Add to Cart
Analog Signal Tension Amplifier DC24V With Two Load Sensors High Precision Tension Transducer
Measuring Amplifiers Tension Amplifier DC24V Connecting Two Load Sensors In Printing Machine
Measuring amplifiers ensure a stable bridge supply voltage, They amplify the output signal of the load sensors to a standard signal .
STA-05 Intelligent tension transducer
Features:
1. Key intelligent operation,outside without adjust potentiometer.
2. Hardware and software to restrain power frequency interference, output steady and reliable.
3. Adapt DIN-rail mounting,easy and convenient.
4. Adapt SMT,small size,light weight.
5. Tension controller with STS ans STSA for option.
Parameters | ||
Model | STA-05C | STA-05B |
Power Supply | DC 24V | |
Input Analog singal | L+~L-;R+~R-;Left,right STS tension loadcell signal (0~200mv,power supply DC5V) | L+~L-;R+~R-;Left,right STSA tension loadcell signal (0~15mv;power supply DC5v) |
Control output | 1. Vout-GND:DC0~10V/0~5V 2. Iout-GND:DC0~20mA | |
Fixed output | 5V+-GND:DC5V tension loadcell power supply | |
Outline size | 115x100x23 |
Features:
32 bit CPU guarantees high speed, precision, ant-ijamming capability and ensures reliability.
The outside has no adjustable potentiometer.
The tension sensor can select Differential sensor or Strain- gauge sensor.
0~ 10V/ 0~ 5V and 0~ 20mA output signals can be p-rovided to PLC and display instrument.
Use dispensing technology, small volume, light wei-ght.
Using DIN rail mounting, simple and convenient.
Product category:
STA - 05B : Using strain - gauge sensor , input signal r - ange - 5mv ~ + 10mv.
STA - 05C : Using differential sensor , input signal ran - ge - 100mv~ + 200mv
Notes of Using Tension Detector
1. Set screws A and B should not be too long when the bearing houses are installed on the detector. Other-wisethe force could not cause relevant deformations and displacements on the detector. Use spherical u-niversal bearing houses to avoid the detectors on b-oth sides interacting on each other, causing errors on calibration.
2. The wrap angle of film over detector reel shouldn’t be larger than 120, around 60°would be perfect. The s-ignal detected by detector would be too weak to con-trol tension effectively with a large wrap angle.
3. The load force caused by film tension should not poi-nt to the screw ends of tension detector. Otherwise t-here will be very low or even no output.
4. The screw ends of tension detector should point upw-ards when installed on a wall.
5. If the film is pulled cross the reel from below, the fo-rce caused by film tension pulls but not pushes the tension detector. So the negative and positive detec-tor signal wires should exchange when connected to the controller terminals.
veral ways as follows:
[ 1] Tension sensor connection drops or poor contact. LED1 twinkle shows left tension sensor has problem, LED3 twinkle shows right tensioin sensor has problem, ple-ase check sensor connection.
[2] The difference of signal between left sensor and right sensor is too large. When the LED twinkle , it shows the sensorsignal is too small,please ajust the sensor or change it.