Oil Analysis Testing Equipment ISO 3679 Automatic Low Temperature Closed Cup Flash Point Tester

Brand Name:SKYLINE
Certification:CE , Calibration Certificate
Model Number:SL-OA08
Minimum Order Quantity:1 Unit
Delivery Time:15 working days
Payment Terms:L/C, D/P, T/T, Western Union, MoneyGram
Contact Now

Add to Cart

Verified Supplier
Location: Dongguan Guangdong China
Address: No.1802 Room 6# Building Universal Commerce Center Nancheng District Dongguan Guangdong China
Supplier`s last login times: within 14 hours
Product Details Company Profile
Product Details

Low Temperature Fast Closed Cup Flash Point Tester (Equilibrium Method)

Product Introduction closed cup flash point tester

1. Full automatic closed cup flash point tester, used to measure the closed mouth flash point value of petroleum products.

2. Using 8-inch pure industrial true color touch screen, the Chinese and English interface can be switched at will,

3. Automatically correct the effect of atmospheric pressure on the test and calculate the correction value.

4. The lower computer stores 120 sets of historical data.

5. Ignition, printing, fully automatic.

6. Using imported Renesas MCU. Germany imported PT1000 high precision temperature sensor.

7. Built-in high-precision flash point detection sensor, detection time can reach milliseconds.

8. Simulation tracking shows the temperature rise as a function of test time,


Application

This instrument is especially suitable for testing the flash point of closed cups for various colored paints, paints, adhesives, solvents, petroleum and related products with a flash point in the range of -20 ℃ ~ + 80 ℃.


Technical parameters

1. working power: AC220V ± 10%, 50Hz;
2. Flash point detection range: (-20 ~ +100) ° C;
3. Measurement precision: The absolute difference between the two experimental results is less than 2 °C (same operator);
The absolute difference between the two experimental results is less than 3 ° C (different operators);
4. Temperature control accuracy: ± 0.5 ° C;
5. Ignition device: electronic ignition gun ignition;
6. cooling method: semiconductor refrigeration (external cold water circulator);
7. the power supply voltage: AC220V ± 10%, 50Hz;
8. Power consumption of the whole machine: no more than 300W;
9. the ambient temperature: 5 ° C ~ 30 ° C;
10. Relative humidity: (30~80)%.

Features

(1) Designed in accordance with GB / T 5208 "Determination of Flash Point, Quick Balance Closed Cup Method", to achieve the purpose of fast and low temperature test of closed cup flash point

(2) Using semiconductor refrigeration devices and external cooling water cooling devices, the instrument is small in size, fast in cooling speed and easy to use.

(3) There are few test samples, and only 2 ml is required for each injection (4 ml for solid or semi-solid samples).

(4) Except for ignition, the test process is completed automatically and the test results are printed automatically.


Please review the video of the Closed Mouth Flash Point Tester operation as below link:

https://youtu.be/FmxMemFId_4


China Oil Analysis Testing Equipment ISO 3679 Automatic Low Temperature Closed Cup Flash Point Tester supplier

Oil Analysis Testing Equipment ISO 3679 Automatic Low Temperature Closed Cup Flash Point Tester

Inquiry Cart 0