Add to Cart
Products:
Large furniture calorimeter is based on GB / T 20286-2006
requirements in Appendix B and C of R & D production; the
device can measure exposure to an open flame ignition source under
the upholstered furniture and furniture components and combustion
performance tests. The device meet GA111-1995, "Standard Test
Method for Surface entity room fire products" GB / T 27904-2011 and
GB / T 25207-2010 part of the requirements of the test (Note: The
entity room part is optional);
The equipment consists of an ignition source, conical collector,
exhaust pipes, fans, weighing station and measuring device
component; test system comprising: a gas collection and analysis
system; gas control system; weighing measuring system; smoke
density test system;
Pipeline built-in temperature sensors, gas flow meters, gas
sampling probe and a multi-stage filter sampling line analytical
instruments to ensure long life.
Software control system under Windows can automatically collect and
perform complex data analysis and recording. Software can
automatically calculate the heat release rate, mass loss rate and
smoke density and other relevant parameters, and gives detailed
product test reports. Equipment while providing data printing
interface.
Standard:
GB / T 20286-2006 public places burning flame retardant products
and components performance requirements and labeling
Entity room fire test surface material GA111-1995
Combustion performance test method of furniture and components GB /
T 27904-2011 flame ignition
Technical Parameters:
1, Paramagnetic oxygen analyzer from 0 to 25%, accuracy not less
than ± 0.05%, response time of less than 3s.
2, CO2 analysis resolution ± 0.1%, range 0-10%
3, CO analysis resolution ± 0.02%. Range 0 to 1%
4, Imports of heat flow meter accuracy ± 2%, range 120KG / m, 0.5%
repeatability error.
5, Filter precision of three soot filter system 0.2um, to ensure
long-term life of gas analyzers;
6, The gas collection system uses a compressor-type condenser,
precise control of temperature of the gas collected at 4 ºC ± 1 ºC;
gas analysis more accurate;
7, Exhaust pipe exhaust rate is controlled by imported capacitive
pressure transmitter 0 ~ 2000pa; calculated by computer, accurate
control of exhaust rate;
8, Weighing systems using C3 level of imports weighing sensors;
linear weighing data acquisition and automatic record store;
9, The gas sampling system using samples diaphragm displacement 10L
/ min ~ 50L / min;
10, Smoke density measurement system using a color temperature of
2900 ± 100K and photometer white smoke density. Colorimetric
detector standard function accuracy no less than ± 5%.
Features:
Independent test and gas analysis equipment console:
1, Touch LCD and PLC intelligent control system and data printing
configuration interface.
2, Paramagnetic oxygen analyzer from 0 to 25%, accuracy not less
than ± 0.05%, response time of less than 3s.
3, CO2 analysis resolution ± 0.1%, range 0-10%
4, CO analysis resolution ± 0.02%. Range 0 to 1%
5, The color temperature (2900 ± 100) incandescent light source and
photometer smoke concentration - time curve
6, Compressor refrigeration condenser to remove moisture,
temperature control is accurate, and with a temperature alarm.
7, Pores with inert material intensive sampling probe to detect
oxygen concentration, and CO, CO2 concentration
8, Bidirectional probe and imported pressure transmitter accurately
measure gas flow rate
9, 2900 ± 100K color temperature of white light and smoke density
photometer. Colorimetric detector standard function accuracy no
less than ± 5%.
10, 0.2um multi-stage dust filtration systems and gas dryer and CO2
absorbents
11, The condenser control sample temperature 4 ºC ± 1 ºC
12, Stainless steel hoods 3m X 3m to ensure no smoke leaks
13, Exhaust capacity of not less than 3.5m³ / S exhaust fan to
speed, to ensure that the hoods can collect all the smoke; flue gas
flow meter accuracy no less than ± 5%, the response time of less
than 1s.
14, Windows environment computer control system; experiment
intelligent, easy and convenient; test data is automatically
stored, automatic calculation, free retrieval; printable;
Upholstered furniture combustion performance test equipment
features:
1, Square igniter size (250mm ± 10mm) x (250mm ± 10mm); stainless
steel tube thickness 0.89mm ± 0.05mm
2, Ignition position adjustable; vertical distance upholstered 51mm
± 3mm; horizontal distance upholstered 25mm ± 3mm;
3, Independent movable time display units.
4, Automatic ignition system; automatic timing;
5, Combustion systems, weighing station, the sample holder
integration design; test and measurement equipment more stable,
easy to damage;
6, Weighing the audience set, fire protection and drainage system
design.
7, The gas flow is automatically set; the gas emergency shut-off
devices.
8, Each time data acquisition and data processing no more than 5s;
9, Test data report includes: the oxygen concentration, carbon
monoxide, carbon dioxide concentration, temperature, smoke density,
heat release rate, mass loss rate, etc;
Components and furniture combustion performance test equipment
features:
1. Square sandbox igniter size 170mm x 170mm x 145mm; stainless
steel thickness 1mm; can
2. Weighing station using imported load cell, anti weighing
eccentric design and insulation designed to prevent scale drift
3. The gas valve and ignition automatic control, be sure to open
the gas valve and began firing.
4. The gas supply system consists of liquid propane bottle,
pressure reducer, regulators, measuring devices and gas pipeline
route composition;
5. The gas emergency shut-off devices.
6. C3 grade imports weighing sensor to accurately measure the mass
loss rate
7. Waterproof weighing system designed to prevent damage to the
heavy fire extinguishing system.
8. Sandbox burner propane gas and equipped with emergency shut-off
devices.
9. Combustion systems, weighing station, the sample holder
integration design; test and measurement equipment more stable,
easy to damage;
10. The test data report includes: the oxygen concentration, carbon
monoxide, carbon dioxide concentration, temperature, smoke density,
heat release rate, mass loss rate, etc;
measurement range: | 0-25% |
Signal output: | 4-20mA |
Response time T90: | ≤3S |
Environment temperature: | 0-45 ℃ |
Relative humidity: | <90% (no condensation) |
Linearity: | <±0.1% O2 |
Zero drift: | 0.05% O2 (one week) |
stainless steel tube thickness | 0.89mm ± 0.05mm |
Square igniter size | (250mm ± 10mm) x (250mm ± 10mm) |
The condenser control sample temperature | 4 ºC ± 1 ºC |