Lithium Ion Batteries Battery Test Chamber Explosion Proof

Brand Name:SANWOOD
Certification:CE AND ISO
Model Number:SM-125-CA-FB-4
Minimum Order Quantity:1
Delivery Time:4-6 weeks or negotiable
Payment Terms:L/C, D/A, D/P, T/T, Western Union
Contact Now

Add to Cart

Verified Supplier
Supplier`s last login times: within 1 hours
Product Details Company Profile
Product Details

Thermal Aging Test Chamber for Lithium ion batteries Explosion Proof Chamber


Product Description

Sanwood thermal aging test chamber 4-in-1 design is a customised design for battery manufacturer, which is simulating the different temperatures conditions in each room. So there are 4 controllers in this design. Each room can be set a temperature different from others. The refrigeration system can be one-stage refrigeration system or two stage system, depends on the temperature control range.


Battery explosion proof thermal aging test chamber is mainly used for battery overcharge and discharge, charge and discharge test, the battery placed in the explosion-proof chamber at different temperatures, connect with charge and discharge tester externally, to determine the batteries performance and reliability at different temperature environment.


Thermal aging test chamber 4-in-1 main parameters


ModelSM-125-CA-FB-4
Temp. range

0°C ~80°C

Temperature stabilityHigh±0.5°C ,low ±1.0°C
Temperature uniformity≤±2.0°C
Heating Rate3.0 ~ 5.0℃/min
Cooling Rate1.0 ~ 2.0℃/min
Interior materialStainless Steel Plate ( SUS 304)
Exterior materialA3 plate with power coating. Color can be customized
Inner size (WxHxD) mm500x500x500 for each room
Working volume (L)500 L
Power supply380V AC, 50Hz/60Hz 3 phase
Sample holder2 pcs for each room, total 8 pcs
Fittingscable port(portΦ100mm) x4 (Size and quantity can be customized)
Refrigeration systemAir Cooled (Water Cooled is option)
Hermetic compressor
One stage refrigeration system
R408 AND R23 (Option: R449A, R508)
Explosion proof devices: Can be customized per customer's requirement, HL0~6 per EUCAR or USCAR

Note: 1. We reserve the right to change specifications without prior notice

2. Customized sizes and configurations available

3. Controller SH-5600,The control panel is provided with USB or RS232 port, a battery surface temperature detection display light( will be divided into three level alarm), a battery fault alarm reminder, a harmful gas alarm, an exhaust indication light, an emergency stop switch, outfire indication light and over temperature protection


Test standard comply and met:

GB 31241-2014,

GB/T 18287 -2013,

GB/T 8897.6-2008,

YD/T 2366.1-2011,

GB/T 21966-2008,

MT/T 1051-2007