Add to Cart
Stainless Steel Small Balls And Suction Cups Test Template E 16CFR 1510 ASTM F963
Description:
It conforms to the standard requirements of the 16CFR 1510/ASTM F963,and EN-71. It is used to test whether the small ball of the toys can be swallowed by the children leading to the suffocation.
Parameters:
Item | Template E |
Material | Stainless steel |
Test | Small balls and suction cups test |
Figure | 36 |
Standard | EN71-1 Clause 8.32, 16CFR 1510/ASTM F963 |
Package | Wooden case |
EN71-1
8.32 Small balls and suction cups test
8.32.1 Small balls and suction cups
Position and clamp template E shown in Figure 36 so that the axis
of the slot is substantially vertical and the slot is unobstructed
at its top and bottom openings.
Place the ball or the suction cup or the toy with an attached
suction cup without compressing it, in any orientation in the slot
so that the force on the ball or suction cup or toy with an
attached suction cup is only the force due to its mass.
Determine whether the ball or suction cup or toy with an attached
suction cup passes entirely through template E.
8.32.2 Small balls attached to a toy by a cord
Position and clamp template E shown in Figure 36 so that the axis
of the slot is substantially vertical and the slot is unobstructed
at its top and bottom openings.
Suspend the ball by the toy and its cord and lower the ball,
without compressing it, into the slot so that the force on the ball
is only its force due to its mass. Before the distance A is
measured, the ball shall be lowered as far as the cord and the
attached toy allow.
Determine whether the ball passes through the base of template E
such that the distance A indicated in Figure 37 is greater than 30
mm. The distance A shall be measured from the top of the template
to the intersection point of the major and minor axes of the ball.