Central Air Conditioning Shell and Tube Heat Exchanger
Water Cooling Evaporator
The choose for shell and tube heat exchanger should be based on
fluid properties, from heat transfer,
reduced equipment corrosion, reduced pressure drop and easy
cleaning. In determining the factors
should be taken into account:
1. Corrosive media to take the pipe to avoid the shell when the
heat exchanger tube and shell at the same
time by the corrosion
2. Toxic medium to take the tube, the opportunity to leak less
3. High pressure medium to take the tube, so as not to increase the
thickness of the shell pressure, more
consumption of steel, the cost increases
4. Unclean easy to scale the media to take the tube, easy to clean,
shell is not easy to clean
5. Large viscosity or small flow of the tube, because the use of
multi-tube can be a larger flow rate, is
conducive to heat transfer
6. If the difference between the two media heat transfer
coefficient is large, it is necessary to transfer the
membrane heat transfer medium.
7. In the water cooler, the general water to go pipe, the cooling
medium to go shell
STRAIGHT SINGLE SERIES DRY SPIRAL BAFFLE PLATE EVAPORATOR
CAPACITY: 750KW TO 1500KW
Models | RE750S14 | RE900S16 | RE1100S16 | RE1240S20 | RE1360S20 | RE1420S20 | RE1500S20 | ||
Rated data ti=12°C te=2°C tu=7°C Dts=5°C | Qn | KW | 750 | 900 | 1100 | 1240 | 1360 | 1420 | 1500 |
Kcal/h(×103 ) | 700 | 862 | 983 | 1076 | 1169 | 1258 | 1367 | ||
Wn | m3 /h | 121 | 141 | 168 | 230 | 252 | 261 | 289 | |
Wm | m3 /h | 136 | 158 | 176 | 261 | 275 | 309 | 328 | |
Dpn | bar | 0.48 | 0.54 | 0.48 | 0.40 | 0.46 | 0.49 | 0.58 |
Models | RE750S14 | RE900S16 | RE1100S16 | RE1240S20 | RE1360S20 | RE1420S20 | RE1500S20 | |
Dimension(mm) | A | 170 | 170 | 170 | 190 | 190 | 190 | 190 |
B | 377 | 426 | 426 | 480 | 480 | 480 | 480 | |
C | 3000 | 2860 | 3000 | 2860 | 2860 | 3000 | 3500 | |
D | 460 | 530 | 530 | 600 | 600 | 600 | 600 | |
E | 400 | 450 | 450 | 500 | 500 | 500 | 550 | |
F | 3086 | 2984 | 3124 | 2984 | 2984 | 3124 | 3624 | |
Vent | S1 | 1/2 | 1/2 | 1/2 | 1/2 | 1/2 | 1/2 | 1/2 |
Outlet | S2 | 1/2 | 1/2 | 1/2 | 1/2 | 1/2 | 1/2 | 1/2 |
Connection | W(DN) | 150 | 150 | 150 | 200 | 200 | 200 | 200 |
D1(mm) | 42 | 42 | 42 | 54(2) | 54(2) | 54(2) | 54(2) | |
D2(mm) | 92 | 92 | 92 | 108 | 108 | 108 | 108 | |
P(kg) | 706 | 753 | 808 | 863 | 921 | 992 | 1069 | |