Mini Digital Palmtop Diagnostic Ultrasound Equipment Portable Ultrasound Scanner


Descriptions:


Characteristic:

The high resolution Ultrasonic Diagnosis Equipment, controlled by computer and equipped with digital screening converter (DSC), is characterized by its clear image, stable performance and high resolution with adopting variable aperture, multi-segment dynamic focus, large dynamic band low-noise pre-amplifier, logarithmic compression, TGC control, dynamic filter, edge enhancement and frame-related technologies etc.

A. Use advanced production technology, multi-acoustic matching, frequency bandwidth, high sensitivity.

B. Full-digital transmission techniques, the received signal focus, good resolution

C. Rich software package. It is more suitable to users’ requirements.

D. Use switching power supply, power adaptability

E. Use high-speed CMOS integrated circuits and 1.5V low voltage deviceds, low energy consumption, no hear after continuous work and high reliability.

F. The circuit boards from the machine use surface mount technology, small size, light weight, beautiful appearance

Composition:

The mode is the palm ultrasound scanner including mainframe, probe, screen and power adapter. Scanning mode is electron convex array and electron liner array.

Standard configuration: 3.5MHz R60 convex probe (80 elements)

Optional accessories: 6.5 MHz R10 tans vaginal probe (80elements),

6.5MHz linear array probe(80 elements)

Medical Image workstation software, printer, etc.

Application:

The equipment is designed as a multiple function ultrasonic product for your general and special clinical application of the check of pregnant and intrauterine contraceptive ring in family planning, gynecology and obstetrics, etc, to diagnose human liver, gallbladder, spleen, kidney, pancreas, bladder, womb and fetus.


Technical Parameters:

Scanning mode: Electron convex array scanning,

Electron linear array scanning

Electron convex array

Five display format: B, B+B, 4B, B+M, M

Image magnification: ×1.0, ×1.2, ×1.3, ×1.5, ×1.6, ×1.8, ×2.0

L-zoom: real-time partial amplification

Depth of detection: ≥180mm

Image grey scale: 256 levels; 4-stageγcorrection

Frame: 3-stage frame function

Focus: Dynamic digital electronic focus point by point

Gain control: Full gain and 8-segment TGC

Probe Conversion: probe automatic identification

Frequency for Convex : 2.0MHz, 2.5 MHz, 3.0 MHz, 3.5 MHz, 4.0 MHz, 4.5 MHz, 5.0 MHz

Note: Hospital name, age, sex; organ automatic annotation function; Partial and full-screen character annotation function.

Display: English/Chinese conversion function; Fixed characters, real-time colock, calendar display.

Human Body Mark : 15 kinds

Puncture function: puncture guide line displayed in B mode.

Measurement function: distance, CRL, GS, BPD, FL, AC, HC, APTD, APD. Image display: image freeze, real-time, up/down, left/right, black/white reverse.

Cine loop: 512-frame cine loop and storage.

Image storage: store 16 thousand image by USB flash.

Printing function: connect with laser printer or video printer

Power saving function

Output interface: USB interface, standard mini port (and trapezoidal interface), video printer interface

Print: machine can connect any video printers directly.

Equipment for the injection shell structure. The host uses non-frequency transformer switching power supply, and adopt to the programmable devices and surface mount technology (SMT). The whole machine with high degree of integration, excellent performance.


B ultrasonic diagnostic performance requirements file

performanceProbe style and standard frequency
Standard frequency of probe3.5 MHz6.5MHz
Random error of frequencyDeviation of Sound frequency and standard frequency should ≤±15%
Probe

linear,

R≥60mmconvex

linear(linear),

R≥60mm convex

R<60mm convex

(transvaginal)

Investigation depth,mm≥180≥70≥60
Axial resolution,mm

≤2 (depth≤80)

≤3 (80<depth≤130)

≤1

(depth≤50)

≤1

(depth≤40)

Lateral resolution,mm

≤3 (depth≤80)

≤4 (80<depth≤130)

≤2

(depth≤40)

≤2

(depth≤30)

Geometric position accuracy,%

crosswise≤10

Length wises≤5

crosswise≤5

Length wises≤5

crosswise≤10

Length wises≤5

Dead zone,mm≤4≤3≤4
Slice thickness,mm≤9≤5≤5
Pupil error,%≤±20≤±20≤±20
M mode time error,%≤5----
M mode distance error,%≤5----