TL84 Multi-Lights Color Comparison Box D65
Application :
Standard light source color light box, color comparison box, color
assessment cabinet, is widely used in the field of color management
in various industries such as textiles, plastics, paints, inks,
printing and dyeing, printing, pigments, packaging, ceramics,
leather, cosmetics, etc., to accurately check the color deviation
of goods and improve product quality And market competitiveness.
Especially in cloudy and dark hours, the use of standard light
sources is particularly important for the color light box to detect
the color deviation of the goods.
Light Sources Parameters :
(1). D65 --- International-standard Artificial Daylight
Color temperature:6500K Power:20W
(2).F/A --- Comparison referential light source, Applicable to
family / hotel
Color temperature:2700K Power:40W
(3). CWF (Cool White Fluorescent)
Color temperature:4150K Power:20W
(4). TL84 --- Applicable to stores in Europe, Japan and China
Color temperature:4000K Power:18W
(5). UV ---- Ultraviolet light source
Wavelength:365nm Power:20W
Follow Standards :
GB/T7922,JIS Z8110/8724,CIE 30
Detailed Specifications :
Model | PT-6508 color comparison box (5 light sources) |
Inner Cabinet Size | 1280*590*600mm |
Outer Cabinet Size | 1310*620*800mm |
Weight | about 95kg |
Switch | touch switch |
Integrated Timer | Record and display running Time of each light source lamp. |
Light Sources | D65*2 ; CWF*2 ; TL84*2 ; UV*1 ; F/A*4 |
Power Supply | AC 220V 50HZ |
Light Sources Performance :
Operating Instructions :
1. Connect the random power cord to the light box, connect the
other end of the plug to the power supply socket, and turn on the
power (220V 50HZ).
2. Lightly press the ON/OFF button on the panel of the color
matching light box, the LCD module (with backlight) will display
the power supply, and display the name of each light source and the
cumulative use time.
3. Press D65, UV, F/A, TL84, CWF, keys to switch automatically, and
you can turn on multiple light sources at the same time (press
simultaneously). In the case of a single light source, the
displayed time is the name and use time of the corresponding light
source. In the case of multiple light sources, the name and use
time of the activated light source are displayed on the flow. The
CLR button on the keypad is used for resetting and clearing, which
is effective when a single light source is activated.
4. Place the tested product in the middle of the bottom plate of
the light box. The viewing angle is preferably a 90-degree light
source and a 45-degree line of sight. The appropriate angle can be
adjusted according to the shape of the object to be tested to
achieve the best detection effect. As shown in Figure A, the light
source is incident on the object to be inspected from
perpendicular, and the observer observes from 45 degrees.
5. Turn off the power and press the ON/OFF button. The power should
be turned off if it is not used for a long time.
6. When replacing a new lamp, please refer to the arrangement
position of the lamp in Figure B for installation. Various light
sources (tubes) have corresponding positions to install, and the
position of the lamp should not be reversed. After replacing the
old fluorescent tube, the original use time should be cleared (ie
restart the timing), the clearing method: turn on the replaced
fluorescent tube, insert a screwdriver into the center hole of the
CLR, and press this key (other The light tube usage time will not
be cleared). Note: Do not use the CLR buttons arbitrarily to avoid
resetting the timing system time by mistake.
7. The light box is equipped with six standard light sources, all
of which are installed in a fixed position of the light box, and
the position cannot be reversed.
8. The external power supply of this equipment must have a
grounding device to ensure safe use.
Color Assessment Cabinet Pictures :