45KW Grey Adjustable DC Load Bank for 600VDC Battery Testing
Why need load bank testing?
It is really critical to ensure that your standby power supply
system say UPS(uninterrupted power supply), battery bank,
generator, transformers, inverter etc which especially located in
harsh, dusty or corrosive environment working in good condition,
when you need them most, if switched to be loaded when the main
power supply in maintenance procedure or stop abnormally.
DC load bank testing offers you whole solutions of predictive
failure analysis for UPS(uninterrupted power supply), generator,
transformers, PV system, inverter etc, to validate the condition
and output of such power systems comprehensively. Integrated AC
& DC load bank could be made in one unit or separately with
different load voltages as per your need for different
applications.
Control Function:
Load testing: load power that not beyond the rated power, testing and display
stable state 3 phases voltage, current, active power, frequency,
working time, etc of generator sets.
Load/unload with one key: Whether manual control, remote control or software control, user
can preset the power, then press load master button. Load bank
loaded according to preset power to avoid load fluctuation during
the power changing.
Control Pattern: user can choose local control and intelligent control.
Local Control: There is local control panel with several power steps; user can
load/unload by button.
Intelligent Control: Through data processing software in PC, user
can make automatic load, to display, record and manage the testing
data, to form curves, tables, also to print them.
Control Pattern interlock, there is control pattern switch, when
choose one control pattern, operation of other pattern is invalid,
avoid the clash.
Local meter display data: local meter can display 3 phases voltage, current, active power,
frequency and so on.
Specification | |
Rating voltage | 600VDC |
Max Load Power | Power: 45kW |
Load Resolution | step:5KW |
Power Factor | 1 |
Load Tolerance (resistive load) | ±5% |
Load Tolerance (inductive load) | ±3% |
Fan Control Power | 110V/220V,50Hz/60Hz |
Wire Connection | Load bank input——Copper bar |
Control power input——Connector-bar | |
Max Protection Grade | IP56 |
Way of Working | Continuous Working |
Cooling | Forced air cooling, horizontal inlet air and upwards exhaust cooling |
Transportation | Hoisting |
Color | RAL7032 |
Dimensions | 750*800*1600 |
Weight | |
Accessories | Switch: ABB, Siemens and Schneider, PLC: Panasonic and Siemens; |
Operating Environment Parameter | |
Ambient Temperature | -10℃~+50℃ |
Relative Humidity | ≤95% |