Hybrid Off Grid Solar Power Inverter 24V / 48V 1 - 12kw 50 / 60Hz Customized

Brand Name:CONSNANT
Certification:CE, ISO9001, ISO14001
Model Number:CNS110
Minimum Order Quantity:10
Delivery Time:5-7 days for sample order, 7-15 days for mass production
Payment Terms:T/T, L/C, Western Union
Contact Now

Add to Cart

Verified Supplier
Location: Shenzhen Guangdong China
Address: Building B6, Junfeng Industrial Park, Fuyong Town, Bao'an District, Shenzhen City, 518103 P.R.China
Supplier`s last login times: within 48 hours
Product Details Company Profile
Product Details

Hybrid Off Grid Solar Power Inverter 24V / 48V 1 - 12kw 50 / 60Hz Customized


Description:


CNS110 Series Hybrid Inverter is designed to serve as a backup power supply for AC loads. The input power of CNS110 Series hybrid inverter comes from PV system and AC grid which not only supply power to AC loads but also charge the battery bank when the power from AC grid or AC generator is present(also known as Line Mode).

In the event of the AC grid (or AC generator) outage, the AC loads can be alternatively powered by PV system(if the illumination is sufficient) and the battery bank.


Features:


1. AC/Solar Charging Off Grid Hybrid Inverter.

2. LED/LCD display, Enhanced functions setting via LCD, Man-machine intelligent design

3. Built-in 40A/60A optional MPPT solar charger controller.

4. LCD shows the solar capacity.

5. 5 stages adjustable AC charging current. AC charging also can be closed

6. AC/DC priority modes can be set.

7. Generator restart signal. (Dry contact)

8. 3 times peak power. Strong loading capacity.

9. Overload, output short-circuit protection.


System parameter :


Over-load Protection: 110%<load<150%, beeps 0.5s every 1s, and fault after 60s off the output,

Load>150%, beeps 0.5s every 1s, and fault after 20s.
Surge rating(10s): 1:3(VA)
Power Saver: Load≦25W(enabled on “P/S auto” setting of Remote comtro;)
Protections: Low battery, over charging, overload, over temp
Indicatoers: LED+LCD Display



CNS110 Series Technical Specifications:


ModelCNS110 1KW-12KW
Line Mode Specification:LV Model(1-6KW)HV Model(1-12KW)
Input VoltageInput Voltage WaveformSinusoidal(utility or generator)
Nominal Input VoltageLV 12VacHV 230Vac
Low Line DisconnectNormal:85Vac±4%Normal: 184 Vac±4%
Wide: 80 Vac±4%Wide: 135 Vac±4%
Low Line ReconnectNormal:95Vac±4%Normal:194Vac±4%
Wide: 85 Vac±4%Wide: 145Vac±4%
High Line DisconnectNormal:136Vac±4%Normal:263Vac±4%
Wide: 140 Vac±4%Wide: 263Vac±4%
High Line ReconnectNormal:131Vac±4%Normal:253Vac±4%
Wide: 135 Vac±4%Wide: 253 Vac±4%
Max AC Input Voltage150V rms270V rms
Input Frequency

Nominal Input

Frequency

50Hz/60Hz(Auto detection)

Low Line

Frequency Re-connect

51+0.3Hz for 60Hz;

41+0.3Hz for 50Hz;

Low Line

Frequency Disconnect

50+0.3Hz for 60Hz;

40+0.3Hz for 50Hz;

High Line

Frequency Reconnect

64+0.3Hz for 60Hz;

54+0.3Hz for 50Hz;

High Line

Frequency Disconnect

65+0.3Hz for 60Hz;

55+0.3Hz for 50Hz;

Main FunctionOutput Voltage WaveformAs same as input waveform
Over-load Protection(SMPS load)Air switch

Output Short

Circuit Protection

Air switch

Max Bypass

Overload Current

40A/50A

Battery Inverter Mode Specifications:
Output

Output Voltage

Waveform

Sine wave

Rated Output

Power(KW)

LV:1-6KWHV:1KW-12KW
Power Factor0.9~1.0

Nominal Output

Voltage(V)

LV:120Vac±10% rmsHV:230 Vac±10% rms

Nominal Output

Frequency(Hz)

60Hz±0.3Hz

50Hz±0.3Hz

DC Voltage

Nominal DC

Input Voltage

12VDC/24VDC/48VDC
DC Voltage Range10-15.5Vdc for 12V battery
20-31.0 Vdc for 24V battery
40-62.0 Vdc for 48V battery
Low Battery Alarm10.5Vdc±0.3Vdc for 12V Battery
21.0 Vdc±0.6Vdc for24V Battery
42.0 Vdc±1.2Vdc for 48V Battery

Low DC

input shut-down

10.0Vdc±0.3Vdc for 12V Battery
20.0Vdc±0.6Vdc for 24V Battery
40.0Vdc±1.2Vdc for 48V Battery
High DC input alarm&fault16Vdc±0.3Vdc for 12V Battery
32Vdc±0.6Vdc for 24V Battery
64Vdc±1.2Vdc for 48V Battery
High DC input recorvery15.5Vdc±0.3Vdc for 12V Battery
31.0Vdc±0.6Vdc for 24V Battery
62.0Vdc±1.2Vdc for 48V Battery
AC ChargerNominal Charge Current20A/35A/50A/70A/90A(5satges adjustable charging current)
Charge Current Regulation±5Adc
Over Charge protectionBat.V≧15.5VDC for 12V battery
Bat.V≧31.0VDC for 24V battery
Bat.V≧62.0VDC for48V battery
Beeps 0.5s every 1s& fault after 60S
Algorithm
Three stage:Boost CC(Constant current stage) →Boost CV(Constant voltage stage) →Float(constant voltage stage)
Solar ChargerRated Charge Current40A60A
Rated Charge Battery Voltage Type12V/24V/48V12V/24V
Max PV open Circuit array voltage12V for 40Vdc
24V for 40Vdc
48V for 110Vdc
Charger ModeMPPT
PV Low Voltage Re-connectPV≧Bat.V=3V
PV Low Voltage DisconnectPV≦Bat.V
EfficiencyEfficiency≧97%
Efficiency(Battery Mode)≧85%
Efficiency(Line Mode)>98%
Transfer TimeAC to DC20ms(Max)
DC to AC15ms(Max)
General SpecificationsOperation Temperature Range0℃ to 40℃
Strorage Temperature-15℃~60℃
Operation Humidity5% to 95%(non-condensing)
Audible Noise60dB max
CoolingForced air, Variable speed fan
Dimension(L*W*H)

1-3KW: 526*423*260mm

4-6KW:530*396*190mm

7-12KW:627*416*204mm

Net Weight(Kg)1KW:21.5Kg;1.5KW:23.5Kg
3KW:30.5Kg4KW:32Kg
5KW:36.5Kg6KW:40.5Kg
7KW:43.5Kg8KW:50Kg
10KW:57.5Kg12KW:60Kg

China Hybrid Off Grid Solar Power Inverter 24V / 48V 1 - 12kw 50 / 60Hz Customized supplier