Mainstream EtCO2 Sensor, ETCO2 Monitor

Product Description

Mainstream EtCO2 Sensor is a plug and play mainstream CO2 sensor for Clinical End tidal Carbon Dioxide Monitoring. adopts NDIR (non-dispersive infrared) technology for real time CO2 concentration, respiration rate, end-tidal CO2 value and inspired CO2 concentration . Its professional dewater method reduced disturb from the vapor.


PRODUCT FEATURES:

  • Response is faster and less chance of erroneous
  • Dual wavelength ,proprietary sample cell protects internal ndir components from contamination
  • Barometer
  • No pumping or pneumatic components to replace Maintenance requirements and overall cost-ofownership are minimized.
  • No calibration required
  • Compatible for Phasein IRMA/ HP Respironics CAPNOSTAT 5/CPT
  • Private label option TTL/RS232,LEMO 8 pins/DB9
  • Unique accessories & supplies for all patients

Technical Specifications
Transducer TypeMainstream CO2 Sensor
Sample Rate50 mL/min, ±10mL/min.
Principle of OperationNon-dispersive infrared (NDIR) single beam optics, dual wavelength, no moving parts
Initialization TimeCapnogram displayed in less than 4 seconds
full specifications within 2 minutes
CO2 Measure Range0 - 114 mmHg
0 - 15%
0 - 15.2kPa
CO2 Resolution0.1 mm Hg 0 to 59 mm Hg
0.25 mm Hg 60 to 114 mm Hg
CO2 Accuracy0 – 40mm ±2 mmHg
41 – 76 mmHg ±5% of reading
77 – 114 mmHg ±8% of reading
Above 80 BPM ± 1 2 % o f r e ading
CO2 StabilityDrift over four hours shall not exceed 1 mmHg maximum
Accuracy specification will be maintained over a 120-hour period
Sampling Frequency100 Hz
Respiration Rate Range2 to 150 Breaths Per Minute (BPM)
Respiration Rate Accuracy±1 breath
CompensationsAutomatic Barometric pressure 400 mmHg to 800 mmHg
Operator selectable O2, N2O, He and agent compensation
CalibrationNo routine user calibration required.
Voltage Requirements5.0 VDC ±5%
Power ConsumptionLess than 1.2 Watts typical (Steady State)
Up to 2 Watts maximum on power up (Warm up)
InterconnectionStandard
Pin out:
1. VA 5.0V
2.Shield Shield
3.DGND Digital return
4. VSRC 5.0V
5.TxD Serial data from Sensor
6.RxD Serial data from Host
7. AGND Analog return
8.SYNC Unused
Data InterfaceRS232, bi-directional, 19200 baud rate, standard N-8-1.
Data OutputCO2 gas concentration(mmHg), End-tidal CO2 , Inspired CO2 , Respiratory Rate.
Gas and barometric pressure compensated when supplied by host.
Temperature and HumidityOperating: 0 to 45℃, 10 to 90% RH, non-condensing
Storage: -40 to 70℃, <90% RH, non-condensing
Water ResistanceIPX4 – Splash-proof (sensor head only)