4mm Cassette Veterinary Test Kits , Rapid Diagnostic Test Kit Fit Hand Foot And Mouth Virus

Brand Name:New Life
Certification:ISO, CE
Minimum Order Quantity:1000pcs
Delivery Time:15 days
Payment Terms:T/T, Western Union
Place of Origin:China
Contact Now

Add to Cart

Verified Supplier
Location: Ningbo Zhejiang
Address: 12F,Guting Building,Hefeng Creative Square,No.495 Jiangdong North Road,Ningbo,Zhejiang, China
Supplier`s last login times: within 37 hours
Product Details Company Profile
Product Details

Bovine and goat Foot and mouth disease virus rapid test ,4mm cassette rapidly and easily, gold colloidal method


Intended Use


Bovine Tuberculosis Antibody Test is a sandwich lateral flow immunochromatographic assay for the qualitative detection of Tuberculosis Disease in bovine serum.


Test Principle


This rapid test is an immuno-chromatographic test, using colloidal gold immunoassay method, to detect the antibody against FMD virus in whole blood, serum. After adding sample, the sample move along with the colloidal gold labeling FMD antigen, is there is FMD antibody in the sample, it combines with antigen on T line and show wine-red color; if there is no FMD antibody, then no color reaction.


Components


1FMD Ab test card50 pieces
2Dropper50 pieces
3Antibody titers Colorimetric card1 piece
4Disposable gloves1 pair
5Manual1 piece

Test Procedure


1) Collect whole blood, separate serum (centrifuge at 2000-3000 r/min for 5~15min or separate out naturally at 4℃ overnight), or take whole blood with anticoagulants as sample. Take whole blood without anticoagulants as sample is also OK, but must test it immediately.

2) Open the package, take out test card, put it on clean, flat desk.

3) Use dropper to absorb the sample, adding 3 drops sample into “S” mark well slowly drop by drop.

4) Judge the result in 10-20min, it is invalid beyond 20min.


INTERPRETATION OF RESULTS


Positive: control line and test line are both seen wine red, the more the antibody exist, the thicker the color appear;


2) Weak positive: control line and test line are both seen wine red, but the color of test line is very light;


3) Negative: only control line is seen wine red;


4) Invalidation: control line isn’t seen wine red.


QUALITY CONTROL


A procedural control is included in the test. A line appearing in the control region

(C) is considered an internal procedural control. It confirms sufficient specimen volume, adequate membrane wicking and correct procedural technique.

Control standards are not supplied with this kit. However, it is recommended that positive and negative controls be tested as good laboratory practice to confirm the test procedure and to verify proper test performance.


Notice


1) Do not use test card out of date and bad package;

2) Do not use pure water, running water and normal saline as negative control;

3) Store at room temperature (< 30℃) is OK. If store in cool, need return to room temperature firstly, then open package, avoid moisture. Use the test card as soon as possible after open the package.

4) Do not touch the white membrane surface in the middle of test card.

5) To ensure the test quality, take fresh, unpolluted sample. If there is a lot of blood lipids, it will affect the result, so after centrifuge, take serum to test, avoid fat. If the blood or serum is sticky or not enough, use normal saline to dilute at same dilution factor to dilute, then to test.

6) If the serum can not be tested immediately, store at 4℃ for short time (in 48hours), store at below -20℃ for long-tern storage.

7) Whole blood without anticoagulants should be tested immediately; if already exist part of cruor, separate serum to test. The whole blood with anticoagulants should be tested in 24hours, do not frozen. Freezing and thawing causes hemolysis of red blood cells rupture, seriously affect the test results.

8) When dropping sample, keep head of dropper and “S” well at 1cm to ensure adding sample accurately. If too close, can cause small droplet volume caused by drips judgment error or is not allowed to join the sample size, influence the test results.

9) Avoid bubble when adding sample, the sample quantity should be controlled at about 100ul (about 3 drops). Too much sample would not increase sensitivity. In particular, the whole blood of excessive have made erythrocyte sedimentation in "show hole" place, causing membrane chromatography is so deep into the red background, seriously affect the results.

10) The antibody level is only related to darkness of T line, no relation with C line. Only the C line is clean to see, it means the test is valid.

11) Treat the test card and sample at pollutant according to local regulations.


ORIENT NEW LIFE MEDICAL CO., LTD.
Contact:Jerry Meng
Email:Jerry @ newlifebiotest .com
Tel.+86 18657312116
SKYPE

enetjerry



performance characteristics


The specimen correlation study was performed on 283 Blood specimens. 22 positive urine specimens and 218 negative urine specimens were confirmed by GC/MS.


Table 1: Specimen Correlation

GC/MS
Bovine Foot and Mouth Disease rapid test+-
+7815
-4203
China 4mm Cassette Veterinary Test Kits , Rapid Diagnostic Test Kit Fit Hand Foot And Mouth Virus supplier

4mm Cassette Veterinary Test Kits , Rapid Diagnostic Test Kit Fit Hand Foot And Mouth Virus

Inquiry Cart 0