Add to Cart
Introduction
The International Electrotechnical Commission IEC 60754 Part 1 and
Part 2 test is performed to determine the degree of acidity of
gases evolved during the combustion of materials taken from
electric cables by measuring the pH & conductivity.
IEC 60754-1 is halogen-free cable came from and including the
polymer to halogenated compounds on the basis of the additive
compounds emitted during combustion, except the fluoridation
hydracids, it is measurement for gas of halogen volume, IEC 60754-2
for electrical or optical cable from compounds emitted during the
combustion of measure the gas of oxidation limit.
Standards:
IEC 60754-1: Test on gases evolved during combustion of materials from cables - Part 1: Determination of the amount of halogen acid gas
IEC 60754-2: Test on gases evolved during combustion of electric cables - Part 2: Determination of degree of acidity of gases evolved during the combustion of materials taken from electric cables by measuring pH and conductivity.
Features
1200°C Split-Hinge Tube Furnaces for horizontal use.
Heating element modules for superior radial and linear temperature uniformity and fast heat up and cool down.
Long-life, energy-efficient elements require little or no maintenance.
Mode conversion switch (Test method of IEC 60754-1&2 could be selected).
Alarm Temperature Controller: Temp controller to protect overheating of furnace.
Quartz work tube and sample lading assembly.
pH and conductivity measuring instruments with digital display and electrodes Stirrer.
Mass flow meter control the flow rate of air and digital display.
Activated Charcoal (air filtering): Filter for filtering the supplied air (activated charcoal).
Silica Gel (air drying): Device for drying the supplied air.
100 ceramic sample boats
Installation requirements of IEC 60754-1&2 Halogen Acid Gas Release Corrosion Tester
Electrical | 110V AC 60Hz / 230V AC 50Hz, 15A |
Ambient Temperature | Operating 10°C to 35°C |