than 1ms
Temperature drift8 PPM / °C
Long-term stability60 PPM/year
AC Current output 
Range0.1A / 0.25A / 0.5A / 1A / 5A / 10A / 20A / 50A / 100A,
Switch automatically
Adjustment resolution0.01%, 0.1%, 1%, 10%,
Accuracy0.05% RG
StabilityBetter than 0.01% RG/1 min
Distortion degreeBetter than 0.1% (not capacitive load)
Load capacity40VA
Full load regulation rateLess than 0.01% RG
Full load regulation timeLess than 1mS
Temperature drift8 PPM / °C
Long-term stability60 PPM/year
Power output 
Active power accuracy0.05% or 0.1%
Reactive power accuracy0.1% or 0.2%
StabilityBetter than 0.01% RG / 1 min
Phase 
Range0°-359.99°
Adjustment resolution0.01°, 0.1°, 1°, 10°
Accuracy0.03°
Frequency 
Range40-65 Hz
Adjustment resolution0.001 Hz, 0.01 Hz, 0.1 Hz, 1Hz
Accuracy0.002 Hz
Temperature drift0.5 PPM / °C
Long-term stability4 PPM/year
Harmonic 
Harmonic times2nd-63th
Adjustment resolution0.1% (Compared with fundamental wave)
Harmonic content (Compared with fundamental wave)
Voltage≤ 40%
Current≤ 40%
Phase0°-360°
Mechanical parameters 
Dimensions (W×D×H) (mm)420x320x155
Weight (kg)12
Environmental conditions 
Operating temperature0°C to 40°C
Storage conditions-30°C to 60°C
Relative humidity≤85%

The Product Picture


China Single Phase Secondary Current Injection Test Phantom Load Power Source 40 - 65 Hz supplier

Single Phase Secondary Current Injection Test Phantom Load Power Source 40 - 65 Hz

Inquiry Cart 0