Single Flame Source Ignitability Test , Flammability Test Apparatus EN ISO 11925-2

Brand Name:YUYANG
Certification:GB/T 8626, EN ISO 11925-2, DIN 4102
Model Number:YY510
Minimum Order Quantity:1 set
Delivery Time:10 work days
Payment Terms:T/T, L/C, Western Union
Contact Now

Add to Cart

Verified Supplier
Location: Dongguan Guangdong China
Address: B1505, FORTUNE PLAZA, No.1, Yuanmei Road, Nancheng District, Dongguan City, Guangdong Province, China
Supplier`s last login times: within 25 hours
Product Details Company Profile
Product Details

Building Material Ignitability Test Apparatus EN ISO 11925-2 Single-Flame Source


Description:


Ignitability test, also called single-flame source test .Test apparatus corresponds to standard EN ISO 11925-2. Test results of the building structure can be classified according to standard 13501-1.

The dimensions of the test specimens shall be (250 ) mm long by (90 ) mm wide.

45°-tilted burner is advanced horizontally until the flame (length 20 mm) reaches the pre-set contact point with the test specimen. Tests may need to be conducted to either surface exposure or edge exposure, or both. The flame application time is 15 or 30 seconds as required by sponsor.

During the test following is recorded: whether ignition occurs; whether the flame tip reaches 150 mm above the flame application point, and the time at which this occurs; whether ignition of the filter paper occurs; observations of physical behavior of the test specimen.


Standards:


GB / T8626-2007 Test Method of Flammability for Building Materials

EN ISO 11925-2:2002-Reaction to fire tests- Ignitability of building products subjected to direct impingement of flame-Part 2: Single-flame source test

DIN 4102


Specifications:


This apparatus made up of two parts: burning chamber and control device.

Power supply: AC220V±10%,50Hz;

Burner: diameter 0.17mm burner with regulator; four ¢4mm air suction inlet;

Gas source:>95% propane gas;(user should provide for themselves)

Gas pressure:10kpa~50kpa

Flue air velocity:0.7m/s only on condition of burner burning and draught hood open,

Time adjustment of continuous flame: 0 ~ 99minutes99seconds

Time adjustment of afterflame: 0 ~ 99minutes99seconds

Timer accuracy:≤1s/h

Anemometer accuracy:±0.1m/s.

Burner angle: 45°

Material: stainless steel

Observing window: two big viewing windows on the front and right side


Whole set: control device, burning chamber,burner,magnetic valve,flame lighter, signal control line and specimen holder.

Equipped with a digital anemometer/thermometer and a stopwatch for simple but accurate measurement of the flow, temperature and time.



BS EN ISO 11925 Part2-2010.pdf

China Single Flame Source Ignitability Test , Flammability Test Apparatus EN ISO 11925-2 supplier

Single Flame Source Ignitability Test , Flammability Test Apparatus EN ISO 11925-2

Inquiry Cart 0