Product Details

Indoor Magnetic Instrument Current Transformer Medium Voltage


Introduction


Instrument transformers are high accuracy class electrical devices used to isolate or transform voltage or current levels. The most common usage of instrument transformers is to operate instruments or metering from high voltage or high current circuits, safely isolating secondary control circuitry from the high voltages or currents. The primary winding of the transformer is connected to the high voltage or high current circuit, and the meter or relay is connected to the secondary circuit.
Instrument transformers may also be used as an isolation transformer so that secondary quantities may be used in phase shifting without affecting other primary connected devices.
Current transformers (CT) are a series connected type of instrument transformer. They are designed to present negligible load to the supply being measured and have an accurate current ratio and phase relationship to enable accurate secondary connected metering.

PARAMETERS
Technical parameters 
StandardsIEC60044; IEC 61869; ANSI/IEEE C57.13
Rated primary current5-1500A
Rated load≤15VA
Rated frequency50Hz or 60Hz
Rated secondary current5A or 1A
Rated short-time thermal current80kA, 1S
Rated dynamic current160kA
Rated insulation level12/42/75KV
FS≤10
Mechanical parameters 
MaterialEpoxy resin
Weight (kg)25
Operating conditions 
Operating temperature-25°C to +55°C
Daily average temp<+40°C
Storage temperature-40°C to +70°C
Altitude<1000 meters
ConditionNo existence of severely begrimed, erosive and radioactive gas in the air. Permission of long-term operation under rated current.



TECHNICAL PARAMETERS


Ratied Primary Current(A)Class CombinationAccuracy class and Rated output
(VA)
Short-time thermal current
(kA/S)
Rated dynamic current
(kA)
0.2(S)0.5S10P10
5-500.2(S)/10P10
0.5/10P10
101015400I1n1000I1n
7532100
100-50045100
600-100063130
1250-150080160
500-10000.2(S)/0.5/10P1063130

Overall Dimensions