Efficiency = 98% 48V Solar Power Inverter Hybrid Off Grid For PV System
Product Description:
CNS110 Series Hybrid Inverter is designed to serve as a backup power supply for AC loads. The input power of CNS110 Series hybrid inverter comes from PV system and AC grid which not only supply power to AC loads but also charge the battery bank when the power from AC grid or AC generator is present(also known as Line Mode).
In the event of the AC grid (or AC generator) outage, the AC loads can be alternatively powered by PV system(if the illumination is sufficient) and the battery bank.
Key Features:
1. Compatible to mains or generator power
2. AC and solar charger
3. Wide dc input votlage 80-270vac
4. Compatible to mains or generator power
5. Selectable AC or solar priority function6. Adjustable charging
current
6. Generator restart signal
7. 3 times peak power
8. CNS110 1-12KW LCD display can show Solar generation and Inverter
parameters, while GW plus 1-12kw can only show inverter
parameters..
Application:
CONSNANT 1-12kw power inverter off grid solar inverter hybrid inverter can work with solar energy, generator and AC mains. They are widely used for home appliances and office devices for long time backup.
Specifications:
Model | CNS110 1KW-12KW | ||
Line Mode Specification: | LV Model(1-6KW) | HV Model(1-12KW) | |
Input Voltage | Input Voltage Waveform | Sinusoidal(utility or generator) | |
Nominal Input Voltage | LV 12Vac | HV 230Vac | |
Low Line Disconnect | Normal:85Vac±4% | Normal: 184 Vac±4% | |
Wide: 80 Vac±4% | Wide: 135 Vac±4% | ||
Low Line Reconnect | Normal:95Vac±4% | Normal:194Vac±4% | |
Wide: 85 Vac±4% | Wide: 145Vac±4% | ||
High Line Disconnect | Normal:136Vac±4% | Normal:263Vac±4% | |
Wide: 140 Vac±4% | Wide: 263Vac±4% | ||
High Line Reconnect | Normal:131Vac±4% | Normal:253Vac±4% | |
Wide: 135 Vac±4% | Wide: 253 Vac±4% | ||
Max AC Input Voltage | 150V rms | 270V rms | |
Input Frequency | Nominal Input Frequency | 50Hz/60Hz(Auto detection) | |
Low Line Frequency Re-connect | 51+0.3Hz for 60Hz; 41+0.3Hz for 50Hz; | ||
Low Line Frequency Disconnect | 50+0.3Hz for 60Hz; 40+0.3Hz for 50Hz; | ||
High Line Frequency Reconnect | 64+0.3Hz for 60Hz; 54+0.3Hz for 50Hz; | ||
High Line Frequency Disconnect | 65+0.3Hz for 60Hz; 55+0.3Hz for 50Hz; | ||
Main Function | Output Voltage Waveform | As same as input waveform | |
Over-load Protection(SMPS load) | Air switch | ||
Output Short Circuit Protection | Air switch | ||
Max Bypass Overload Current | 40A/50A |