Flexible Control Cable For Control&Monitoring Purposes 450 / 750V CU / XLPE / PVC IEC 60227-5

Brand Name:CTT cable
Certification:Yes
Model Number:N2XY
Minimum Order Quantity:500 meters (100 feet equals 30.48 meters)
Delivery Time:Shipped in 15 days after payment. Port: Yantian port,Shenzhen,China
Payment Terms:T/T, L/C
Contact Now

Add to Cart

Verified Supplier
Location: Shenzhen Guangdong China
Address: No.130 Jingsong 3rd road, Lisonglang Community, Gongming Street, Guangming District, Shenzhen, Guangdong, China, 518000
Supplier`s last login times: within 48 hours
Product Details Company Profile
Product Details

Flexible Control Cable For Control&Monitoring Purposes 450 / 750V CU / XLPE / PVC IEC 60227-5


Dimension& Electrical Data:

ItemCodeExplanation
Flame-proof/Nonfame-proof(omission)
characteristicsZAClass A fame-proof
ZBClass B fame-proof
ZCClass C fame-proof
WDZHalogen-free and low smoke fame retardant
IllustrationAmong the bundle-burning test class A,B,C,class A is the best.
Low-smoke halogen free cable is also classifed to class A,B,C for example WDZB
Seried codekControl cable
Insulation materialYPVC
YJXLPE
Sheath materialYLow smoke halogen free flame retardant polyolefn
VPVC fame-retardant
Shield materialPCopper wire or tinned copper wire braid
P3Composite Aluminum- plastic tape
P2Copper tape or copper- plastic tape
Armour Material22Steel tape armour and PVC sheath
23Steel tape armour and polyolefin sheath
32Winding steel wire armour PVC sheath
33Winding steel wire armour polyolefin sheath
Heat-resistant degree70The highest operating temperature is 70℃(Omission)
90The highest operating temperature is 90℃
Conductor TypeASingle conductor(class1)
B2stranded conductor(indicated in the bracket behind specifcation forA,Btype)
RMultiple threads stranded conductor(class5)
SpecifcationNo.of cores×Standard crosssection of conductor mm2

No.ofCores Cross-sec.(mm²)Reference Outer Diameter (mm)Reference Weight
(kg/km)
Maximum DC Resistance at20℃
(Ω/km)
Minimum Insulation Resistance at 90℃
(MΩ×km)
2×0.757.2462.424.51.2
2×17.670.818.11.1
2×1.58.0684.412.11.1
2×2.59.2115.37.411
2×410.2154.74.610.85
2×611.2202.33.080.7
2×1014.6331.91.830.65
3×0.757.5973.824.51.2
3×17.988518.11.1
3×1.58.47103.312.11.1
3×2.59.7143.97.411
3×410.781984.610.85
3×611.862643.080.7
3×1015.164341.830.65
4×0.758.1588.124.51.2
4×18.59102.118.11.1
4×1.59.14125.712.11.1
4×2.510.52177.57.411
4×411.73247.94.610.85
4×613.54351.53.080.7
4×1016.57549.71.830.65
5×0.758.76103.224.51.2
5×19.25120.518.11.1
5×1.59.87149.512.11.1
5×2.511.41213.27.411
5×412.76299.94.610.85
5×614.71425.53.080.7
5×1018.08669.61.830.65
7×0.759.41121.524.51.2
7×19.95143.318.11.1
7×1.510.64180.912.11.1
7×2.512.35261.47.411
7×414.45393.54.610.85
7×615.95534.43.080.7
7×1019.7847.71.830.65

No.ofCores Cross-sec.(mm²)Reference Outer Diameter (mm)Reference Weight
(kg/km)
Maximum DC Resistance at 20℃
(Ω/km)
Minimum Insulation Resistance at90℃
(MΩ×km)
8×0.7510.39140.524.51.2
8×111.01165.918.11.1
8×1.511.8209.512.11.1
8×2.514.37322.77.411
8×416.09455.64.610.85
8×617.826193.080.7
8×1022.531004.31.830.65
10×0.7511.58168.424.51.2
10×112.3199.618.11.1
10×1.513.8227212.11.1
10×2.516.1390.97.411
10×418.1555.74.610.85
10×620.5776.53.080.7
10×1025.51232.51.830.65
12×0.7511.93190.824.51.2
12×112.68227.618.11.1
12×1.514.23310.212.11.1
12×2.516.6449.77.411
12×418.68644.64.610.85
12×621.16903.63.080.7
14×0.7512.47214.524.51.2
14×113.86275.418.11.1
14×1.514.88350.312.11.1
14×2.517.39510.87.411
14×420754.14.610.85
14×622.21034.13.080.7
16×0.7513.7257.224.51.2
16×114.55306.218.11.1
16×1.515.63391.112.11.1
16×2.518.31572.97.411
19×0.7514.35292.724.51.2
19×115.2535018.11.1
19×1.516.4449.612.11.1
19×2.519.65680.47.411

No.ofCores Cross-sec. (mm²)Reference OuterDiameter (mm)Reference Weight (kg/km)MaximumDC Resistance at20℃ (Ω/km)Minimum Insulation Resistance at90℃
(MΩ×km)
24×0.7516.52360.124.51.2
24×117.6431.918.11.1
24×1.518.98557.112.11.1
24×2.522.8844.97.411
27×0.7516.85393.224.51.2
27×117.9547318.11.1
27×1.519.77630.412.11.1
27×2.523.27931.57.411
30×0.7517.4142824.51.2
30×118.56516.118.11.1
30×1.520.44688.812.11.1
30×2.524.091021.17.411
37×0.7518.6950924.51.2
37×120.35634.618.11.1
37×1.521.96824.612.11.1
37×2.525.951229.57.411
44×0.7521.2661624.51.2
44×122.7744.318.11.1
44×1.524.54969.612.11.1
44×2.529.71489.37.411
48×0.7521.59659.624.51.2
48×123.05798.418.11.1
48×1.524.931043.212.11.1
48×2.530.171604.17.411
52×0.7522.15705.124.51.2
52×123.66854.918.11.1
52×1.525.61118.912.11.1
52×2.530.991722.37.411
61×0.7523.43807.524.51.2
61×125.05981.918.11.1
61×1.527.121289.912.11.1
61×2.532.851988.57.411

Drum Data:



Certificates:

Tips:
When sending an inquiry about cables or building wires,please address the specification or parameters of cables shown as follows:
Cable name:
Flexible Control Cable For Control&Monitoring Purposes 450 / 750V CU / XLPE / PVC IEC 60227-5
Voltage: 450/750 V
Cross section: for example: 3×2.5 mm² (It means there are three conductors inside this cable and the size of each conductor is 2.5 square millimeters.)
Length: for example: 500 meters
Harbor& postcode: for example: Yantian port,Shenzhen,China. 518000
It will save you a lot of time and will also help us to prepare you an accurate quotation very quickly.Thanks!


China Flexible Control Cable For Control&Monitoring Purposes 450 / 750V   CU / XLPE / PVC  IEC 60227-5 supplier

Flexible Control Cable For Control&Monitoring Purposes 450 / 750V CU / XLPE / PVC IEC 60227-5

Inquiry Cart 0