12.1 Inch LCD Display Multi Parameter Monitoring System 36 * 18 * 33cm

Brand Name:STATEMED
Certification:ISO/CE
Model Number:STT15-MPM42
Minimum Order Quantity:1 set
Payment Terms:Western Union, T/T
Place of Origin:CHINA
Contact Now

Add to Cart

Active Member
Location: Beijing Beijing China
Address: Room D312,Floor 3,Building 3,Jia 2 Jinfu Road,Economic Development-area, Daxing District,Beijing,China.
Supplier`s last login times: within 47 hours
Product Details Company Profile
Product Details

Cheap price 12.1 inch LCD display 36*18*33cm Multi Parameter Monitoring System


Battery

Battery typerechargeable li-ion battery 12V/2300mAH
Recharge time≥4 hour
Use time≥120 minute

Power

Supply powerAC 220V±10% 50/60Hz±2%
power80VA
Fuse specifications and models, ratingT2.5AL/250V Φ5×20
Display modeLCD display
Alarm modeAudible and visual
Network connectionCan be expanded

ECG

LeadStandard Three leadsR,L,N, lead mode :Ⅰ,Ⅱ,Ⅲ
Standard Five leads

R,L,F,N,C,

Lead mode :Ⅰ,Ⅱ,Ⅲ,aVR,aVL,aVF,V;

Sensitivity2.5mm/mV,5mm/mV,10mm/mV,20mm/mV,erro≤±3%
Scan speed12.5,25,50mm/s three level,erro ≤±10%
Inner voice<30μVP-P
input impedance≥5MΩ
input loop current≤0.1μA
endure electrode polarizing voltage±300mV
Frequency property

diagnosis mode 0.05~130HZ

monitoring mode 0.5~40HZ

operating 1~20HZ

CMRR

Diagnosis mode ≥90dB

Monitoring mode ≥100dB

Operating mode ≥100dB

HR measurement range

Adult 15~300bpm

Neonate /pediatrics 15~350bpm

HR accuracy±2%
alarm range0~301bpm, upper and lower limit can be adjusted continuously
alarm indicatorAudial and visual alarm
protectionIsolated immunity voltage 4000V, Immunity of electronic surgical Anti-defibrillation
protection and recovery for defibrillation effectIn the monitor and the surgical model ,ECG waveforms recovery to baseline in 5S.
Electrode polarization recovery time after the fibrillationIn the monitor and the surgical mode ,ECG waveforms recovered to baseline in 10S.
measurement modeDiagnosis mode,monitoring mode,operation mode
pace marker pulse detection and suppressingwidth±2mV~±700mV
broadband0.1ms~2ms
risetime10μs~100μs
ECG signal input range-8.0mV~+8.0mV
HR sensitivity>200μV

NIBP

measurement rangeadultsystolic pressure40~270mmHg
diastolic pressure10~215mmHg
mean pressure20~235mmHg
pediatricssystolic pressure40~200mmHg
diastolic pressure10~150mmHg
mean pressure20~165mmHg
neonatesystolic pressure40~135mmHg
diastolic pressure10~100mmHg
mean pressure20~110mmHg
measurement precision±5mmHg
display unitmmHg,Kpa
alarm rangeSystolic pressure0~301mmHg,upper and lower limit can be adjusted continuously
diastolic pressure0~301mmHg,upper and lower limit can be adjusted continuously
alarm indicatorAudial and visual
measurement modeadultSingle , cycle, speedy
pediatricsSingle, cycle,speedy
neonatesingle,cycle
static pressure range0~300mmHg
static pressure precision±3mmHg
pulse measurement range40~240bpm

protection

adult

Dual hardware,software overpressure protection

300mmHg

Period measurement time interval (minute)1,3,5,10,15,30,60,90,120,180,240,480

Sp02

SpO2 measurement range

precision

0~100%

±2%(70~100% )

PR measurement range

precision

20~300 bpm

±2%

Alarm range0~100%,upper and lower limit can be adjusted continuously
Alarm indicatorAudial and visual alarm

RESP

Measurement range

adult 7~120 bpm

pediatric /neonate 7~150 bpm

precision±2bpm
impedance test range0.3~3Ω
base line impedance range200~4000Ω(50~120kHz pump-frequency)
apnea alarm time10~40s
alarm range0~121bpm, up and down limit can be adjusted continuously
alarm indicatorAudial and visual alarm


Packing:

Shipping:


A. If the quantity of the order is not very big, we could send to you by express delivery. Such as TNT, UPS, DHL, Fedex.

B. If the order is so big, we will advise you use Air Shipping or Sea Shipping through your nominated forwarder FOB China Port.

C. Freight collect if bulk shipment.

China 12.1 Inch LCD Display Multi Parameter Monitoring System 36 * 18 * 33cm supplier

12.1 Inch LCD Display Multi Parameter Monitoring System 36 * 18 * 33cm

Inquiry Cart 0