Add to Cart
Ventilation Type Aging Test Chamber for Testing the Wire And Cable Insulator ±2.0ºC
Product Description:
Ventilator-Aging Test Chamber is used to test the material
heat-resistance of polymer materials (plastics, plastic) and
electronic parts, electrical insulation materials, such as: Wire
and cable sheathing, heat-shrinkable tubing, rubber or PVC
materials.
Ventilation Conversion Formula:
N=3590(X-Y)x2/VDt
N: Ventilators;
V: Capacity of case;
X: Power consumed when open the air valve
Y: Power consumed when closed
T: Temperature difference between working and environmental
features:
1. Easy to operation and the box using CNC machining, elegant
design, innovative and adopt counterproductive handle.
2. Internal material is high imported SUS304 mirror Stainless steel
or 304B TIG, outside is A3 Steel spray, it improves the texture and
appearance of cleanliness.
4. You can visually observe through huge Tempered glass windows
with lights anytime and clearly.
5. Good uniformity of temperature
7. With D.50mm test holes on the left side for external test power
line or signal line.
Saftey device:
1. With no-fuse protection switch
2. Control system with phase sequence protection and low voltage
electrical protection.
3. With over-heat protection switch.
4. Over load protection device for refrigeration compressor.
5. Refrigeration compressor high and low voltage protection switch.
6. Refrigeration compressor over oil pressure protection.
7. Lack of Anti-phase protection system.
8. Overload protection for circulation fan motor.
Model | YYW-013-45 | YYW-013-60 | YYW-013-75 |
Internal Dimension W×H×D(mm) | 450×500×450 | 500×600×500 | 600×750×600 |
External Dimension W×H×D(mm) | 1000×1000×700 | 1150×1200×850 | 1350×1500×1000 |
Internal and External Material | Material of the inner box is SUS 304# stainless steel, of the outer box is stainless steel or see cold-rolled steel with paint coated. | ||
Temperature Range | RT+10 degree ~200 degree (300 degree ) | ||
Uniformity of Distribution | ±2.0 degree | ||
Air Ventilation Rate | 0-200 times/hr adjustable, with an ventilative adjustment button, Watt/Hour | ||
Speed of Test Frame ( RPM) | 5-10 | ||
Power | AC220V |
Standard:
UL1581-2006:420.9, ASTMD5423-2005, ASTMD5374-2005