Application field:

  • Petrochemical industry
  • natural gas industry
  • power plant
  • power station

Description:

The CND310 series Electricity Special UPS system consisting of system cabinet, DBW bypass stabilized cabinet, and PDU feeder cabinet;


CONSNANT designs exclusively for power plant, transformer substation, and distribution substation according to the development requirement of China Power.


It possesses on-line double conversion and zero transfer function.


It can be mainly applied for power system telemechanics, PTU, power line carrier, power system monitoring and so on.


After being isolated and filtered by regulator, Single-phase 220V or three-phase 380V can provide stable power for load through inverter when the AC is normal.


If the failure of AC power grid supply or a power cut occurs, the backup of DC power system can invert to supply electricity through the reverse diode.


If the DC Power System is under voltage or cut off, the static switch will turn to bypass automatically. When the AC power is recover, the static switch will turn to AC power automatically.


If the inverter is overloaded or fault, the system will turn to bypass and indicates a warning signal at the same time.


Features:


Adopt full digital control technology


Intelligent detection and monitoring function


Digitally control the static switching with zero switch


Full isolation between input and output


Super low output zero earth voltage


DC UPS isolated with utility power Compatible with the DC power system and isolated with utility power completely


Cubicle design with the power standard both indication and cabinet (Can be customized according to customer demands)


Multifunctional protection for over voltage, under voltage, over current, short circuit and over temperature and so on.


Large-screen LCD monitor with Chinese and English operation interface


Ultralong 256 event record, user-friendly analysis and management to the situation of the power supply (touch screen optional)


Static bypass has a strong anti-overload capability


Model Number10KVA15KVA20KVA30KVA40KVA
Rating capacity8 KW12 KW16 KW24 KW32 KW
Rating voltage220VAC Single Phase (6-20KVA) / 380VAC Three Phases
AC input
Voltage range±25%
Frequency range50/60Hz±10%
Soft start0 – 100% 5 seconds
Power Factor0.95(with input filter)
Bypass input
Permitted voltage
range
±15%
Frequency range50/60Hz±5%
Output
Voltage accuracy220V±1%(steady load) 220V±3%( fluctuating load)
Permitted Frequency
range
50/60Hz±0.05Hz(powered by battery)
Power factor0.8
Waveform DistoritionLinearload<2%, non linear load<4%
Dynamic load
voltage transients
<5%
Crest factor(lpeak/
lrms)
3:01
Overload capacityNormal in 110% load, 125% for 10min
EfficiencyDouble conversion mode: 94%; ECO mode: 98%
DC
Battery voltage220V; (10-40KVA 110V is optional)
Cutoff voltage185V
Maximum discharge
current
36A55A73A109A145A
Panel display
LCDChinese/English UPS status, operation instruction input voltage, output voltage, current, frequency, battery voltage, value of charge and discharge
current, fault display , warning
Environment
Temperature0ºC-40 ºC
Humidity0-95%(no condensing)
Storage temperature-25 ºC—55 ºC
Altitude<1500m
Physical features
Weight(KG)Net230258350400480
Gross250285380425500
Dimesion
W X D X H mm
800×600×2260800×800×2260
OptionalRS485/SNMP/ Harmonic compensation cabinet/Input and output isolation cabinet/Lightning protection device/Bypass stablelized cabinet/
Customized appearance and size

Model Number50KVA60KVA80KVA100KVA
Rating capacity40 KW48 KW64 KW80 KW
Rating voltage220VAC Single Phase (6-20KVA) / 380VAC Three Phases
AC input
Voltage range±25%
Frequency range50/60Hz±10%
Soft start0 – 100% 5 seconds
Power Factor0.95(with input filter)
Bypass input
Permitted voltage
range
±15%
Frequency range50/60Hz±5%
Output
Voltage accuracy220V±1%(steady load) 220V±3%( fluctuating load)
Permitted Frequency
range
50/60Hz±0.05Hz(powered by battery)
Power factor0.8
Waveform DistoritionLinearload<2%, non linear load<4%
Dynamic load
voltage transients
<5%
Crest factor(lpeak/
lrms)
3:01
Overload capacityNormal in 110% load, 125% for 10min
EfficiencyDouble conversion mode: 94%; ECO mode: 98%
DC
Battery voltage220V; (10-40KVA 110V is optional)
Cutoff voltage185V
Maximum discharge
current
181A218A291A364A
Panel display
LCDChinese/English UPS status, operation instruction input voltage, output voltage, current, frequency, battery voltage, value of charge and discharge
current, fault display , warning
Environment
Temperature0ºC-40 ºC
Humidity0-95%(no condensing)
Storage temperature-25 ºC—55 ºC
Altitude<1500m
Physical features
Weight(KG)Net580650900950
Gross600675925988
Dimesion
W X D X H mm
800×800×2260800×1200×2260
OptionalRS485/SNMP/ Harmonic compensation cabinet/Input and output isolation cabinet/Lightning protection device/Bypass stablelized cabinet/
Customized appearance and size
China Electricity Online UPS |CND310 10 – 100KVA 380/400/415VAC 220VDC  anti-overload  digital control  user-friendly supplier

Electricity Online UPS |CND310 10 – 100KVA 380/400/415VAC 220VDC anti-overload digital control user-friendly

Inquiry Cart 0