High Resolution Veterinary Ultrasound Scanner Clear Image Stable Performance

Brand Name:STATEMED
Certification:CE
Model Number:STT3-VUS27
Minimum Order Quantity:1 set
Delivery Time:10 working days
Payment Terms:L/C, T/T, Western Union
Contact Now

Add to Cart

Active Member
Location: Beijing Beijing China
Address: Room D312,Floor 3,Building 3,Jia 2 Jinfu Road,Economic Development-area, Daxing District,Beijing,China.
Supplier`s last login times: within 47 hours
Product Details Company Profile
Product Details

High Resolution Veterinary Ultrasound Scanner Clear Image Stable Performance

1. Characteristic

The high resolution Animal Ultrasonic Diagnosis Equipment is characterized by its clear image, stable performance and high resolution with adopting variable aperture, multi-segment dynamic focus, large dynamic band low-noise pre-amplifier, logarithmic compression, TGC control, dynamic filter, edge enhancement and frame-related technologies etc.

2. Classifications

a) The scanning modes of ultrasound are electron convex array and electron liner array.

b) The Ultrasonic Diagnosis Equipment is a portable one in accordance with its structure.

3. Components of structure

The instrument is consist of mainframe, probe and monitor,. It can be connected with medical image work station, printer, and color monitor. The scanning modes are electron convex array and electron liner array. The main probe is 3.5MHz(R=60) Electronic Convex Array, the selective probe are 6.5 Electronic Convex Array(housing R=13)and7.5 MHz surface probe.

4. Operation functions of Equipment

● Four display format: B,B+B,4B,B+M,M; Image grey scale: 256 levels

● Freezing, real time, selective enlargement, upwards/downwards and left/right turnover of the image can be realized.

● 8 stage TGC adjustment.

● 5 types of body mark.(Swine, Dog,Equine, Bovine, Sheep)

● Full-screen character annotation.

● Fixed character, real time clock and calendar.

● Electron focusing, free combination of focus.

● Various probe for choice, enough to meet requirement of different animals

● Frequency Conversion: 2.0MHz – 8.0 MHz.

● Image magnification: ×1.0,×1.2,×1.5,×2.0. the utmost depth of detection is 240mm.

● Measuring: distance, perimeter, area, volume, pregnant weeks etc. Heart rate and slope can be measured under M mode.

● Built-in DSTN Processor, PAL-D and VGA video transmission, external screen monitor, colorful screen, video tape recorder, video image printer etc.

● Movie replay function, uninterrupted replay or step forward/backward replay for 256 images can be realized.

● Having the function of “flash in”,“flash out”, “dream in”, “dream out” and “USB”.

● With the optional function of 4 segments frame correlation.


5. Contraindication

The equipment can not be applied to the part where is burnt, scalded or the surface texture is damaged.

6. Standard

The equipment is designed and produced in strict accordance with GB10152-1997 B Type Ultrasonic Diagnosis Equipment, GB9706.1—1995 First Part of Medical Electric Equipment in General Requirements for Safety, GB9706.9—1997 Medical Electric Equipment: Safety of Medical Ultrasonic Diagnosis and Custodial Care Facility Special Requirements , The equipment is the B Type Ultrasonic Diagnosis Equipment at Class B, and Type B, Class I in terms of protection from shock hazard.


7. Technical Specification

The main functions of the main probe

2. 1. 1 The frequency of Electronic Convex Array probe is 3.5MHz(R=60)

2. 1. 2 Depth display: ≥190mm

2. 1. 3Resolution (vertical direction): ≤1mm (depth ≤130mm)

≤2mm(130mm<depth ≤160mm)

2. 1 .4 Resolution (cross direction) ≤2mm (depth ≤130mm)

≤3mm(130mm<depth ≤160mm)

2. 1. 5 Precision of geometric position :cross direction≤10%; vertical direction≤ 5%

2. 1. 6 Blind Zone(mm): ≤4mm

2. 1. 7 The conversional frequency points of the main probe (3.5MHz Convex Array probe) are: 2.0MHz﹑3.5 MHz﹑4.5 MHz﹑5.0 MHz﹑5.5 MHz﹑6.5 MHz﹑7.5 MHz , the detailed requirements of the conversion frequency points are as follows:

The frequency of probe (MHz)f≤2.52.5<f≤4.04.0<f≤5.05.0<f≤10
Type of probe

liner array ,

R≥60mm convex array

liner array ,

R≥60mm convex array


liner array ,

R≥60mm convex array


Superficial

R≥60mm convex array


(intra-cavityprobe )

R<60mm convex

Array)

Resolution

(Lateral direction) mm

≤3 (depth)≤130)

≤4(130<depth≤160)

≤2 (depth≤130)

≤3 (130<depth≤160)

≤2

(depth≤60)

≤1

(depth≤60)

≤1

(depth≤40)

Resolution

(Vertical direction) mm

≤1 (depth≤130)

≤2 (130<depth≤170)

≤1 (depth≤130)

≤2 (130<depth≤170)

≤1

(depth≤80)

≤1

(depth≤80)

≤1

(depth≤40)

Blind zone,mm≤4≤4≤3≤3≤5
Utmost depth display,mm≥190≥190≥120≥80≥60
Precision of geometric position,%

Lateral≤10

Vertical direction≤5

Lateral≤10

Vertical direction≤5

Lateral≤10

Vertical direction≤5

Lateral≤5

Vertical direction ≤5

Lateral≤10

Vertical direction≤5


8. Power

When AC 220V±22V or 110V±11V is changed , the equipment can also be operated as usual.

9. Working time

The continental working time for the Animal Ultrasonic Diagnosis Equipment is more than 8 hours.

10. Selective configurations

The medical image work station can be connected with the ultrasonic if the function index of the former satisfies the requirements of the standard.

11. Safety

There are 60 items of Security Detection Project adapts to the portable Ultrasound in the appendix A.


China High Resolution Veterinary Ultrasound Scanner Clear Image Stable Performance supplier

High Resolution Veterinary Ultrasound Scanner Clear Image Stable Performance

Inquiry Cart 0