2 Layers Anti - Corrosion PVC Roof Tiles Heat Shield Thermal Insulation

Brand Name:Yiquan
Certification:ISO9001
Model Number:Y1130-082
Minimum Order Quantity:1000 m2
Delivery Time:Within 10 Days After The Payment
Place of Origin:China
Contact Now

Add to Cart

Verified Supplier
Address: Gaohai Industrial Park, Jinsha, Nanhai District
Supplier`s last login times: within 1 hours
Product Details Company Profile
Product Details

2 Layers Anti-Corrosion Heat Shield Thermal Insulation Plastic PVC Roof Tiles


SPECIFICATION:


NameTrapezoid synthetic resin pvc roof sheets
CodeTrapezoid 1000
Materialsynthetic resin
Surface materialasa coated, color stable
Thickness3mm
Width1000mm
Effect width930mm
Wave space232.5mm
Pitch height40mm
Colorblue, gray or customized

Load Capacity:


Container Load capacityThicknessSQ.M./20 FCL (21 Tons)SQ.M./20 FCL (26 Tons)
1.0mm11000 m213600 m2
1.5mm7200 m29000 m2
1.8mm6100 m27600 m2
2.0mm5500 m26800 m2
2.5mm4300 m25400 m2
3.0mm3600 m24500 m2

Installation:


PVC tile installation should choose appropriate purlin spacing to prevent deformation cracking.
Water leakage ,specific reference to the following:
•The thickness of the pvc roof tiles is≤1.3mm to use the purling space≤600mm.
the circular arch roof to use for the purling space≤700mm.the thickness between
1.3mm to 1.8mm of the tiles need to use for purling space ≤700mm.
the arched back roof to be ≤800mm.the thickness 1.8mm to 3mm of roof sheet to
use for the purling space as ≤800mm and circular arch style to use purling space≤900mm
•The installation of the corrugated pvc roof sheet have to cover two pitch of the sheet area on
the width and the trapezium pvc roof sheet to cover one pitch on the width and to cover >250mm on the length.
•If use tapping screw that need to drill a hole with ratio 2-3mm first.

Why choose us?


1. Is apvc Roofing sheet warranted?

the professional roofing sheet manufacturer, Apvc Roofing sheet provide 10~30 years warranty depends on different kinds of products.


2. What kind of structure frame can support the plastic roof tile?

APVC Roofing sheet can be install in the wooden structure and steel structure frame.


3. Does APVC Roofing sheet test via international testing company?

All apvc products have already tested from famous international testing company-SGS to make sure the high quality products.


4. Can you meet the large order in fast delivery time?

As we are the one of large manufacturer of plastic roofing sheet, we have 11 production can output 26000 m2 per day. So we can meet the large order make the very fast delivery time.


5. How may days to install 1000m2 ?

As APVC Roofing sheet is big size and can be install easily, usually 4 people can install 600 m2 per day. It take 2 days to install 1000m2.


6. Which countries is the most popular for APVC Roofing Sheet?
As Apvc Roofing Sheet have good heat insulation, excellent anti-corrosion, long life time, so it is hot sale in Thailand, Indonesia, Saudi Arabia, Libya, Kenya, Africa and Latin American counties etc..