Add to Cart
UL 1730 ASTM E108 Solar Cell Spread of Flame & Burning Brand
Testing Equipment
Product introduction:
Solar Cell Spread of Flame & Burning Brand Test Machine is
based on UL 1730, IEC 61730-2 design and development. Is to
simulate real conditions to assess roof and components of
fire-resistant performance of the instrument, in A1.82m, b 2.4m and
c 3.9m specimens to evaluate A~C level. Also can be used in
fire-retardant performance of photovoltaic components used in this
test.
Standards:
UL 1730: multi-family and hotel room individual dwelling unit smoke
detection
monitors: electric signal detection of house dust;
UL 790: standard method of fire test for roof covering materials;
ASTM E108-04: standard method of fire test for roof covering
materials;
NFPA 256: fire test of roof deck.
IEC 61730-2 Appendix b: fire tests on PV modules.
Equipment characteristic:
Structural parts
1, Plywood roof covering materials, dimensions: 1,300 (w) X1,000
(d) x120 (h), to
install the test sample;
2, Non-combustibility test Board, installed at the end of testing,
can stop the test
panels tempered;
3, Stainless steel fan control board, the test angle can be
adjusted,
size: 1,440 (l) x 940 (h) mm;
4, Used to support the testing of the main frame bracket,
corrosion-resistant steel, dimensions: 1,020 (l) x 1,000 (d) x
1,473 (h) mm;
5, Non-combustible plate Assembly, installed in front of the frame
to simulate the
eaves and cornice, extension of the flame from the burner to the
specimen,
dimensions: 330 (w) x 2,130 (d) x 584 (h) mm;
6, Air flow rate for the test panel: 19 ± 8 km/h (5.5M/sec), and
configure the
anemometer monitor;
7, Separate ventilation pipes, can be extracted from outside the
laboratory air;
8, Honeycomb filter is installed in the air duct, installed gas
inlet guide vane;
9, Ventilation ducts equipped with slope adjustment panel for
adjusting the air flow direction;
10, Ventilation pipes attached to the Guide, can enhance speed to
ensure supply test airflow from the outside interference, guide
plates made of stainless steel, location does not change with the
wind pressure;
11, Duct materials for stainless steel, corrosion-resistant and
heat-resistant, size: 2,130 (w) x 762 (h) x 3,000 (l) mm;
12, Fan 220V,50HZ, three-phase power, is equipped with a reverse
system can automatically adjust wind speed, minimum flow for
300m3/min;
13, Infinitely variable speed inverter, 0-100% adjustable;
14, Gas burners (for intermittent Shi Huo, flame spread and flying
fire), 1.12m, 60.3mm, moving in the test side has a 12.7mm (w)
*0.91m (long) slit;
15, Gas burner can provide a 22,000Btu/min (387kWh), and according
to a, b, c three combustion levels, high-precision gas control
valve controlling gas flow,
16, Top burner thermocouple is installed 58.7mm, 888 ± can test 28
ºC;
17, Automatic ignition system, ensure the security of test
performance, ignition electrode 1.8kVp mass flow controller is the
minimum pressure according to different standards, control gas flow
rates, Class A and B:21,000 ~ 22,000 Btu/min (369 ~ 387 kWh) for 10
minutes, Class C:18,000 ~ 19,000 Btu/min (316 ~ 334 kWh) 4 minutes;
18, Temperature control system-Class A and B:760±28ºC
(1400±50ºF)-21,000 ~ 22,000 Btu/min-Class C:704±28 c
(1300±50ºF)-18,000 ~ 19,000 Btu/min
19, High precision pressure gauges and pressure regulating valve
controls the gas pressure;
1)-Each transfer to gas in the burners need to follow a different
test and control methods;
2)-LNG: using MFM can accurately measure flow (flow control valve
control);
3)-LPG: air flow rate using the inverter system: the test deck at
19 ± 8 km/h (5.5M/sec);
20, Metallic mesh support materials, pallets can be rotated, so
that full combustion of
materials;
Test section
1, Computer control system of United States special control
software for Labview experiment, integration 10.2 "LCD scree;
2, Data acquisition systems, LabView programming language is used
to program, data acquisition cards United States NI offers
3, Data acquisition system consists of the following parts:
1) 16-bit thermocouple input module
2) 16 bit a/d conversion input module
3) Data input/output module
4) 12 bit a/d conversion output module
5) 4 and 8-slot backplane
6) Labview modules
7) Labview/Ethernet network module
4, Brand testing systems, gas burners, the flame engulfed the
burning material, the gas burner is 880±10ºC temperature can be
adjusted;
The standard results
1, General standards for flame spread
1) Any part of the roof covering materials (component or Panel)
from the test deck in flame or glowing particles blown,
2) Can slide through, split, curved roof covering materials, such
as roof deck open,
3) Fire safety rating A: flame spread range is 1.82M,
Fire safety level B: flame spread range is 2.4M,
Rank C fire safety: fire spreading area is 3.9M,
Measured from the edge of the sample spread of flame,
2, General standards for roof combustion,
1) Any part or component of the Panel from the test deck in flames
blowing or falling,
2) Parts of the roof deck or a part of a Panel in the roof
structure or component in the form of luminous particles disappear,
3) Continue with components or panels of combustion,
Equipment specification:
Model | YY137 |
Dimensions | About 6,000 (w) X2,200 (d) X2,000 (h) mm |
Power supply | AC 380V 3-Phase, 50/60Hz, 50A |
Weight | Approx. 850kg |
Brochure | Can provide |
Exhaust | Minimum 400 m2/min |
Tools | Propane gas/liquefied natural gas, Compressed air, Vacuum cleaners, Computer |