250MA Single Output Converter Isolated 12V 3W Hilink HLK-PM12

Brand Name:HLK or OEM
Model Number:HLK-PM12 AC DC Converters
Minimum Order Quantity:1 pcs
Delivery Time:3-5 working days
Payment Terms:L/C, T/T
Place of Origin:China
Contact Now

Add to Cart

Verified Supplier
Location: Shenzhen China
Address: building A, No.6 huanping Road, Gaoqiao community, Pingdi street, Longgang District, Shenzhen 518117
Supplier`s last login times: within 47 hours
Product Details Company Profile
Product Details
Hilink 12V 3W Single Output DC-DC Converter 3W 12V HLK-PM12 AC DC Converters Power Supplies
3W series
Model NO.Size (mm)Weight (g)Output Power (w)Output Voltage (v)Output Current (mA)Efficiency %(TYP)
HLK-PM0134*20*1520g3W560072
HLK-PM033.31000
HLK-PM099330
HLK-PM1212250
HLK-PM2424125

PCB

3W Ultra small series PCB Board
PM03L/PM01L/PM09L/PM12L/PM15L/PM24L



Description
3W ultra-small series of power module is a small volume, high efficiency module power supply.
With the global input voltage range, low temperature rise, low power consumption, high efficiency, high reliability, high security isolation and so on.
Has been widely used in smart home,automation,communications equipment, instrumentation and other industries.
Product packaging

Technology
ItemsTechnical ParametersUnitsNotes
No-load rated output voltage12.0±0.1Vdc 
Full-load tated output voltage12.0±0.2Vdc 
Short time maximum output current≥350mA 
Long time maximum output current250mA 
Voltage regulation±0.2% 
Load regulation±0.5% 
Input low voltage efficiencyVin=115Vac, Output full load≥73% 
Input high voltage efficiency3Vin=230Vac, Output full load≥73% 
Output ripple and noise (mVp-p)≤120 Rated input voltage,output full load. With 20MHz bandwidth oscilloscope, Load side 10uF and 0.1uF capacitance testmV 
Switching on/off overshoot amplitude(Rated input voltage, output plus 10% load)≤5%Vo 
Output over-current protectionOutput maximum load 110-150%A 
Output short circuit protectionDirect short circuit in normal output and automatic return to nomal operation after removal of short circuit No-damage to the whole device

Safety Characteristics:

1 Products designed to meet UL, CE safety certification requirements.
2 Safety and electromagnetic compatibility
Designed with the input of 0.5A UL certified insurance;
PCB board using double-sided copper clad plate production, material for the 94-V0 fire rating level;
Safety standards: Compliance with UL1012, EN60950, UL60950
Insulation voltage: I / P-O / P: 2500VAC
Insulation resistance :I / PO / P> 100M Ohms / 500VDC 25 ℃ 70% RH
Conduction and radiation :comply with EN55011, EN55022 (CISPR22)
Electrostatic discharge :IEC / EN 61000-4-2 level 4 8kV / 15kV
RF radiation Immunity: IEC / EN 61000-4-3 See Application Note
3 Temperature safety design
At room temperature,the capacitors of this power , the inner surface of the main converter maximum temperature does not exceed 90
℃;
Shell maximum surface temperature does not exceed 60 ℃