Cable Horizontal and Vertical Burning Test Apparatus, UL1581 Horizontal Flammability Tester
Description:
Cable horizontal and vertical burning test apparatus(VW-1)is
designed according to UL1581 sect 1080.1~1080.14, and meet the
criteria of VW-1(Vertical-specimen)Flame Test. It can be used to
test of 1060 products wire and cable FT1 and vertical burning
test,1080 VW-1 test, 1061 test, 1090 horizontal test and 1100
horizontal specimen or FT2 test;to assess the flame spreading
ability to combustible near by of cable or flexible wire when it
caught fire.The whole test is carried out in a sealed test chamber
with a volume of 4.32 M3.
Test method: adjust the flame height to placed the specimen at the
top of the flame, burning for 15 seconds, extinguished 15 seconds,
repeat 5 times,then inspecting the burned situation of the
specimen, it can be set the combustion, extinguish and repetition
asthmatically.
User's Experience:
1, The cabinet is assist with upper and lower two sections, it
would be easy to move into test room;
2, Touch-screen control system, convenient for operation;
3, 6 test program for select;
4, Burner angle moved automatic.
• UL1581 sect 1060~1100
• ASTM D 5025
• ASTM D 5207
Structure Features:
1, The test chamber is electrolytic plate electrostatic spraying,
elegant appearance, and inside is roasted black.
2, The tester is equipped with powerful exhaust fume extractor,
when the test is complete, open and air supply system and exhaust
to the outdoors, and during the test, the system is closed;
3, The air throttle is equipped behind the test chamber.After the
completion of the test, open the ventilation system to air
distribution in the cabinet,But during the testing, the air door
should be closed.
4, The glass viewing window is on the front box, allowing easy
observation during the test.
5,The test chamber is equipped with sealed glove to operate the
burner inside.
6, Test chamber size: available space 2.1M (l) *1M (w) *2.1M (h),
capacity: 4.48m3. Dimensions 2.4m (l) *1M (w) *2.3M (h).
Temperature measurement system:
1, A thermal sensor (copper tubing and thermocouples)-tube
structure should be very high conductivity electrolytic copper.
Length of 19.14 ± 0.02mm.
2, K-thermocouple, 0.5mm diameter of stainless steel tubes as a
sleeve.
3, The digital temperature meter with match with imports K-type
thermocouple, which readings greater than 1000 degrees centigrade.
4, Equipped with electronic stopwatch: accurate to 0.1s.
Apparatus and Fixture:
1, The main fixtures include test stand and burner fixture
2, The burner inner-diameter is 9.5 ± 0.5mm, fire mouth diameter is
0.90 ± 0.03mm; burner pipe is 102mm. Air supply is adjustable;
3, The height of flame is adjustable; Standard requests are: total
height of flame is 125 ± 10MM, blue inner flame height is 40 ± 2mm
; flame test angle is adjustable from 0 to 45°.
4, Imported gas special flowmeter and precise needle valve
controlling gas flow.
5, Imported brands of pressure gauges and control valve working gas
pressure;
6, Test stand is made of stainless steel, and include horizontal
bracket, vertical support an independent type, also as FT1, FT2,
VW-1, three kinds of specifications. The plant of vertical support
and blowtorch is parallel to the observation window plane, easy for
viewing and operation.
7, The burner is imported from USA, it fit to ASTM D 5025-99
request
8, High voltage electronic ignition system, and automatic cut off
of gas supply for security control system
9, Wedge-shaped frame: Add wedges, the burner is installed in the
wedge, and can be easily moved and moved back to the defined
position very accurately.
Control System:
1, PLC with touch screen control system achieving testing process
automatic control.
2, The test time can be set freely by customers;
3, Combustion both vertical and horizontal burning test mode;
4, An experimental system automatically calculates and stores the
test data.
5, Burning settings: 0-999.99 seconds to set arbitrary
6, To stop burning set: 0-999.99 SEC to set arbitrary
7, Burning count: 0-999 set
Parts list:
1, 94 g/m2 kraft paper flag, the strip width is 1/2In or 10MM,
thick or near 5mil or0.1mm,
2, Equipped with a set of flame height ruler;
3, Equipped with a 500mm length ruler; and the accurate is 1mm.
4, The cotton layer thickness not greater than 1/4in or 6mm.
Electrical specifications:
1, The power supply: AC220V 50/60Hz, 1A
2, Manual certificates:supplied
3, Air source: methane gas (customer-owned)
4, Dimensions:2150mm x 1200mm x 2150mm