Lab Portable Meter Test Equipment High Accuracy With Automatic Testing PC Software

Brand Name:GFUVE
Certification:CE, ISO9001
Model Number:GF302D-20A
Minimum Order Quantity:1SET
Delivery Time:2weeks
Payment Terms:L/C, D/A, D/P, T/T, Western Union, MoneyGram
Contact Now

Add to Cart

Verified Supplier
Location: Beijing Beijing China
Address: Oriental HuaRui A, No. 150 Guanzhuang Road, Chaoyang District, Beijing, 100024, China
Supplier`s last login times: within 37 hours
Product Details Company Profile
Product Details

Three Phase Portable watthour meter test equipment with Automatic testing PC software


The GF302D is a powerful and Three Phase Portable watthour meter test equipment . All test values are generated absolutely synthetically with a high degree of accuracy, low phase shift and stability. The test eqipment is available in 12 A, 24A or 120 A.
The GF302D Three Phase Portable watthour meter test equipment is a lightweight and portable three phase current and voltage source based on newest technology and serves for solving this problem by simulating the required load conditions. Operation is performed by integrated 7“ touch screen or via keyboards.


Watthour meter testing. With the testing requirements of today’s advanced systems, it is essential to take advantage of the new technological features of the Multi-Amp watthour meter test equipment. No matter what size your operation, you will find that Megger offers a range of instruments for watthour meter testing from portable meter testers.


APPLICATION


It is suitable for power department, measuring department, quality control department, research units, and institutions of higher learning, and electric energy meter, power distribution terminals, power supply management, load control, power quality, reactive power compensation device and the production of enterprise etc.

FEATURES


  • Min current output 1mA
  • Predefined multiple load points
  • Reference meter and power source integration
  • User friendly menu guided operation
  • Easy verification and analysis of meter installations
  • Automatic operation without need of an external PC
  • Generation of harmonics in current and voltage up to the 51th
  • Verification of the load conditions on metering installation
  • Verification of the energy registration
  • Automatic testing mechanical meter and electronic meter error
  • Voltage, current, frequency, phase angle, power factor, harmonics can be regulated
  • 1P2W, 1P3W, 3P3W, 3P4W can be set
  • 4 quadrant measurement
  • Vector diagram display and phase sequence indication on integrated colored screen
  • Especially configured USB stick for storage of customer data and measurement results

PARAMETERS


Electrical parameters 
Accuracy0.02%, 0.05%, 0.1%
Power SupplySingle phase AC 85-265V, frequency 50/60Hz.
AC Voltage Output 
Range(U1,U2,U3)57.7V, 100V, 220V, 380V
or 69.3V, 120V, 240V, 480V( optional); max 500V
Adjustment range(0-120)%RG(1)
Adjustment fineness0.01%RG, 0.1%RG, 1%RG, 10%RG as optional.
Stability0.01%/120s
Distortion0.2% (Non-capacitive load)
Output loadeach phase 25VA
Accuracy0.05%RG or 0.02%RG
AC Current Output 
Range(I1,I2,I3)200mA, 1A, 5A, 20A; max 25A
Adjustment range(0-120)%RG
Adjustment fineness0.01%RG, 0.1%RG, 1%RG, 10%RG as optional.
Stability<0.01%/120s
Distortion≤0.2% (Non-capacitive load)
Output load25VA
Accuracy0.05%RG or 0.02%RG
Power Output  
Active power output stability<0.01%RG/120s
Reactive power output stability<0.02%RG/120s
Active power measuring accuracy0.05%RG or 0.02%RG
Reactive power measuring accuracy0.1%RG
Phase Output  
Output adjustment range0°-359.999°
Output adjustment fineness10, 1, 0.1, 0.01 as optional.
Resolution0.01°
Accuracy0.02°
Power Factor 
Adjustment range-1 ~ 0 ~ 1
Resolution0.0001
Measurement accuracy0. 0005
Frequency Output  
Adjustment range40Hz-70Hz
Output adjustment fineness5Hz, 1Hz, 0.1Hz, 0.01Hz as optional.
Resolution0.001Hz
Accuracy0.002Hz
Voltage /Current/Harmonic Setting Output
Harmonic number2-51times
Harmonic content0-40%
Harmonic phase0-359.99
Harmonic setting accuracy(10%±0.1%)RD(2)
Power Energy Measurement Error 
Active power energy0.05%RG or 0.02%RG
Reactive power energy0.1%RG
Power Pulse Output  
Power pulse typeactive pulse, reactive pulse
Active power pulse output5V, 10mA
Power Pulse Input 
Energy pulse typesupport active and reactive pulse, the highest frequency power pulse input is 180K.
Communication Port
Communication PortRS232, USB2.0
Safety
Isolation protectionIEC 61010-1:2001
Measurement Category300 V CAT III, 600 V CAT II
Degree of protectionIP20
Declaration of conformityCE certified
Mechanical parameters 
Dimensions (W×D×H) (mm)445x460x158
Weight (kg)18
(1) RG means range, the same as below;
(2) RD means the setted harmonic content, harmonic can be a single output, also multiple output.
China Lab Portable Meter Test Equipment High Accuracy With Automatic Testing PC Software supplier

Lab Portable Meter Test Equipment High Accuracy With Automatic Testing PC Software

Inquiry Cart 0