Durable Rockwell Testing Machine , Ultrasonic Hardness Tester MHRS-150-P

Brand Name:Mitech
Certification:GB,JJG,ASTM...
Model Number:MHRS-150-P
Minimum Order Quantity:1 piece
Delivery Time:5-8 work days
Payment Terms:T/T, Western Union,PayPal
Contact Now

Add to Cart

Active Member
Location: Beijing Beijing China
Address: Room E506, YingChuangDongLi Park, 1# of ShangDi East Road, Haidian District, Beijing, China
Supplier`s last login times: within 35 hours
Product Details Company Profile
Product Details

Mitech MHRS-150-P Digital Plastic Rockwell Hardness Tester

Technical Parameters

Technical specificationsTechnical Parameters
Preliminary testing force98.07N,tolerance±2.0%
Testing force588.4N,980.7N,1471N,tolerance±1.0%
Measuring range

HRA:20-88,HRB:20-100,HRC:20-70,HRD:40-77,

HRE:70-100,HRF:60-100,HRG:30-94,HRH:80-100,

HRK:40-100,HRL:50-115,HRM:50-115,HRR:50-115

Testing force application modeAutomatic operation (preliminary test needs manual operation)
Indenter specificationΦ3.175mm steel ball indenter;Φ6.35mm steel ball indenter;Φ12.7mm steel ball indenter
DisplayLCD
Rockwell scaleHRA,HRB,HRC,HRD,HRE,HRF,HRG,HRH,HRK
Conversion scale

HRA,HRB,HRC,HRD,HR15N,HR30N,HR45N,

HR15T,HR30T,HR45T,HV,HK,HBW

Duration time1~30s(The testing force duration time for plastic Rockwell hardness test is 15 seconds)
Indication error0.1HR
Maximum height of specimen170mm
Distance of indenter to outer wall165mm
Power supplyAC220V/50Hz
Dimensions550*220*730mm
Main unit weight85kg

Indication Error

ScaleStandard Hardness RangeAllowed Maximum Tolerance
HRA20-75HRA±2HRA
75-88HRA±1.5HRA
HRB20-45HRB±4HRB
45-80HRB±3HRB
80-100HRB±2HRB
HRC20-70HRC±1.5HRC
HRD40-70HRD±2HRD
70-77HRD±1.5HRD
HRE70-90HRE±2.5HRE
90-100HRE±2HRE
HRF60-90HRF±3HRF
90-100HRF±2HRF
HRG30-50HRG±6HRG
50-75HRG±4.5HRG
75-94HRG±3HRG
HRH80-100HRH±2HRH
HRK40-60HRK±4HRK
60-80HRK±3HRK
80-100HRK±2HRK
HRL100-120HRL±1.2HRL
HRM85-110HRM±1.5HRM
HRR114-125HRR±1.2HRR

Working Principle

The Rockwell hardness test is taking the diamond cone with 120°apex angle or the hardened steel ball with specified diameter as the indenter to press into sample surface with specific test force, then get the Rockwell hardness of the measured metallic materials according to the sample surface indentation depth.

The Rockwell hardness measurement principle is shown as below figure. 0-0 is the position that the diamond indenter is not yet in contact with the sample. 1-1 figure is the indenter position under the affect of the preliminary test force, the indentation depth is h1. The preliminary test is to eliminate the influence to the testing result accuracy caused by the roughness of the sample surface. 2-2 in the figure is the indenter position under the influence of the testing force (the preliminary test force and the main test force). The depth is h2. 3-3 in the figure is the indenter position after dismounting the main test force. As the metal elasticity will recovery some degree after deformation, the really indentation depth of the indenter is h3. The plastic deformation caused by the main test force make the indenter pressing into the depth is h=h3-h1. Rockwell hardness value is determined by the size of h, the greater the depth h, the lower the hardness, otherwise, the higher the hardness.

In the traditional concept, usually use a constant C minus h to represent the level of hardness, while the depth of indentation per 0.002mm as a unit of hardness. The hardness value obtained is called the Rockwell hardness value, denoted by the symbol HR.


In the formula, c is a constant (for HRC, HRA, c is 0.2; for HRB, c is 0.26). The Rockwell hardness value HR obtained is an unknown number which is usually read directly on the test machine indicator when testing.

Rockwell hardness tester working principle Figure


It should be noted that the measured hardness values would be different with different indenter and test force. Therefore, the Rockwell hardness testing specifies 15 different hardness test scales according to the different indenter specification and test force sizes. And the HRB, HRC, HRA are the most widely used.

Features

  • Widely used for high-precision hardness testing for plastic, hard rubber, synthetic resin, friction material and softer metal;
  • Adopt electronic automatic operation system to control the testing force, easy to operate;
  • Option for various specifications of the indenter, support many types of Rockwell hardness scales testing ;
  • Equipped with high-speed thermal printer, quickly print out the test data;
  • Support the conversion among various hardness scales such as Brinell, Vickers and etc;
  • Adopt large-screen LCD, easy to operate, visually display the test results;
  • Equipped with excellent performance of the carbide indenter, high hardness, wear resistance, good toughness, meanwhile with high temperature and corrosion resistance to ensure that the instrument test value is accurate, stable and reliable;
  • With the function of threshold overrun automatic alarm, apply to the bulk of finished products or semi-finished pieces of paper-by-piece detection;
  • The function of original ambient temperature real-time display can avoid the instrument working in the case of high or low temperature for a long time , resulting in increased test error and reducing the service life;
  • Consistent with GB7407,JJG884,ASTMD785,GB/T 3398.2 other relevant standards at home and abroad.

The Scope of Application

ScaleIndenter typepreliminary testing forceTesting force (N)

Measuring

range

Application
A

Diamond

cone

98.07(N)588.4(N)20-88HRAhard alloy, carbide, surface quenched steel, carburizing steel
D980.7(N)40-77HRDthin steel sheet, surface quenched steel
C1471(N)20-70HRCquenched steel, tempered steel, chilled cast iron
F

Φ1.5875

1/16 inch steel ball


588.4(N)60-100HRFcast iron, aluminum, magnesium alloy, bearing alloy
B980.7(N)20-100HRBmild steel, copper alloy, annealed steel
G1471(N)30-94HRGphosphorus iron, beryllium bronze, malleable cast iron
H

Φ3.175

1/8inch steel ball


588.4(N)80-100HRHaluminum, zinc, lead etc.
E980.7(N)70-100HREbearing alloy, tin, hard plastics and other soft materials
K1471(N)40-100HRK
L

Φ6.35

1/4 inch steel ball

588.4(N)50-115HRLHard plastic ,hard rubber, aluminum, tin, bronze, mild steel, synthetic resin, friction materials and etc.
M980.7(N)50-115HRL
R

Φ12.7

1/2 inch steel ball

588.4(N)50-115HRL

Applications

  • Used for quality control in plastic products;
  • Used for resin rubber finished product testing
  • Demonstration experiment for education and teaching in Colleges and Universities;
  • Hardness testing of materials in scientific research institutions

Working Conditions

  • Operation Temperature:10~30℃;
  • Relative Humidity:≤65%;
  • The surrounding environment should avoid of vibration, strong magnetic field, corrosive medium and heavy dust.

Configurations

Configuration instructionsNO.NameQTY.Remarks

Standard configuration

1Main unit1
2

Φ3.175mm

1/8inch steel ball indenter

1Mainly used for measuring hard plastic and other non-metallic materials Rockwell hardness.
3

Φ6.35mm

1/4inch steel ball indenter

1
4

Φ12.7mm

1/2inch steel ball indenter

1
5Counterweights3
6Small testing table1Diameter 60mm
7Large testing table1Diameter 150mm
8V-shape testing table1Test cylindrical specimens
9Rockwell Standard Block4HRE,HRL,HRM,HRR
10Fuse 0.5A2
11Spare LED bulbs2
12Thermal printing paper1
13Power cable1
14Plastic dust cover1
15Attached files1
16ABS instrument case1

Maintenance and Precautions

  • The test personnel should follow the operating procedures.Before and after the test,it should be repeated with standard block calibration equipment;
  • If the specimen has visible deformation marks on the back and edges, the test result would be useless. It should choose the intender or test force to test again;
  • Normally, the first point is only used to offset the gap of each support surface without needing to record the test result. Record the statistical test result from the second point;
  • During testing, to ensure accuracy, please make sure the distance between the adjacent indentation center and the distance from the indentation center to edge of the specimen is greater than 3mm;
  • Pay attention to palm the instrument for carrying to forbid falling across. Please fix well the measuring lever, counterweight and boom before carrying;
  • It is strictly prohibited to turn the variable loading handwheel when the instrument load or unload the test force. Rotating the handwheel forcibly will cause the internal gear dislocation, test force in chaos and even damage the internal parts of the instrument;
  • Turn off the power after using the instrument;
  • When not in use for a long time, please cover the dust cover to prevent dust into the instrument interior. And the hardness block, indenter should be coated with antirust oil to prevent rusting after using;
  • Long time after the re-enabled,it should be preheated the electrical components before test
  • The hardness tester should be calibrated at least once a year to ensure its accuracy;
  • Don’t disassemble the instrument without authorization, for maintenance related matters, please contact MITECH after-sale service department with 4000600280.