Product Details
GF302D PORTABLE THREE PHASE KWH METER TEST EQUIPMENT
The Portable Three Phase kWh Meter test equipment is used for grid
corporation of measurement and energy test center, management
department of power supply bureau, national energy measurement of
testing authorities, and also used to test each kind of
single/three phase kWh meter of industries and mining enterprises
as well as electric meter manufacturers. Meanwhile, the calibrator
also can be used as one high precision standard power source.
FEATURES
- Able to test basic error, shunt running, start, standard error
automatically and manually in single-step of single/three phase,
according to relative regulation of kWh meter.
- Able to do change test caused by voltage influence, frequency
influence and harmonic influence.
- Output of power source is speedy and stable, AC maximum output of
each phase can reach 120A in maximum.
- Voltage, current and phase position of each phase can be adjusted
in split-phase, improving the flexibility of power source.
- Frequency of each impulse input port can reach 40Hz.
- 7-inch TFT color display touch screen, English menu, simple and
convenient operation, commonly used functions and current basic
load point can be controlled in one button.
- Each meter position can provide one standard, dependent RS485 port,
and able to perform multi-function test, such as communication
test.
- Impulse port of each meter position, external polarity can be set
randomly, able to adapt kWh meter of impulse cascade and
common-anode.
PARAMETERS
Electrical parameters |
---|
Accuracy | 0.05%, 0.1% |
Power Supply | One Phase AC 180-265V, frequency 50/60Hz. |
AC Voltage Output |
---|
Range(U1,U2,U3) | 57.7V, 100V, 220V, 380V or 69.3V, 120V, 240V, 480V( optional) |
Adjustment range | (0-120)%RG(1) |
Adjustment fineness | 0.01%RG, 0.1%RG, 1%RG, 10%RG as optional. |
Stability | 0.01%/120s |
Distortion | 0.3% (Non-capacitive load) |
Output load | each phase 25VA |
Measuring accuracy | 0.05%RG |
AC Current Output |
---|
Range(I1,I2,I3) | 200mA, 1A, 5A, 20A, 100A |
Adjustment range | (0-120)%RG |
Adjustment fineness | 0.01%RG, 0.1%RG, 1%RG, 10%RG as optional. |
Stability | <0.01%/120s |
Distortion | ≤0.3% (Non-capacitive load) |
Output load | 45VA |
Accuracy | 0.05%RG |
Power Output |
---|
Active power output stability | <0.01%RG/120s |
Reactive power output stability | <0.02%RG/120s |
Active power measuring accuracy | 0.05%RG |
Reactive power measuring accuracy | 0.1%RG |
Phase Output |
---|
Output adjustment range | 0°-359.999° |
Output adjustment fineness | 10, 1, 0.1, 0.01 as optional. |
Resolution | 0.01° |
Accuracy | 0.05° |
Power Factor |
---|
Adjustment range | -1 ~ 0 ~ 1 |
Resolution | 0.0001 |
Measurement accuracy | 0. 0005 |
Frequency Output |
---|
Adjustment range | 45Hz-65Hz |
Output adjustment fineness | 5Hz, 1Hz, 0.1Hz, 0.01Hz as optional. |
Resolution | 0.001Hz |
Accuracy | 0.005Hz |
Voltage /Current/Harmonic Setting |
---|
Harmonic number | 2-51times |
Harmonic content | 0-40% |
Harmonic phase | 0-359.99 |
Harmonic setting accuracy | (10%±0.1%)RD(2) |
Power Energy Measurement Error |
---|
Active power energy | 0.05%RG |
Reactive power energy | 0.1%RG |
Power Pulse Output |
---|
Power pulse type | active pulse, reactive pulse |
Active power pulse output | 5V, 10mA |
Power Pulse Input |
---|
Energy pulse type | support active and reactive pulse, the highest frequency power
pulse input is 180K. |
Mechanical parameters |
---|
Dimensions (W×D×H) (mm) | 500x600x175 |
Weight (kg) | About 27 |
(1) RG means range, the same as below; (2) RD means the setted harmonic content, harmonic can be a single
output, also multiple output. |
Company Profile
Beijing GFUVE Instrument Transformer Manufacturer Co., Ltd. was
established in 2008. It combined design, manufacturing and sales
together as one high-tech enterprise. GFUVE Instrument Transformer
company mainly produces less than 35kV current transformer and
voltage transformer, split core ct and current clamp models etc.
GFUVE is a leader manufacturer of split core current transformer
products in China. It is professional in current transformer,
potential transformer and related accessory. The product of outdoor
split core current transformer develops very quickly in the global
market. Our company has achieved certification to ISO9001. The
products are sold to over 30 provinces in China and exported to
overseas including South America, Middle East, Southeast Asia,
Australia and Africa.
Please contact us now for further business relationship. We are
here to provide you the best service and the best product.