Add to Cart
High Precision Load Cell Meter 0~200mv Input For Package Machine ST-10PD Tension Load Cell Meter
Intelligent Tension Meter For Tension Load Cell and Auto Tension Controller
Attention:STM-050 tension meter only display tension,no control signal output,other functions same as STM-10PD.
Parameters | |
Model | ST-10PD |
Power Supply | DC 24V |
Input Analog singal | 1. L+~L-;R+~R-;Left,right tension loadcell signal input |
STS tension loadcell signal (0~200mv,power supply DC5V) | |
STSA tension loadcell signal(0~15mv;power supply DC5v) | |
Control output | 1. Vout-GND:DC0~10V/0~5V |
2. Iout-GND:DC0~20mA/4~20mA | |
(STM-050 without Vout,Iout output) | |
Tension Display | L+R Total tension L: left tension R:right tension |
Fixed output | 5V+-GND:DC5V tension loadcell power supply |
Outline size | 96*48*109mm |
Features:
1. 32 Bit CPU guarantees high speed,precision,anti-jamming
capability and ensures reliability.
2. The outside has no adjustable potentiometer.
3. 0~10V /0~5V and 0~20ma/4~20ma output signals can be free to
choose.
4. Use dispensing technology, small volum,light weight.
5. Mosaic installation,simple and convenient.
Packing and delivery:
1. All pack with standard Carton box,Neutral with any Logo
2. Each piece in one separate box with manual instruction
3. All model with stock and can be sent out at once
4. All products with warranty 2 years
Using steps
1. Enter C11 ,according to the tension sensor type to set C11
parameter value:if it is differential sensor,the value is set to
0,if it is strain gauge sensor,the value is set to 0.
2. When use the tension meter output to participate the control
with PLC ,according to the actural need to set C09/C10.
3. Set the alarm value when it is needed,otherwise it has no alarm
with 0.0kg.
4. According to the actual need to set C04 full degree of
tension,its value should be 20%~80% of tension sensor rated range.
Notes for use
1. Set screw should not be too long when the bearing hourses are
installed on the detector.
2. Use spherical universal bearing hourses.
3. The wrap angle of film over detector reel should not be larger
than 120 around 60 would be perfect.
4. The load force caused by film tension should not point to he
screw ends of tension detector.
5. The screw ends of tension detector should point upwards when
installed on a wall.
6. If the force caused by film tension pulls but not pushes the
tension detector,so the negative and positive detector signal wires
should exchange when connected to the tension meter.