250bpm SPO2 4AAA Medical Equipment Handheld Pulse Oximeter With Temperature

Brand Name:OEM
Certification:CE
Model Number:OEM
Minimum Order Quantity:1pcs
Delivery Time:2-3 days
Payment Terms:T/T, Western Union
Contact Now

Add to Cart

Verified Supplier
Location: Shenzhen Guangdong China
Address: 4th-5th Floor,Building 3,19th North Danzi Road,Kengzi Street,Pingshan Dist,Shenzhen,China
Supplier`s last login times: within 22 hours
Product Details Company Profile
Product Details

Handheld pluse oximeter with temperature LCD display CE approved


Parameter Specifications


SpO2


Patient: adult, child
Range: 35%~ 100%
Resolution: 1%
Accuracy: (70%-100%)
2% Normal
3% Motion or low perfusion
Below 70% not specified


PR


Range: 25bpm~ 250bpm
Resolution: 1bpm
Accuracy: (25-250bpm)
2bpm Normal
3bpm Motion or low perfusion


Temperature


Channel:1
Measuring and Alarm Range: 18~ 45℃
Resolution: 0.1℃
Accuracy: 0.1℃
Actualization interval: about 1 Sec
Average Time Constant: 〈10 Sec


Feature


2.8 inch color TFT LCD display for SPO2&PR.Silicon rubber shell for easy protection.Compatible with SPO2 Sensor.USB port support download test results to computer.Automatically switch off within 3 minutes when no signal.Adjust the parameters in friendly menu.Inner Flash memory can store testing result up 90 hours.Stable bracket for table usage.Visual and sound alarm function.Support 4*AA Alkaline battery and rechargeable Li battery.Low Battery voltage indicator.
Specifications
Display Mode: 2.8" Color LCD display display


SpO2


Measuring Range: 35%-100%
Accuracy: 2% (80%~100%), 3% (70%~80%), unspecified (<70%)
Pulse rate (PR)
Measurement range: 25-250 BPM
Accuracy: 2BPM
Because of the aviation restrictions, batteries are not included in the package, please use alkaline battery or Li battery to run it.
Instructions for use
Select a suitable site for the sensor, for example the animal's ear. Alternative sites recommended are claw, hands or arms.Fit the sensor as illustrated on right. the animal's claw must inserted right to the end of the sensor. Direct the cable along the patient's claw and parallel to the arm. Affix with adhesive tape if required.Connect the sensor cable to the monitor or the patient cable and verify proper operation as described in the instrument's operator manual.


Standard Accessory

Handheld Pulse Oximeter unit: 1 pcs

Adult Clip SpO2 Sensor: 1pcs

USB Cable: 1pcs

CD Software (User Manual, PC software): 1pcs


Optional Accessory

Adult Soft tip SpO2 sensor: 1pcs

Child finger clip SpO2 sensor: 1pcs

Child soft tip SpO2 sensor: 1pcs

Neonate Wrap SpO2 sensor: 1pcs

Skin Surface Temperature Probe: 1pcs


China 250bpm SPO2 4AAA Medical Equipment Handheld Pulse Oximeter With Temperature supplier

250bpm SPO2 4AAA Medical Equipment Handheld Pulse Oximeter With Temperature

Inquiry Cart 0