Low Voltage Switchboard Draw - Out Switchgear Electric Distribution Panel


Overview

GCS low voltage draw-out switchgear (hereinafter referred to as the device) is a low voltage draw-out switchgear which is designed and developed jointly by the Ministry of Power Industry and the Ministry of Machine Building together with Design Team in accordance with the requirements of competent industry department, power consumers and design unit, accords with national situation of China, has high technical index and can adapt to the development needs of power market and compete with current imported product.

Working condition

1. The ambient air temperature shall not be higher than ±40℃ and not be lower than -5℃,and the average temperature within 24h shall not be higher than +35℃. If the temperature exceeds the above value, the device shall run with reduced capacity.

2. When the air is clean, the relative humidity shall not exceed 50% at +40℃, and it may be higher at lower temperature, for example, 90% at +20℃. Then impact of condensation resulting from temperature variation should be considered.

3. The inclination of equipment shall not exceed 5° at installation. The height above sea level in the place of use may not exceed 2,000m.

4. The medium shall be free from explosive hazard and not contain the gas and conducting dust which may corrode metals and destroy the insulation.

5. The user's special requirements may be solved through consultation with the company.


Parameters

Rated voltage of main circuit( V)400, 690
Rated insulation voltage( V)690, 1000
Rated frequency( Hz)50
Rated insulation voltage( V)660( 1000)
Rated current ( A)Horizontal busbar< =4000
Vertical busbar1000
Rated short time withstand current of busbar( kA/1s)80
Rated peak withstand current of busbar( kA/0.1s)176
Power frequency testing voltage (V/1min)Main circuit2500
Auxiliary circuit1760
Busbar3-phase and 4-wireA. B. C. PEN
3-phase and 5-wireA. B. C. PE. N
Protection degreeIP3L0. IP4L0
Dimensions2200x (600 800 1000)x600(800 1000)