Wind Power / Photovoltaic generation Packaged Power distribution substation

Brand Name:Tianan Electric
Certification:IEC60076-1
Model Number:YBT13-40.5
Minimum Order Quantity:1 unit
Delivery Time:45 work days
Payment Terms:L/C, D/A, D/P, T/T, Western Union, MoneyGram
Contact Now

Add to Cart

Verified Supplier
Location: Ningbo Zhejiang China
Address: 3/F, Building B7 , 999 Yangfan Road,High-tech Zone, Ningbo, China 315040
Supplier`s last login times: within 25 hours
Product Details Company Profile
Product Details

Wind Power / PV Packaged Transformer Substation / Power distribution substation


Overview:

YBT13 Series PV and Wind Power Special Substation is researched by our company in order to meet the demand of wind power and photovoltaic generation, The product has novel appearance, compact structure, reliable performance, easy maintenance, etc.


Features:

1. Enclosure Structure

a. The frame of substation: channel steel and angle steel.

b. enclosure materials: cold rolled steel plate, stainless steel plate, composite color plate or aluminum alloy plate.

c. Steel plates are used to isolate each bay, and equipped with lighting device.

d. The roof: double-decked structure to prevent the heat radiation effectively.

e. Transformer room is divided into open type and closed type .The radiator is located outdoor for the open structure While the closed type structure has a separate room where an automatic air exhausting device is provided to control the temperature in transformer room.

f. Housing doors : low temperature type sealing strip which can achieve good sealing effect under low temperature environment.

g. The paint on the surface of the substation is dealt with baking varnish in high temperature so that it can delay the degradation arising from ultraviolet ray effectively.


2. HV Unit

1. Make various combinations at consumers’ requests,which are HXGT16-40.5, XGT5-40.5 and HXGT10-40.5 switchgears.

2. HXGT16-40.5 switchgear equipped with FT16-40.5R type load switch-fuse combined switch for wind power and photovoltaic power generation.

c. XGT5-40.5 switchgear equipped with VT16-40.5 circuit breaker.

d. The switchgear has the complete function for prevention of misoperation to ensure safety of operation and maintenance.

3. Transformer Unit

a. Transformer uses S11 type oil-immersed transformer or SCB11 dry type transformer.

b. Natural ventilation is good in transformer room or the temperature in transformer room can be lowered through the exhaustion of the wind with automatic control fan.

c. Soft connection is used between terminals on LV side and busbar, which can effectively protect LV bushing of the transformer from crush and oil leakage.

4. LV Unit

a. LV switchgear uses TANW1 series smart CB and TANM1 series MCCB, or the CB produced by designated manufacturer at customers’ request.

b. Curtained scheme can be designed according to the user’s requirements.

5. Distribution Network Automation unit

a. Automatic terminal equipment is TA-D20 type from Tianan Group, its design has been optimized after taking severe environment for the operation of wind power substation into consideration.

b. The product has strong ability to adapt the ambient temperature, communication function of dual fiber optic ring network, the strong ability of anti-interference, shockproof, moisture proof and anti-thunder, as well as low power loss.

c. The product has the functions of measurement control, non-battery protection, and data processing, monitoring alarms and abnormity detection and communication.

6. Uninterruptible Power Supply special for the power

a. Substation is installed TA-UP01/TA-UP02 uninterruptible power supply special for wind power produced by Tianan Group.

b. The product has strong ability to adapt the environment, resist shock and interference, and wide range of stabilivolt.


Parametres:

Item

Unit

Parameters



HV UnitSwitch TypeCombined Electrical ApparatusCircuit Breaker
Rated VoltagekV40.540.5
Rated FrequencyHz5050
Rated Main Busbar CurrentA6301250
1min Rated power Frequency Withstand Voltage To earth, Between Phases/to open gapkV95/11895/118
Lightning Impulse Withstand Voltage To earth, Between Phases/to open gapkV185/215185/215
Rated Short-time Withstand CurrentkA/s20/225/4
Rated Peak Withstand CurrentkA5063
Rated Short- circuit Making CurrentkA31.563
Rated Short-circuit Breaking CurrentkA31.525
LV UnitRated VoltageV690
Rated Main Circuit CurrentA1600~3300
Rated Limit Short-circuit Breaking CapacitykA50
Rated Operating Short-circuit Breaking CapacitykA40
Rated Short-time Withstand CurrentkA/1s40
Transformer UnitRated CapacitykVA1600~5500
Resistance Voltage%4; 4.5
Tapping Range%±2X2.5; ±5
Connected GroupY,yn0; D,yn11
EnclosureDegree of ProtectionHV RoomIP33
LV RoomIP33
Transformer RoomIP23
Sound LeveldB≤55