Multiple System SS316L Contracted Pipe Air Cooled Heat Exchanger

Brand Name:GREEFOUN
Certification:CE
Model Number:QXS45
Minimum Order Quantity:1piece
Delivery Time:within 15days
Payment Terms:T/T, L/C, Western Union
Contact Now

Add to Cart

Active Member
Location: Wuhan Hubei China
Address: No.18, Yinhu Development Zone, Dongxihu District Wuhan China
Supplier`s last login times: within 24 hours
Product Details Company Profile
Product Details

Multiple System Heat Pump Contracted Pipe Evaporator Patented Product For Air Cooled Unit Heat Exchanger


Many types of evaporators are used, and a large part of the evaporator is mainly used to cool the air, that


is, surface cooling evaporator; there are a small part of the evaporator used to cool the water, that is,


chillers.


1. Evaporator for cooling air (surface-cooled evaporator) 1) The working principle of surface-cooled


evaporator.


The process of surface-cooled evaporator is a vaporization endothermic process. Refrigerant after the


throttling process, a gas-liquid mixture, but the liquid accounted for the majority.


After the pressure of the refrigerant liquid flow in the evaporator, the intense heat-absorbing vaporization,


known as boiling, this step is to obtain the cooling effect of the thermal process, is the ultimate goal of the


refrigeration system, the process in the evaporator , After which the refrigerant becomes gaseous and


then compressed into the air condensation process.


The heat absorbed by the evaporator comes from two parts: the sensible heat released by the cooling air


and the latent heat released from the condensation of water vapor in the air.


In other words, the cooling capacity of the air conditioner is used to reduce the temperature of the air to


be cooled and the other for the condensation (dehumidification) of the water vapor in the air.


U SHAPED TUBE DRY EVAPORATOR (SINGLE CIRCUIT)


CAPACITY: 120KW TO 270KW


ModelsQXU120S8QXU135S8QXU155S8QXU185S10QXU220S10QXU270S10

Rated data

Refrigerant R22

ti=12°C te=2°C

tu=7°C Dts=5°C

QnKW120135155185220270
Kcal/h(×103 )103.2116133.3159180232
Wnm3 /h20.323.226.731.837.846.4
Wmm3 /h252830414365
Dpnbar0.410.440.370.360.430.42

ModelsQXU120S8QXU135S8QXU155S8QXU185S10QXU220S10QXU270S10
Dimension(mm)A181521152315232026542654
B219219219273273273
C180180180200234234
D153018302030200022802280
E240240240300300300
VentS11/21/21/21/21/21/2
OutletS21/21/21/21/21/21/2
ConnectionW(DN)808080100100100
D1(mm)353535353535
D2(mm)545467678080
P(kg)145155163232279289

Qn-rated refrigerating capacity Wn-cooling water flow Wm-maximum cooling water flow

Dpn-pressure drop of recirculating cooling water Dts-overheat temperature


U SHAPED TUBE DRY EVAPORATOR (DOUBLE CIRCUIT)


CAPACITY: 120KW TO 310KW


ModelsQXU120D8QXU135D8QXU155D8QXU185D10QXU220D10QXU270QXU310

Rated data

Refrigerant R22

ti=12°C te=2°C

tu=7°C Dts=5°C

QnKW120135155185220270310

Kcal/h

(×103 )

103.2116133.3159189232267
Wnm3 /h20.623.226.731.837.846.453.3
Wmm3 /h25283041436568
Dpnbar0.410.440.370.360.430.420.43

ModelsQXU120D8QXU135D8QXU155D8QXU185D10QXU220D10QXU270QXU310

Dimension

(mm)

A1815211523152320232026542654
B219219219219273273273
C200200200200234234234
D1530183020302000200022802280
E240240240300300300300
VentS11/21/21/21/21/21/21/2
OutletS21/21/21/21/21/21/21/2
ConnectionW(DN)89898989114114114
D1(mm)22222222353535
D2(mm)42424242545454
P(kg)145155163232255279296

Qn-rated refrigerating capacity Wn-cooling water flow Wm-maximum cooling water flow

Dpn-pressure drop of recirculating cooling water Dts-overheat temperature


CONDENSER SERIES SINGLE CIRCUIT


CAPACITY: 40RT TO 70RT


ModelRefrig. ton (RT)Refrig. ton (104kcal/h)Dimension (mm)Weight (kg)Max. water flow
DT1TACEH1H2
QXC40S10A4015.122731600205312036015035024020431
QXC45S10A4517.012731600205312036015035024021235
QXC50S10A5018.902732032248512036015035024024038.5
QXC55S10A5520.792732032248512036015035024024942.5
QXC60S10A6022.682732032248512036015035024025646
QXC65S10A6524.572732032248512036015035024026449.2
QXC70S10A7026.462732032248512036015035024027053.5

ModelS (Vent)

P (fluoride inlet)

Copper pipe diameter (inch)

L(fluoride outlet)

Copper pipe diameter (inch)

W (standard port)W (optional port)
FPT(inner pipe thread)Male flangeMale flange
QXC40S10A3/81-5/81-1/8DN65DN65
QXC45S10A3/81-5/81-1/8DN65DN65
QXC50S10A3/81-5/81-1/8DN65DN80
QXC55S10A3/81-5/81-1/8DN65DN80
QXC60S10A3/81-5/81-3/8DN65DN80
QXC65S10A3/81-5/81-3/8DN65DN80
QXC70S10A3/82-1/81-3/8DN80DN80

CONDENSER SERIES DOUBLE CIRCUIT


CAPACITY: 10RT TO 40RT


ModelRefrig. ton (RT)Refrig. ton (104kcal/h)Dimension (mm)Weight (kg)Max. water flow
DT1TACC2E
QXC10D6103.7816848310657518523392787.8
QXC15D6155.67168635136975185233928511.6
QXC20D6207.56168819173790185233929615.8
QXC25D6259.4521981917559023828511313219.5
QXC30D63011.3421981917559023828511313723
QXC35D63513.2321981917559023828511314527.3
QXC40D64015.1221995320249023828511316231

ModelS (Vent)

P (fluoride inlet)

Copper pipe diameter (inch)

L(fluoride outlet)

Copper pipe diameter (inch)

W (standard port)
FPT(inner pipe thread)FPT(inner pipe thread)
QXC10D61/45/85/81-1/2
QXC15D61/47/85/81-1/2
QXC20D61/47/85/81-1/2
QXC25D61/41-1/87/82
QXC30D61/41-1/87/82-1/2
QXC35D61/41-3/87/82-1/2
QXC40D61/41-3/87/82-1/2

COMPANY IMAGE



COOPERATED CLENTS

China Multiple System SS316L Contracted Pipe Air Cooled Heat Exchanger supplier

Multiple System SS316L Contracted Pipe Air Cooled Heat Exchanger

Inquiry Cart 0