STM-050PD Tension meter Load Cell Meter Small Size With Dancing Roller / Load Cells For Tension Display
Digital Tension Controller Tension Meter With Dancing Roller Or Load Cells
Features:
Key intelligently set zero, scaling, operation simple convenient.
1. Can select left /right total tension display.
2. Adapt SMT ,small size,light weight.
3. Tension controller with STS ans STSA for option.
4. Hardware and software to restrain power frequency interference, output steady and reliable.
5. Bedded installation,easy and convenient .
Attention:STM-050 tension meter only display tension,no control signal output,other functions same as STM-10PD.
Parameters | |
Model | ST-10PD/STM-050 |
Power Supply | DC 24V |
Input Analog singal | 1. L+~L-;R+~R-;Left,right tension loadcell signal input |
STS tension loadcell signal (0~200mv,power supply DC5V) | |
STSA tension loadcell signal(0~15mv;power supply DC5v) | |
Control output | 1. Vout-GND:DC0~10V/0~5V |
2. Iout-GND:DC0~20mA/4~20mA | |
(STM-050 without Vout,Iout output) | |
Tension Display | L+R Total tension L: left tension R:right tension |
Fixed output | 5V+-GND:DC5V tension loadcell power supply |
Outline size | 96*48*109mm |
Work with loadcell as below:
Parameters | |||
Power supply | DC5V~12V | Comprehensive | ≤±0.5% F.S |
Output Signal | 0~20MV | Temperature Range | ‘-20℃~+70℃ |
Input Resistance | 380±2Ω | Temperature coefficient | ≤±0.03% F.S/10℃ |
Output Resistance | 350±2Ω | Zero Output | ≤±1% F.S |
Rated stroke | 3kg~600kg | Safety Overload | 150% F.S |
Electric connection | Power + red,power - green Signal + yellow Signal - White |
Electrical Wiring
L+:positive terminal of tension detector input signal on left side
L-:negative terminal of tension detector input signal on left side
5V+:positive terminal of tension detector power supply on both sides
PE:detector shielding cable on both sides
GND:power supply negative terminal on both sides
R+: positive terminal of tension detector input signal on right side
R-:negative terminal of tension detector input signal on right side
STS sensor wiring
Iout: 0~20mA output
Vout: 0~10V output
5V+: 5V output
GND: output negative terminal of voltage and current
Zero calibration
Machine power off, there is no film or film is loose.
Enter C01 parameter screen,press button can change C01 from 0 to 1,when it change from 1 to 0 automatic,zero calibration is completed.
After zero calibration,if up LED displays error and alarm indicator lightens,refer to section7, 8 for the problem.After trouble is remove,return C01 to zero calibration.
Span calibration
Machine power off.Thread a string through the reeler center like what the material does during the actual operation.Hang weights on the end of the string while the other end is fixed well.
The weights should be more than half of the rated measurement range of the detetor.
Enter C02 ,use , button to change its value to be equal to the hanged weight in Newton.
Enter C03,press button,change its value from 0 to 1,when 1 change to 0 automatic,span calibration is completed
After span calibration,if up LED displays error and alarm indicator lightens,refer to section7, 8 for the problem.After trouble is remove,return C03 to span calibration.
Packing and delivery:
1. Neutral carton packing
2. One piece in one carton box
3. Normally one controller with two loadcells,this is easy for
shipping.
4. One unit shipping
5. Lead time:within 3 days